Introduction

A UV pass box with HEPA filters is a pass-through chamber used in cleanrooms and controlled environments for transferring materials between areas of different cleanliness levels, and it is equipped with UV lamps for surface decontamination and HEPA filters for air filtration, and it is used in pharmaceutical, biotechnology, electronics, and laboratory facilities. The pass box consists of an enclosed chamber with interlocking doors on both sides, so that only one door can be opened at a time, preventing the direct exchange of air between the two areas; the UV lamps inside the chamber decontaminate the surfaces of the materials placed in the box, reducing the microbial load, and the HEPA filters provide filtered air or exhaust to maintain the cleanliness of the box and to remove particles, and the interlocking doors and the air handling system maintain the pressure and cleanliness differential between the areas. UV pass boxes with HEPA filters are used for transferring materials, components, samples, and equipment into and out of cleanrooms, clean benches, isolators, and other controlled environments, and they are used in pharmaceutical manufacturing, in microbiology and cell culture laboratories, in semiconductor and electronics manufacturing, and in other industries where contamination control is critical, and they are available in various sizes, with features such as UV lamps with timers, HEPA filters, interlocking doors, and stainless steel construction. With their decontamination and filtration capabilities, UV pass boxes with HEPA filters are essential for contamination control in clean environments.

UV Pass Box (with HEPA filters) LUP-T2011

UV Pass Box (with HEPA filters) LUP-T2011



UV Pass Box (with filters) provides sterile air flow, is equipped with advanced both side electrical interlocked doors, high quality glass window, and UV lamp. Made up of high quality 30...
UV Pass Box (with HEPA filters) LUP-T2012

UV Pass Box (with HEPA filters) LUP-T2012



UV Pass Box (with filters) provides sterile air flow, is equipped with advanced both side electrical interlocked doors, high quality glass window, and UV lamp. Made up of high quality 30...
UV Pass Box (with HEPA filters) LUP-T2010

UV Pass Box (with HEPA filters) LUP-T2010



UV Pass Box (with filters) provides sterile air flow, is equipped with advanced both side electrical interlocked doors, high quality glass window, and UV lamp. Made up of high quality 30...

Standards

ISO 14644-1-Cleanrooms and associated controlled environments-Classification of air cleanliness by particle concentration

ISO 14644-3-Cleanrooms and associated controlled environments-Test methods

Complies with the above standards, but is not limited to them.

Features

1. UV pass box with HEPA filters for clean material transfer between areas.

2. Combines UV disinfection with HEPA filtration for contamination-free transfer.

3. Suitable for cleanrooms, laboratories, pharmaceutical, healthcare and electronics.

4. Includes pass box chamber, UV lamps, HEPA filters, interlocking doors and manual.

5. Supports sterile material transfer with disinfection and particulate filtration.

FAQ

Q1: What testing scenarios is this pass box mainly applied to?

A: The UV pass box with HEPA filters is used in cleanrooms, pharmaceutical manufacturing, biological laboratories, healthcare facilities, electronics manufacturing and research institutions to enable contamination-free transfer of materials, equipment and samples between areas of different cleanliness levels, combining UV disinfection with HEPA filtration for enhanced contamination control. It supports cleanroom material transfer between gowning and production areas, pharmaceutical manufacturing material transfer with disinfection, biological laboratory sample and equipment transfer, healthcare facility sterile supply transfer, electronics manufacturing component transfer, and research laboratory contamination control. The combined UV and HEPA system provides both surface disinfection and particulate filtration, reducing microbial and particulate contamination during material transfer. It is essential for cleanrooms, pharmaceutical, biological, healthcare, electronics and research facilities requiring contamination-free material transfer with UV disinfection and HEPA filtration for cleanroom operations, pharmaceutical manufacturing, biological safety, healthcare sterile supply and electronics production, where the combined UV and HEPA pass box provides both surface disinfection and particulate filtration, reducing microbial and particulate contamination during material transfer between controlled and uncontrolled areas, supporting contamination control, regulatory compliance and product quality in cleanroom and controlled environments.

Q2: What standards does the pass box comply with?

A: The UV pass box with HEPA filters complies with relevant ISO 14644 cleanroom standards, applicable GB/T standards for cleanroom equipment, IEST recommended practices for HEPA filters, and relevant electrical safety standards. Pharmaceutical applications follow cGMP requirements. HEPA filter integrity should be tested per applicable standards (e.g., ISO 14644-3, IEST-RP-CC007). UV safety should follow applicable radiation safety guidelines.

Q3: What is the warranty period for the whole machine and key components?

A: The whole pass box is covered by a 12-month warranty. The chamber, doors, interlock, UV system and housing are covered, while HEPA filters, UV lamps, gaskets and fuses are consumables or accessories. Damage from improper use, filter damage or unauthorized repair is excluded. Extended service contracts are available for cleanroom equipment.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires trained cleanroom or laboratory personnel familiar with contamination control, UV safety and pass box operation. We provide operation manuals, training and application support. Proper material loading, UV cycle setting, door interlock operation, filter maintenance and safety procedures are important for effective contamination control and safe operation.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular maintenance required? What is the recommended calibration cycle?

A: HEPA filter integrity testing (DOP/PAO) every 6-12 months per cleanroom requirements. UV lamp replacement every 9-12 months. Door gasket and interlock inspection regularly. Chamber cleaning and disinfection per schedule. Airflow and pressure verification periodically. Full system performance check annually.

Q7: Are supporting consumables universal?

A: HEPA filters, UV lamps and gaskets are available from specialized suppliers, though system-specific parts should be verified. Long-term consumable cost is moderate depending on filter replacement and lamp life.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes chamber size, material (stainless steel grade), HEPA filter efficiency (H13, H14, U15), UV lamp configuration, door type (mechanical/electronic interlock), airflow design and accessories. Additional filters, lamps and accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Yes, UV pass boxes with HEPA filters include on-site installation, commissioning, HEPA filter integrity testing and operator training by cleanroom equipment specialists. Site preparation guidance is provided before delivery to ensure wall opening, power and environmental requirements are met.

Q10: What types of materials are compatible with this equipment?

A: The UV pass box with HEPA filters transfers materials, equipment, samples and supplies within the chamber size, weight capacity and UV compatibility specification. Materials should be able to withstand UV exposure (some plastics and materials may degrade with prolonged UV). Liquids should be in sealed containers. Highly porous or fibrous materials may not be effectively surface-disinfected by UV. Users should follow proper material loading (not blocking UV or airflow), set appropriate UV exposure time, never open both doors simultaneously (interlock prevents this), never look directly at UV light, replace HEPA filters per schedule, verify filter integrity regularly, and clean the chamber per cleanroom protocols. For pharmaceutical use, the pass box should be qualified (IQ/OQ) and maintained per cGMP requirements, with documentation of UV cycles and filter maintenance. The interlock system should be tested periodically to ensure proper operation and prevent cross-contamination between areas.