Introduction
A vertical autoclave is a laboratory sterilization device that uses pressurized steam at high temperature to sterilize equipment, media, and waste, with the cylindrical chamber oriented vertically and loaded from the top, and it is a common and reliable sterilization instrument in laboratories, hospitals, and industry. In operation, the items to be sterilized are placed in the vertical chamber, the lid is closed and sealed, and steam is generated and admitted into the chamber, raising the temperature and pressure to the sterilization conditions, typically 121 degrees Celsius at about 15 psi, for a specified holding time, typically 15-30 minutes; the high-temperature, high-pressure steam kills microorganisms, including bacteria, spores, viruses, and fungi, and after the cycle, the steam is exhausted and the chamber is cooled before the items are removed. Vertical autoclaves are available in various sizes, from compact benchtop models to large floor-standing units, and they are widely used for sterilizing culture media, glassware, instruments, laboratory waste, and other heat-stable materials, in microbiology, biology, clinical, pharmaceutical, and food laboratories, and in hospitals and clinics, and they are also used in tattoo and piercing studios and other settings that require reliable sterilization. Features include precise pressure and temperature control, safety interlocks, cycle timers, and digital displays, and they must be operated with proper safety precautions and tested regularly to ensure sterilization effectiveness. With their reliability and ease of use, vertical autoclaves are essential for sterilization in laboratories and healthcare facilities.
Vertical Autoclave LVA-T2015
Vertical Autoclave is a semi-automatic sterilizer designed to function within a temperature range of 50°C to 134°C. One-touch sterilization function for quick and easy selection based ...
Vertical Autoclave LVA-T2014
Vertical Autoclave is a semi-automatic sterilizer designed to operate within a temperature range of 50°C to 134°C. It is equipped with advanced an air-cooled chilling device. It includ...
Vertical Autoclave LVA-T2013
Vertical Autoclave offers a generous 50-liter capacity, making it ideal for high-volume sterilization tasks. It uses a microcomputer-controlled graphic display for automatic cycle manage...
Vertical Autoclave LVA-T2012
Vertical Autoclave is made from durable SUS304 stainless steel, ensuring long-lasting performance. It features an up-and-down door mechanism. This compact and reliable autoclave ensures ...
Vertical Autoclave LVA-T2011
Vertical Autoclave operates at a rated pressure of 0.217 MPa to ensure reliable sterilization. Its shell is made of durable, impact-resistant high-temperature thermoplastic. Safety valve...
Vertical Autoclave LVA-T2010
Vertical Autoclave is a semi-automatic sterilizer designed to operate within a temperature range of 50°C to 134°C. It supports both external and internal discharging for exhaust. It fe...
Vertical Autoclave LVA-T2013
Vertical Autoclave is a class N-type top-loading vertical pressure steam sterilizer, with hand wheel type, quick to open door structure. It offers a chamber capacity of 100 stainless ste...
Vertical Autoclave LVA-T2012
Vertical Autoclave is a class N-type top-loading vertical pressure steam sterilizer, with hand wheel type, quick to open door structure. It offers a chamber capacity of 75 stainless stee...
Vertical Autoclave LVA-T2011
Vertical Autoclave is a class N-type top-loading vertical pressure steam sterilizer, with hand wheel type, quick to open door structure. It offers a chamber capacity of 50 stainless stee...
Vertical Autoclave LVA-T2010
Vertical Autoclave is a class N-type top-loading vertical pressure steam sterilizer, with hand wheel type, quick to open door structure. It offers a chamber capacity of 35 stainless stee...
Vertical Autoclave LVA-T2015
Vertical Autoclave operates at a working pressure of 0.22 MPa and a consistent temperature of 134°C. Its sterilization time can be set from 0 to 99 hours and 59 minutes, ensuring reliab...
Vertical Autoclave LVA-T2014
Vertical Autoclave offers a chamber volume of 120 liters, designed to meet the demanding needs of laboratory facilities. It operates at a working pressure of 0.22 Mpa, ensuring effective...
