Introduction
High Speed Centrifuge is a microprocessor-controlled unit with automatic rotor recognition and imbalance detection. Features 18500 rpm of maximum speed with 26019×g of RCF to perform wide range of separations. Designed with double layered steel structure with double lid and lock system, has brushless drive for smooth and quiet operation.
Applications
High speed centrifuge is used to acquire rapid precipitation of the sample, extract serum from blood, microcell separation, microbiological sample treatment, PCR experimental zone centrifugation across laboratories, research, forensics etc.
Specifications
| Maximum capacity | 12×10 ml |
| Maximum speed | 18500 rpm |
| Maximum RCF | 26019×g |
| Speed precision | ± 20 rpm |
| Timing range | 1 sec to 999 min |
| Acceleration/Deceleration | 15 types |
| Memory | 20 programs |
| Display | LED |
| Controller | Microprocessor |
| Noise | ≤ 60 dB |
| Power supply | AC 110/220 V, 50/60 Hz |
| Dimension (W×D×H) | 330×390×325 mm |
| Packaging dimension (W×D×H) | 480×415×470 mm |
| Net weight | 28 kg |
| Gross weight | 30 kg |
Features
A microprocessor controlled high speed centrifuge
Automatic rotor recognition and imbalance detection
Double layered steel structure with anti-corrosion coating
Double lid and lock system for safe and reliable operation
Maintenance free brushless drive for smooth and quiet operation
Allows parameter revision during running operation
Audible alarm system for imbalance and error during operation
Short spin function with shortest acc/dec time of <30 sec
LED display for convenient setting and monitoring of parameters
FAQ
Q1: What is the maximum rotational speed of this centrifuge?
A1: The maximum speed is 15000 RPM (varies by model), such as 15000 RPM for high-speed models and 4000 RPM for low-speed models.
Q2: Does it have a refrigeration function?
A2: No, it is a non-refrigerated centrifuge - Refrigerated models can maintain a temperature range of -20°C to 40°C, while non-refrigerated models operate at ambient temperature.
Q3: What is the maximum capacity of the rotor?
A3: The standard rotor can hold 12×15ml test tubes (e.g., 12×15ml test tubes), and optional rotors are available for different tube sizes.
Q4: How to ensure the safety of centrifugation operation?
A4: It is equipped with multiple safety protections, including imbalance detection, door lock protection, and over-temperature/over-speed protection.
Q5: What is the recommended maintenance cycle?
A5: It is recommended to clean the rotor and chamber after each use, and perform a comprehensive maintenance check every 6 months (or 500 operating hours).