Introduction
Fluorescence biological microscope is a bench-top unit integrated with digital display for viewing. Optical systems include wide field high eyepieces and florescent achromatic objectives. Built in high resolution florescent objectives aids to achieve excellent florescent image. Coaxial coarse and fine adjustment focus knob with tension adjustment helps with mobility of the objective lenses.
Applications
Used in biological, histological, pathological, bacteriology, immunizations and pharmacy field. Widely used in medical institutes, laboratories, academic laboratories and colleges.
Specifications
| Viewing head | Seidentopf trinocular |
| Eyepiece (Extra wide field) | EW10X / 22 mm |
| Inclination | 30° |
| Eyepiece tube diameter | 30 mm |
| Inter-pupillary distance | 48 mm ⁓ 75 mm |
| Rotation | 360° |
| Plan achromatic objective | 4X 10X 40X 100X |
| Focus fine division | 0.002 mm |
| Coarse stroke | 37.7 mm per rotation |
| Fine stroke | 0.2 mm per rotation |
| Moving range | 22 mm |
| Condenser | Abbe Condenser NA1.25 |
| Stage | Rectangular 216 mm × 150 mm Cross Travel 78 mm × 54 mm |
| Lamp | 100 W |
| Illumination | 12 V / 20 W |
| Power supply | 220 V ⁓ 110 V |
| Dimensions | 380 × 270 × 510 mm |
| Weight | 10 kg |
Features
Rotatable Seidentopf trinocular view head
Mechanical rectangular stage ( X-Y coaxial control knob )
Backward quintuple nosepiece
Ultra Hi-voltage spherical mercury lamp
Abbe condenser with aperture diaphragm
Filters : Excitation, barrier and dichromatic mirror
Ergonomic design ( more comfortable viewing )
FAQ
Q1: What is the magnification range of this microscope?
A1: The magnification range is 40× to 1000× (e.g., 40× to 1000× for biological microscopes), with replaceable objectives for different observation needs.
Q2: Does it support digital imaging?
A2: No, but supports optional digital camera installation - Some models are equipped with a digital camera interface, which can be connected to a computer for image capture and analysis.
Q3: How to adjust the focus for clear observation?
A3: It has coarse and fine adjustment knobs. First use the coarse adjustment to find the sample, then use the fine adjustment to get a clear image.
Q4: What type of light source does it use?
A4: It adopts a LED light source, which has long service life (up to 50000 hours) and stable brightness, without frequent bulb replacement.
Q5: Is the microscope easy to maintain?
A5: Regular maintenance only requires wiping the lenses with lens paper and keeping the stage clean. Avoid touching the lens surface with fingers.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.