Introduction

An ELISA analyzer is a laboratory instrument used to perform and read enzyme-linked immunosorbent assay (ELISA) tests, which are used to detect and quantify substances, such as antibodies, antigens, proteins, and hormones, in biological samples, and it is used in clinical diagnostics, immunology, food testing, veterinary diagnostics, and research. The ELISA test is performed in microplates, typically with 96 wells, in which the sample and the reagents are added, and the antigen-antibody reaction produces a color change, and the absorbance of the color is proportional to the concentration of the analyte; the ELISA analyzer consists of a microplate reader, which measures the absorbance of the wells at specific wavelengths, and may include a washer and an incubator, which automate the washing and incubation steps, and software for the analysis of the results; the analyzer reads the microplate and calculates the concentrations of the analytes using calibration curves, and it provides rapid and automated results, with features such as multi-wavelength reading, shaking, and data management, and it is used with ELISA kits for various analytes, and it can process many samples, with a high throughput; the ELISA analyzer is used for hormone testing, for the detection of infectious diseases, for allergen testing, for food contaminant testing, and for many other applications. ELISA analyzers are used in hospital and clinical laboratories, in blood banks, in veterinary laboratories, in food testing laboratories, in pharmaceutical research, and for many other applications. With their automated reading of ELISA tests, ELISA analyzers are essential for immunoassay testing.

ELISA Analyzer LELISA-T2010

ELISA Analyzer LELISA-T2010



Analyzer is an automated unit consisting of a single sampling channel with a capacity ranging from 10µl to 1000µl. It features 8 independent photometric channels with both mono and di...
ELISA Analyzer LELISA-T2011

ELISA Analyzer LELISA-T2011



Analyzer features a photometric microplate reader with 8 channels, using silicon photodiode detectors and a tungsten halogen lamp, covering 340 to 750 nm wavelength range. It uses a sin...

Standards

IEC 61010-2-101:2018-Particular requirements for in vitro diagnostic (IVD) medical equipment

IEC 61010-2-081:2015-Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes

Complies with the above standards, but is not limited to them.

Features

1. ELISA analyzer for processing ELISA microplates.

2. Automated plate washer, reader or integrated ELISA system.

3. For immunology, clinical and research laboratories.

4. Includes analyzer, software, accessories and manual.

5. Reads or processes ELISA plates consistently.

FAQ

Q1: What scenarios is this analyzer used for?

A: It reads or processes ELISA plates for immunology, clinical and research assays, automating washing or absorbance reading for consistent results.

Q2: What standards does it comply with?

A: It follows laboratory equipment safety and related GB/T standards, with optical performance and plate handling verified. Final inspection verifies these parameters before delivery, and the supporting compliance records are available when the order is placed.

Q3: What is the warranty?

A: The analyzer carries a 12 to 24 month warranty covering the instrument. Lamps are wear parts. Damage from spills or misuse is excluded.

Q4: Is it hard to operate?

A: Operation requires trained staff for plate setup and interpretation. We provide a manual, installation and training.

Q5: What is the lead time?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is calibration required?

A: We recommend verification against traceable standards at regular intervals, typically every 6 to 12 months, and keeping calibration records for audit purposes. The manual describes the procedure, and reference standards are available from us. Accredited third-party calibration can also be arranged on request.

Q7: Are consumables universal?

A: Plates and reagents are standard ELISA supplies, while parts are model-specific. Ongoing cost includes plates and reagents.

Q8: Can it be customized?

A: Yes, several configurations are available. Options include reader, washer or integrated systems, data systems and LIMS connectivity. We can discuss further custom requirements, confirm feasibility and advise any effect on the schedule before the order is confirmed.

Q9: Is installation included?

A: No installation is required. The unit is delivered fully assembled and factory tested, so you only need to place it on a level surface, connect power and follow the quick-start guide. An illustrated manual and setup video are included, and our engineers provide remote guidance if needed.

Q10: What plates are compatible?

A: It handles standard microplates within format. It is not for non-standard plates, non-optical assays, or samples beyond the plate format.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.