Introduction
A glass liquid separator is a laboratory apparatus used for the separation of the immiscible liquids, such as the oil and the water, by the gravity separation, and it is used in the chemistry, the biology, the pharmaceutical, and the many other laboratories. The glass liquid separator consists of a glass vessel with the graduated scale, an inlet and an outlet, and a stopcock at the bottom, and it separates the liquids by the settling, with the heavier liquid drained from the bottom through the stopcock; the glass liquid separator is used for the separation of the immiscible liquids, for the separation of the phases in the extraction, for the collection of the separated liquids, and for many other applications, and it is available in various volumes; the glass liquid separator is an essential equipment for the liquid-liquid separation. Glass liquid separators are used in the chemistry laboratories, in the biology laboratories, in the pharmaceutical industry, in the research, and for many other applications. With their gravity separation, glass liquid separators are essential for the phase separation.
Glass Liquid Separator LGLS-T2014
Glass features a 100 L working volume, enabling effective liquid-liquid extraction in high-capacity setups. Its frequency-controlled stirring adjusts speed dynamically to enhance materia...
Glass Liquid Separator LGLS-T2013
Glass offers a 50 L volume which is ideal for larger batch phase separations in lab processes. Its stainless-steel frame resists chemical corrosion, ensuring long-term durability during ...
Glass Liquid Separator LGLS-T2012
Glass features a 30 L capacity that supports effective separation in medium-scale laboratory processes. The overload-protected motor maintains consistent operation by preventing heat bui...
Glass Liquid Separator LGLS-T2011
Glass with a 20 L volume capacity supports continuous liquid-liquid separation in stirred batch operations. Its ceramic bearing system minimizes wear, ensuring smooth rotation during pro...
Glass Liquid Separator LGLS-T2010
Glass with 10 L capacity supports controlled liquid-liquid extraction during mixing. It uses frequency conversion speed control to enhance contact between liquids, ensuring uniform agita...
Standards
ISO 3819:2015-Laboratory glassware-Beakers
ISO 4787:2021-Laboratory glass and plastic ware-Volumetric instruments-Methods for testing of capacity and for use
Complies with the above standards, but is not limited to them.
Features
1. Glass liquid separator for phase separation.
2. Glass vessel separating immiscible liquids.
3. For chemistry and extraction.
4. Includes separator, stopcock and fittings.
5. Separates liquid phases by density.
FAQ
Q1: What scenarios is this separator used for?
A: It separates immiscible liquid phases by density in a glass vessel with a stopcock for extraction and chemistry.
Q2: What standards does it comply with?
A: It follows standard laboratory glassware practices and related GB/T standards. We confirm the stated performance during final inspection and can supply a certificate of conformity together with supporting documents for audit purposes.
Q3: What is the warranty?
A: Glassware is fragile; defects on arrival are covered, while breakage in use is excluded. We replace items damaged in transit and can help plan stock levels so replacements remain available when needed.
Q4: Is it hard to operate?
A: It requires trained staff for extraction and venting. We provide guidance. A quick-start guide is included, and short remote guidance from our support team is available if your staff require it.
Q5: What is the lead time?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is calibration required?
A: No formal calibration is required, but the seals and moving parts should be inspected and verified periodically to ensure there are no leaks. This functional check takes only a moment and should be recorded in the maintenance log. Replacement parts and service support are available from us if wear is found.
Q7: Are consumables universal?
A: These are disposable consumables and should be replaced after use to avoid cross-contamination. They are standard laboratory items available directly from us or from general laboratory suppliers, which keeps running costs low. We recommend keeping a small stock, and bulk pricing is available for regular orders.
Q8: Can it be customized?
A: Yes, several configurations are available. Options include volume and jacketed versions. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.
Q9: Is installation included?
A: No installation is required for this unit. It is ready to run after a simple power connection and the leveling steps shown in the manual. We supply a detailed operation guide and online setup videos, and on-site commissioning can be arranged separately if your facility requires it.
Q10: What liquids are compatible?
A: It handles immiscible liquids compatible with glass. It is not for emulsions that do not separate, hydrofluoric acid, or pressures beyond glass limits.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.