Introduction
Vertical Autoclave operates at a working pressure of 0.22 Mpa, ensuring effective sterilization. This autoclave supports sterilization times from 0 to 99 hours 59 minutes, allowing flexible operation. It comes with a built-in steam generator and a fully stainless-steel chamber for enhanced durability. In addition, it features a microprocessor-based control system and a clear digital display. It is well-suited for laboratory settings where high-capacity sterilization is essential.
It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.Applications
Our Vertical Autoclave is widely used in research laboratories, pharmaceutical industries, and educational institutions for the sterilization of laboratory glassware, culture media, rubber materials, and other heat-resistant items.
Specifications
| Capacity | 100 L |
| Working Pressure | 0.22 MPa |
| Working Temperature | 134°C |
| Temperature Range | 105 to 134°C |
| Sterilization Time | 0 to 99 hours 59 minutes |
| Temperature Accuracy | ±0.1°C |
| Heat Uniformity | ≤1°C |
| Control System | Microprocessor-based |
| Display | Digital Display |
| Steam Generator | Built-in, Stainless Steel 304 |
| Chamber Material | Fully Stainless Steel 304 |
| Power Supply | 110 to 220V, 50/60Hz |
| Power Consumption | 4.5 kW |
| Chamber Volume | 100L / Ø440 × 650 mm |
| Product Dimensions | 540 × 560 × 1250 mm |
| Package Dimensions | 680 × 680 × 1370 mm |
| Net Weight | 85 kg |
| Gross Weight | 110 kg |
Features
High Capacity
Efficient Sterilization
Precise Control
Wide Temperature Range
Superior Accuracy
User-Friendly Interface
Robust Construction
Flexible Sterilization Time
Compact Design
Power Efficient
FAQs
1. What are the key specifications that make the Vertical Autoclave suitable for high-volume sterilization tasks?
The Vertical Autoclave is designed for large-scale sterilization with a spacious 100L chamber (Ø440 × 650 mm), making it ideal for processing bulk instruments in hospitals, research labs, and pharmaceutical facilities. It operates at a working pressure of 0.22 MPa and a sterilization temperature of 134°C, with a temperature range from 105°C to 134°C. Its precise control system offers ±0.1°C accuracy and heat uniformity within less than equal to 1°C, ensuring reliable and consistent sterilization results. These features make it highly efficient for intensive sterilization requirements.
2. How does the microprocessor-based control system in the Vertical Autoclave enhance user experience and sterilization reliability?
The Vertical Autoclave features an advanced microprocessor-based control system that allows precise regulation of temperature, pressure, and sterilization time. This technology enhances user convenience by automating critical parameters, minimizing human error, and ensuring consistent sterilization cycles. The digital display provides real-time updates, making it easy for operators to monitor operations. Such accuracy is especially important in medical and lab environments where even slight deviations can affect sterility.
3. What safety and durability features are integrated into the Vertical Autoclave ?
Safety and longevity are core design principles of the Vertical Autoclave . The unit is constructed entirely with high-grade stainless steel 304, both in the chamber and the built-in steam generator, ensuring corrosion resistance and long-term performance. The autoclave is equipped with multiple safety mechanisms (such as pressure and temperature monitoring) that prevent overloading or overheating. With a power consumption of 4.5 kW and a voltage range of 110 to 220V, it operates efficiently while maintaining robust safety standards.
4. Can the Vertical Autoclave be used for different types of materials and instruments?
Yes, the Vertical Autoclave is designed to sterilize a wide range of materials, including surgical instruments, laboratory glassware, culture media, and rubber components. Its flexible temperature range and programmable sterilization time (up to 99 hours 59 minutes) allow for customized cycles depending on the type and load of materials. This versatility makes it highly valuable for various applications in hospitals, microbiology labs, educational institutions, and pharmaceutical manufacturing.
5. What makes the Vertical Autoclave a good choice for space-constrained laboratories or medical facilities?
Despite its large 100L capacity, the Vertical Autoclave has a compact footprint with dimensions of 540 × 560 × 1250 mm. Its space-efficient vertical design allows it to fit into tight corners of labs or hospital sterilization rooms without compromising on performance. Additionally, with a net weight of 85 kg and a gross weight of 110 kg, the autoclave is reasonably manageable for transport and installation in various workspaces.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.