Vertical Autoclave LVA-T2013
Vertical Autoclave operates at a working pressure of 0.22 Mpa, ensuring effective sterilization. This autoclave supports sterilization times from 0 to 99 hours 59 minutes, allowing flexi...
Vertical Autoclave LVA-T2012
Vertical Autoclave features a spacious 75L chamber for reliable sterilization of laboratory equipment. It supports a temperature range of 105 to 134°C with exceptional temperature accur...
Vertical Autoclave LVA-T2011
Vertical Autoclave features a 50L chamber, engineered for efficient sterilization across laboratories. With a sterilization time setting from 0 to 99 hours 59 minutes and heat uniformity...
Vertical Autoclave LVA-T2010
Vertical Autoclave operates at a working pressure of 0.22 MPa and a maximum temperature of 134°C, ensuring thorough sterilization. It offers temperature accuracy of ±0.1°C and heat un...
Vertical Autoclave LVA-T2015
Vertical Autoclave features working pressure of 0.22 MPa and a working temperature of 134°C, ensuring efficient sterilization. It offers customizable sterilization time from 0 to 60 min...
Vertical Autoclave LVA-T2014
Vertical Autoclave features a spacious 120L chamber capacity, designed to meet the high-volume sterilization needs of laboratories. Its sterilization cycle can be adjusted, and a heat av...
Vertical Autoclave LVA-T2013
Vertical Autoclave features temperature range of 105 to 134°C, offering flexibility in sterilization cycles. With a 100-liter chamber capacity, it operates at a working pressure of 0.22...
Vertical Autoclave LVA-T2012
Vertical Autoclave features a spacious 75-liter chamber, ideal for high-volume sterilization needs in laboratories. It offers a flexible sterilization time from 0 to 60 minutes and heat ...
Vertical Autoclave LVA-T2011
Vertical Autoclave operates at a working pressure of 0.22 MPa, with an adjustable temperature range from 105°C to 134°C. Its heat uniformity is maintained within ±1°C, ensuring thoro...
Vertical Autoclave LVA-T2010
Vertical Autoclave offers flexible sterilization time settings from 0 to 60 minutes and ensures uniform heat distribution. With a spacious 35L chamber, it operates at a working pressure ...
Vertical Autoclave LVA-Q13
Vertical Autoclave features working pressure of 0.22 Mpa, suitable for sterilizing a wide variety of instruments and materials. With a temperature display accuracy of 0.1℃, it guarantee...
Vertical Autoclave LVA-Q12
Vertical Autoclave offers a 75-liter capacity for efficient operation in laboratories and medical environments. It operates at a working pressure of 0.22 Mpa, delivering powerful sterili...
Vertical Autoclave LVA-Q11
Vertical Autoclave supports a wide temperature range from 100 to 134°C, suitable for sterilizing various instruments. With a 50-liter chamber capacity and constructed entirely from high...
Vertical Autoclave LVA-Q10
Vertical Autoclave features a robust design with a chamber capacity of 35 liters. It supports a sterilization temperature range from 100°C to 134°C for varied application needs. It is ...
Vertical Laboratory Autoclave LVA-T814
Vertical features a 40-liter stainless steel chamber for efficient and precise operation in laboratory settings. It operates at a working pressure of 0.22 MPa and a working temperature o...
Vertical Autoclave LVA-T515
Vertical Autoclave offers flexible sterilization and drying cycles, each adjustable from 0 to 99 minutes or up to 99 hours and 59 minutes. It features precise temperature accuracy of ±0...
Vertical Autoclave LVA-T514
Vertical Autoclave features a spacious 150-liter chamber, ideal for bulk sterilization tasks. This unit operates within a working pressure range of 0 to 0.22 MPa and a temperature range ...
Vertical Autoclave LVA-P15
Vertical Autoclave offers chamber capacity of 150L to meet the stringent sterilization needs of laboratories. Operating at a working pressure of 0.22 MPa and a temperature of 134°C, it ...
Vertical Autoclave LVA-P14
Vertical Autoclave features a robust 120L chamber capacity, designed for high-volume sterilization. It operates at a working pressure of 0.22 MPa and reaches sterilization temperatures u...
