Introduction

A chemiluminescence imaging system is an instrument used for the detection and the imaging of the chemiluminescence signals, which are used for the detection of the proteins, the nucleic acids, and the other biomolecules, and it is used in the biology, the clinical, the research, and the many other applications. The chemiluminescence imaging system detects the light emitted by the chemiluminescent reactions, such as the horseradish peroxidase (HRP) and the alkaline phosphatase (AP) labeled assays, and it captures the images with a cooled charge-coupled device (CCD) camera; the chemiluminescence imaging system consists of a dark cabinet, a cooled CCD camera, the lenses, a sample stage, and the software, and it provides the images, with features such as the quantitative analysis and the image processing; the chemiluminescence imaging system is used for the western blotting, for the detection of the proteins, for the detection of the nucleic acids, for the enzyme-linked immunosorbent assay (ELISA), for the research, for the diagnostics, and for many other applications, and it is an essential instrument for the chemiluminescence detection. Chemiluminescence imaging systems are used in the biology laboratories, in the clinical laboratories, in the research, and for many other applications. With their chemiluminescence detection, chemiluminescence imaging systems are essential for the sensitive detection.

Chemiluminescence Imaging System LCIS-T2011

Chemiluminescence Imaging System LCIS-T2011



Chemiluminescence Imaging System captures high-resolution images at up to 6.0 megapixel. Equipped with customizable filter set for various wavelengths of emissions. Its multi-exposure fe...
Chemiluminescence Imaging System LCIS-T2010

Chemiluminescence Imaging System LCIS-T2010



Chemiluminescence Imaging System features a high-resolution camera with 16-bit depth. It provides excellent sensitivity for detecting low-level chemiluminescent signals in samples. The s...
Chemiluminescence Imaging System LCIS-T2022

Chemiluminescence Imaging System LCIS-T2022



Chemiluminescence Imaging System is a new generation, an integrated device with 10.1-inch touch screen display, for used for imaging Chemiluminescence Gel with exceptionally high quantum...
Chemiluminescence Imaging System LCIS-T2023

Chemiluminescence Imaging System LCIS-T2023



Chemiluminescence Imaging System is a new generation, an integrated device with 10.1-inch touch screen display, for used for imaging Chemiluminescence Gel with exceptionally high quantum...
Chemiluminescence Imaging System LCIS-T2021

Chemiluminescence Imaging System LCIS-T2021



Chemiluminescence Imaging System is a new generation, an integrated device for used for imaging Chemiluminescence Gel with exceptionally high quantum efficiency Camera for greater sensit...
Chemiluminescence Imaging System LCIS-T2020

Chemiluminescence Imaging System LCIS-T2020



Chemiluminescence Imaging System is a new generation, an integrated device for used for imaging Chemiluminescence Gel with exceptionally high quantum efficiency Camera for greater sensit...

Standards

Complies with the above standards, but is not limited to them.

Features

1. Chemiluminescence imaging system for detecting and imaging chemiluminescent signals.

2. High-sensitivity cooled CCD camera for low-light chemiluminescence detection.

3. Suitable for molecular biology, Western blot, protein, nucleic acid and research labs.

4. Includes dark chamber, cooled CCD camera, lens, software and operation manual.

5. Supports Western blot imaging, EMSA, reporter gene and chemiluminescent assays.

FAQ

Q1: What testing scenarios is this system mainly applied to?

A: The chemiluminescence imaging system is used in molecular biology, protein research, nucleic acid analysis, cell biology, pharmaceutical development and research to detect and image chemiluminescent signals from Western blots, EMSA gels, reporter gene assays and other chemiluminescent applications using a high-sensitivity cooled CCD camera in a dark chamber. It supports Western blot protein detection and quantification, EMSA (electrophoretic mobility shift assay) imaging, reporter gene (luciferase) assay imaging, nucleic acid detection with chemiluminescent probes, protein array imaging, and general low-light chemiluminescence detection. The cooled CCD camera provides high sensitivity for detecting faint chemiluminescent signals, enabling quantitative analysis of protein and nucleic acid samples. It is essential for molecular biology, protein, nucleic acid, pharmaceutical and research laboratories requiring chemiluminescence detection and imaging for Western blot analysis, EMSA, reporter gene assays, protein arrays and low-light detection, where the high-sensitivity cooled CCD camera in a dark chamber provides sensitive, quantitative imaging of chemiluminescent signals, supporting protein expression analysis, nucleic acid research, drug development and molecular biology applications requiring reliable, high-sensitivity chemiluminescence detection and quantification.

Q2: What standards does the system comply with?

A: The chemiluminescence imaging system complies with relevant IEC 61010 laboratory electrical safety standards and applicable GB/T standards for laboratory imaging equipment. Molecular biology and research applications follow good laboratory practice. The system complies with relevant electromagnetic compatibility standards. For quantitative analysis, proper calibration and linearity verification should be performed. Users should verify compatibility with their specific assays and sample types.

Q3: What is the warranty period for the whole machine and key components?

A: The whole imaging system is covered by a 12-month warranty. The cooled CCD camera, lens, dark chamber, controller and software are covered, while calibration standards and fuses are consumables or accessories. Damage from improper use, camera damage or unauthorized repair is excluded. Extended service contracts are available for this specialized imaging equipment.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires trained molecular biology personnel familiar with chemiluminescent assays, imaging and data analysis. We provide comprehensive training, operation manuals and application support. Proper sample preparation, assay protocol, camera settings, exposure time, image analysis and quantification are important for reliable results.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Camera calibration and linearity verification recommended every 6-12 months. Dark current and noise checked periodically. Lens and chamber condition verified. Routine cleaning of camera and chamber. Software updates installed as available. Full system performance verification annually.

Q7: Are supporting consumables universal?

A: Calibration standards, blotting membranes and reagents are available from molecular biology suppliers, though camera-specific calibration should use manufacturer-recommended standards. Long-term consumable cost depends on experiment volume and reagent choices.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes CCD camera resolution and sensitivity, lens, dark chamber size, multi-channel capability, fluorescence option, software features and automation. Additional accessories and software modules can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Yes, chemiluminescence imaging systems include on-site installation, commissioning, calibration and operator training by certified imaging specialists. Site preparation guidance is provided before delivery to ensure environmental and space requirements are met.

Q10: What types of samples are compatible with this equipment?

A: The chemiluminescence imaging system images chemiluminescent samples including Western blots (membranes), EMSA gels, reporter gene assays, protein arrays and other chemiluminescent samples within the chamber size, sensitivity and dynamic range specification. Different assays require specific chemiluminescent substrates and protocols. The sample should be properly prepared and the signal within the camera dynamic range. Users should follow proper assay protocols for chemiluminescent detection, optimize exposure time for signal intensity, use proper image analysis software for quantification, include appropriate controls and standards, avoid light exposure of chemiluminescent samples before imaging, and maintain the dark chamber light-tightness. For quantitative Western blot, proper loading controls and linear range verification are important. The cooled CCD camera should be allowed proper cooling before imaging, and the system should be placed in a low-vibration, temperature-stable environment for optimal performance. Images should be saved in uncompressed format for quantitative analysis, and image manipulation should be documented per publication guidelines.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry