High Speed Centrifuge is a microprocessor-controlled unit with automatic rotor recognition and imbalance detection. Features 18500 rpm of maximum speed with 26019×g of RCF to perform wide range of separations. Designed with double layered steel structure with double lid and lock system, has brushless drive for smooth and quiet operation.

Applications

High speed centrifuge is used to acquire rapid precipitation of the sample, extract serum from blood, microcell separation, microbiological sample treatment, PCR experimental zone centrifugation across laboratories, research, forensics etc.

Specifications

Maximum capacity12×10 ml
Maximum speed18500 rpm
Maximum RCF26019×g
Speed precision± 20 rpm
Timing range1 sec to 999 min
Acceleration/Deceleration15 types
Memory20 programs
DisplayLED
ControllerMicroprocessor
Noise≤ 60 dB
Power supplyAC 110/220 V, 50/60 Hz
Dimension (W×D×H)330×390×325 mm
Packaging dimension (W×D×H)480×415×470 mm
Net weight28 kg
Gross weight30 kg

Features

A microprocessor controlled high speed centrifuge

Automatic rotor recognition and imbalance detection

Double layered steel structure with anti-corrosion coating

Double lid and lock system for safe and reliable operation

Maintenance free brushless drive for smooth and quiet operation

Allows parameter revision during running operation

Audible alarm system for imbalance and error during operation

Short spin function with shortest acc/dec time of <30 sec

LED display for convenient setting and monitoring of parameters

FAQ

Q1: What is the maximum rotational speed of this centrifuge?
A1: The maximum speed is 15000 RPM (varies by model), such as 15000 RPM for high-speed models and 4000 RPM for low-speed models.

Q2: Does it have a refrigeration function?
A2: No, it is a non-refrigerated centrifuge - Refrigerated models can maintain a temperature range of -20°C to 40°C, while non-refrigerated models operate at ambient temperature.

Q3: What is the maximum capacity of the rotor?
A3: The standard rotor can hold 12×15ml test tubes (e.g., 12×15ml test tubes), and optional rotors are available for different tube sizes.

Q4: How to ensure the safety of centrifugation operation?
A4: It is equipped with multiple safety protections, including imbalance detection, door lock protection, and over-temperature/over-speed protection.

Q5: What is the recommended maintenance cycle?
A5: It is recommended to clean the rotor and chamber after each use, and perform a comprehensive maintenance check every 6 months (or 500 operating hours).

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.