Vertical Autoclave LVA-P13
Vertical Autoclave offers a spacious 100-liter chamber capacity, to deliver high-efficiency sterilization. It operates at a working pressure of 0.22 MPa and maintains a consistent workin...
Vertical Autoclave LVA-P12
Vertical Autoclave offers 75L chamber capacity for reliable sterilization in laboratories, clinics, and research facilities. It offers flexible sterilization and drying times, with ±0.1...
Vertical Autoclave LVA-P11
Vertical Autoclave features chamber capacity of 50L for high-performance steam sterilization across laboratory and research settings. It offers a temperature range of 100 to 134°C, maki...
Vertical Autoclave LVA-P10
Vertical Autoclave offers a chamber capacity of 35 liters, supporting medium-scale sterilization needs. Operating at a working pressure of 0.22 Mpa, it provides a wide sterilization rang...
Vertical Autoclave LVA-N13
Vertical Autoclave is constructed from durable SUS304 stainless steel for long-lasting performance and corrosion resistance. It features an control system for precise sterilization manag...
Vertical Autoclave LVA-N12
Vertical Autoclave is a semi-automatic vertical sterilizer that operates within a temperature range of 50°C to 134°C. It features three baskets to ensure efficient load distribution du...
Vertical Autoclave LVA-N11
Vertical Autoclave is a semi-automatic unit with a 100-liter capacity. It features a durable, corrosion-resistant stainless-steel chamber designed for long-term reliability and low maint...
Vertical Autoclave LVA-O25
Vertical Autoclave uses SUS304 stainless steel for the inner chamber, ensuring durability and corrosion resistance. It features a shift-type quick-open door with a mechanical safety inte...
Vertical Autoclave LVA-O24
Vertical Autoclave performs reliably in environments with ambient temperatures ranging from 5°C to 45°C. An automatic shutdown is initiated at the end of the sterilization phase, accom...
Vertical Autoclave LVA-O23
Vertical Autoclave operates within a temperature range of 50°C to 126°C. It features a console with an with graphic display and automatic cycle control. Our autoclave is ideal for use ...
Vertical Autoclave LVA-O22
Vertical Autoclave is a high-performance sterilizer featuring a 50-liter chamber capacity. It offers reliable semi-automatic operation for efficient and convenient sterilization. These u...
Vertical Autoclave LVA-O21
Vertical Autoclave operates at a rated pressure of 0.142 MPa. Its shell is made from high-temperature thermoplastic with excellent impact resistance and stainless-steel components. The p...
Vertical Autoclave LVA-O20
Vertical Autoclave is a reliable sterilizer featuring a robust design with dimensions of 670 × 680 × 1230 mm. It is available in a semi-automatic configuration, offering operational fl...
Vertical Autoclave LVA-M13
Vertical Autoclave has a capacity of 100 solenoid valves. The control system is microcontroller-based, operated through a 5-inch color capacitive touch screen. Its additional features in...
Vertical Autoclave LVA-M12
Vertical Autoclave has a capacity of 80 chamber. This autoclave features a hand wheel-style quick-opening door for convenient and secure operation. The pipeline system uses flexible hose...
Vertical Autoclave LVA-M11
Vertical Autoclave has a capacity of 60 color capacitive touch screen. The main tank body is made of 304 stainless-steel, enhancing its durability. It features eight sterilization progr...
Vertical Autoclave LVA-T2025
Vertical Autoclave operates between 50°C and 134°C. It features a digital control panel for precise temperature, pressure, and time regulation. Its durable stainless-steel construction...
Vertical Autoclave LVA-T2024
Vertical Autoclave is an 80-liter vertical steam sterilizer designed for efficient sterilization. It features a lid interlock system to prevent opening under pressure for added safety. T...
Vertical Autoclave LVA-T2023
Vertical Autoclave operates between 50°C and 134°C to meet diverse sterilization needs. Its console with dynamic graphics simplifies function selection. This system uses a microcompute...
Standards
IEC 61010-2-040:2020-Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
ISO 17665-1:2006-Sterilization of health-care products-Moist heat-Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
Complies with the above standards, but is not limited to them.
