Introduction

An automatic slide stainer is a staining instrument with the automatic operation, used for the staining of the slides with the biological specimens, and it is used in the pathology, the histology, the clinical, and the many other applications. The automatic slide stainer performs the staining protocols automatically, such as the hematoxylin and the eosin (H&E) staining and the special staining, and it processes the multiple slides in the batches, with the consistent and the reproducible staining; the automatic slide stainer consists of the slide racks, the reagent containers, a fluid delivery system, the staining stations, a control system, and the display, and it provides features such as the programmable protocols; the automatic slide stainer is used for the staining of the tissue sections and the cytology slides, for the H&E staining, for the special staining, for the pathology, and for many other applications, and it is an essential instrument in the histology laboratory. Automatic slide stainers are used in the pathology, in the histology, in the clinical laboratories, in the research, and for many other applications. With their automatic operation, automatic slide stainers are essential for the consistent staining.

Automatic Slide Stainer LASS-T2041

Automatic Slide Stainer LASS-T2041



Automatic Slide Stainer is a fully automated staining system designed for high-throughput histopathology laboratories. It supports up to 720 slides per hour for consistent staining resul...
Automatic Slide Stainer LASS-T2040

Automatic Slide Stainer LASS-T2040



Automatic Slide Stainer features three staining racks, each capable of holding 20 slides, and supports an infinite loop working mode. Its dyeing rack features an automated identification...
Automatic Slide Stainer LASS-T2030

Automatic Slide Stainer LASS-T2030



Automatic Slide Stainer can process up to 65 tissue samples in a single cycle, with each cylinder holding 1000 mL of reagent. It features a color touch screen with an -style interface, m...
Automatic Slide Stainer LASS-T2020

Automatic Slide Stainer LASS-T2020



Automatic Slide Stainer can process at least 200 specimen slides per hour, depending on the selected staining program. It is equipped with advanced a control system and a user-friendly e...
Automatic Slide Stainer LASS-T2011

Automatic Slide Stainer LASS-T2011



Automatic Slide Stainer handles up to 45 slides for effective and uniform staining. It supports 18 reagent tanks, each with a 1000 mL capacity for uninterrupted operation. The system pro...
Automatic Slide Stainer LASS-T2010

Automatic Slide Stainer LASS-T2010



Automatic Slide Stainer is an electrically designed Automated Slide Stainer with a dyeing frame capacity of 30 slides. Dyeing procedures can be displayed on the operation interface in re...

Standards

ISO/TS 23824:2024-Medical laboratories-Guidance on application of ISO 15189 in anatomic pathology

ISO 15189:2022-Medical laboratories-Requirements for quality and competence

Complies with the above standards, but is not limited to them.

Features

1. Automatic slide stainer for automated histological slide staining.

2. Programmable staining for H&E, special stains and immunohistochemistry.

3. Suitable for pathology, histology, clinical, research and educational laboratories.

4. Includes slide mechanism, reagent stations, controller, software and operation manual.

5. Supports automated staining for consistent, high-throughput histology processing.

FAQ

Q1: What testing scenarios is this stainer mainly applied to?

A: The automatic slide stainer is used in pathology laboratories, histology facilities, clinical diagnostics, research institutions, pharmaceutical development and educational settings to perform automated staining of tissue slides for histopathological diagnosis, research and education. It supports routine H&E (hematoxylin and eosin) staining for diagnostic pathology, special stains (PAS, Masson trichrome, Gram, Ziehl-Neelsen, reticulin) for specific tissue components, immunohistochemistry (IHC) staining for biomarker analysis, high-throughput clinical pathology, pharmaceutical tissue analysis, and research staining. The automated system provides consistent, reproducible staining results with reduced operator variability, supporting efficient, standardized histology processing in diagnostic and research laboratories.

Q2: What standards does the stainer comply with?

A: The automatic slide stainer complies with relevant IEC 61010 laboratory electrical safety standards, IEC 61674 for medical electrical equipment (clinical use), applicable GB/T standards for histological equipment, and relevant medical device regulations (FDA, CE, NMPA). The instrument follows applicable electromagnetic compatibility standards. Reagents and stains should be from qualified suppliers. Clinical use follows applicable laboratory accreditation requirements (ISO 15189, CAP, CLIA).

Q3: What is the warranty period for the whole machine and key components?

A: The whole automatic slide stainer is covered by a 12-month warranty. The slide mechanism, reagent delivery, controller, software and housing are covered, while reagents, slides, tubing and fuses are consumables. Damage from improper use, reagent spills or unauthorized repair is excluded. Extended service contracts are available for this clinical laboratory equipment.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires trained histology or pathology personnel familiar with automated staining and immunohematology. We provide comprehensive training, operation manuals and application support. Proper slide loading, reagent setup, protocol programming, stain quality monitoring, maintenance and biosafety procedures are critical for consistent results and patient safety.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Staining quality verification with control slides recommended per run for clinical use. Reagent level and condition checked per schedule. Mechanism and fluidics verified periodically. Software updates installed as needed. Full system performance verification annually. Routine cleaning of reagent stations and fluidics recommended.

Q7: Are supporting consumables universal?

A: Stains, reagents, slides, coverslips and tubing are available from histology suppliers, though instrument-specific parts should be verified. Long-term consumable cost depends on staining volume and reagent choices.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes slide capacity, staining protocols, reagent station number, IHC capability, software features, LIS connectivity and accessories. Additional reagent kits and accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Yes, automatic slide stainers include on-site installation, commissioning, protocol setup and operator training by certified specialists. Site preparation guidance is provided before delivery.

Q10: What types of slides are compatible with this equipment?

A: The automatic slide stainer stains prepared tissue slides (fixed, paraffin-embedded sections mounted on slides) within the slide capacity, protocol and reagent specification. Different staining methods (H&E, special stains, IHC) require specific reagents and protocols. Slides should be properly prepared (deparaffinized, rehydrated) before staining. Users should load slides properly, use appropriate reagents for the staining method, program correct protocol timings, include control slides for quality monitoring, follow proper biosafety procedures for chemical reagents and patient samples, and maintain proper documentation per clinical laboratory requirements. The stainer should be cleaned regularly to prevent reagent cross-contamination and buildup. For clinical pathology, staining quality should be monitored per laboratory accreditation requirements, and control slides should be included in each staining run. The instrument should be used per manufacturer instructions for fluidics maintenance and reagent replacement. For IHC staining, follow proper antigen retrieval, antibody incubation and detection protocols. The stainer should be placed in a well-ventilated area due to chemical reagent fumes (xylene, alcohols). Waste should be disposed of per chemical and biological waste regulations. For high-throughput clinical use, proper workflow management and result tracking should be established.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.