Features
1. Vertical autoclave for top-loading steam sterilization of laboratory and medical items.
2. Vertical chamber design with large capacity for efficient, high-volume sterilization.
3. Suitable for hospitals, laboratories, pharmaceutical, food and research institutions.
4. Includes pressure chamber, lid with safety valve, heater, controller and operation manual.
5. Provides reliable steam sterilization for instruments, glassware, media and waste.
FAQ
Q1: What testing scenarios is this autoclave mainly applied to?
A: The vertical autoclave is used in hospitals, clinical laboratories, research institutions, pharmaceutical manufacturing, food processing, educational facilities and microbiology laboratories to perform steam sterilization of instruments, glassware, culture media, waste and other heat-stable items in a top-loading vertical chamber with large capacity. It supports hospital and clinical instrument sterilization, laboratory glassware and media sterilization, microbiological waste decontamination, pharmaceutical equipment sterilization, food processing equipment sterilization, and educational laboratory use. The vertical top-loading design provides large capacity with a compact footprint, making it suitable for high-volume sterilization in space-limited facilities. It is essential for hospitals, laboratories, pharmaceutical, food and research institutions requiring large-capacity vertical steam sterilization for instrument sterilization, media preparation, glassware decontamination, waste treatment and general laboratory use, where the vertical top-loading design provides large capacity with a compact footprint, supporting efficient, high-volume sterilization in clinical, research, pharmaceutical and educational environments requiring reliable, effective steam sterilization for a wide range of heat-stable items.
Q2: What standards does the autoclave comply with?
A: The vertical autoclave complies with relevant ISO, EN and GB/T standards for steam sterilizers, applicable pressure vessel regulations, and IEC 61010 laboratory safety standards. Clinical and medical use may follow applicable medical device regulations. Sterilization efficacy should be verified with biological indicators per applicable standards. Safety valves and pressure gauges should be inspected per pressure vessel regulations.
Q3: What is the warranty period for the whole machine and key components?
A: The whole vertical autoclave is covered by a 12-month warranty. The chamber, lid, heater, controller and safety valves are covered, while gaskets, filters and fuses are consumables or accessories. Damage from improper use, dry operation, overpressure or unauthorized repair is excluded. Extended warranty may be available.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation requires trained personnel familiar with autoclave operation, steam sterilization and pressure vessel safety. We provide an operation manual and remote guidance. Proper water filling, loading, cycle selection, pressure monitoring and safety procedures are important for effective sterilization and safe operation, particularly for large vertical chambers.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular maintenance required? What is the recommended calibration cycle?
A: Gasket inspection and replacement per usage or when leakage occurs. Safety valve testing periodically per pressure vessel regulations. Pressure gauge calibration per schedule. Routine descaling according to water quality. Biological indicator testing periodically for sterilization efficacy verification. Chamber cleaning after each use. Full maintenance per manufacturer schedule.
Q7: Are supporting consumables universal?
A: Gaskets, filters, sterilization indicators and biological indicators are available from multiple suppliers, though compatibility should be verified. Long-term consumable cost is low.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes chamber capacity, pressure rating, control type (manual, semi-automatic, fully automatic), timer, basket configuration and accessories. Additional baskets, trays and accessories can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: Standard delivery includes the vertical autoclave and instruction manual. On-site installation and training are recommended for large capacity units and can be arranged at additional cost. Remote guidance is provided.
Q10: What types of items are compatible with this equipment?
A: The vertical autoclave sterilizes heat- and moisture-stable items including glassware, metal instruments, culture media, laboratory waste and certain plastics within the chamber capacity and pressure rating. Heat-sensitive, volatile or flammable items must not be autoclaved. Liquids should be in vented containers with proper volume limits. The top-loading design accommodates tall items. Users should follow proper loading practices to ensure steam penetration, use distilled or deionized water, never operate without water, ensure the safety valve is functional, use biological indicators to verify sterilization efficacy periodically, allow proper cooling before opening, and follow pressure vessel safety regulations. The chamber should not be overloaded, and items should be packaged or wrapped appropriately for steam penetration. For waste decontamination, follow proper biohazard handling procedures and ensure complete sterilization before disposal.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.