Introduction

A lighting incubator is a laboratory instrument that provides controlled temperature and light conditions for the cultivation of plants, algae, and light-dependent organisms, and for light-sensitive experiments, and it is used in plant science, agriculture, microbiology, and environmental research. The incubator combines precise temperature control with programmable illumination, using fluorescent, LED, or other light sources that provide a controlled light intensity, spectrum, and photoperiod, which can be programmed to simulate day and night cycles; the temperature and light are controlled independently, and the interior is fitted with shelves for culture vessels, trays, and Petri dishes, and the conditions can be programmed with multiple steps to simulate natural or specific environmental cycles. Lighting incubators are used in plant science for seed germination, seedling growth, plant tissue culture, and studies of plant development and physiology; in agriculture for growth studies and propagation; in microbiology for cultivation of photosynthetic microorganisms, such as algae and cyanobacteria; in environmental science for studies of the effect of light and temperature on organisms; and in food science for ripening and storage studies, and they are used in universities, research institutes, and agricultural laboratories. They are available in various sizes, from compact models to large walk-in growth chambers, with features such as programmable light and temperature profiles, alarms, and data logging. With their controlled environment, lighting incubators are essential for cultivation and experiments requiring both light and temperature control.

Lighting Incubator LLI-T2010

Lighting Incubator LLI-T2010



Lighting Incubator is a light illuminating incubator with light source having illumination range of 0 to 20,000 lx. It has chamber capacity of 200 L and has ambient temperature of 0 to 4...
Lighting Incubator LLI-T2011

Lighting Incubator LLI-T2011



is a 2 side light illuminating incubator runs under microprocessor control system with lighting illumination of 0 to 15000 lx. Offers two types of temperature control range: with illumin...
Lighting Incubator LLI-T2012

Lighting Incubator LLI-T2012



is a 2 side light illuminating incubator runs under microprocessor control system with lighting illumination of 0 to 20000 lx. Offers two types of temperature control range: with illumin...
Lighting Incubator LLI-T2010

Lighting Incubator LLI-T2010



is a 2 side light illuminating incubator runs under microprocessor control system with lighting illumination of 0 to 12000 lx. Offers two types of temperature control range: with illumin...

Standards

ISO 11133:2014-Microbiology of food, animal feed and water-Preparation, production, storage and performance testing of culture media

Complies with the above standards, but is not limited to them.

Features

1. Lighting incubator for controlled temperature and illumination for plant and insect culture.

2. Programmable light cycles with adjustable intensity for photoperiod experiments.

3. Suitable for plant science, entomology, agriculture, biology and research laboratories.

4. Precise temperature control with uniform lighting for reproducible growth conditions.

5. Includes temperature control, lighting system, shelves, timer and operation manual.

FAQ

Q1: What testing scenarios is this incubator mainly applied to?

A: The lighting incubator is used in plant science, agricultural research, entomology, biology, environmental science, pharmaceutical research and educational institutions to provide controlled temperature and illumination conditions for growing plants, rearing insects, culturing photosynthetic organisms and conducting photoperiod experiments. It supports plant seed germination and seedling growth, insect rearing and life cycle studies, algae and photosynthetic microorganism culture, plant physiology experiments (photoperiod, light intensity effects), agricultural crop research, and educational biology demonstrations. The programmable light cycles enable simulation of day-night patterns and controlled photoperiod experiments. It is essential for plant science, agricultural, entomology and biology laboratories requiring controlled temperature and illumination for plant growth, insect rearing, photosynthetic organism culture, photoperiod experiments and research, where precise control of temperature, light intensity and photoperiod is critical for plant development, insect life cycles, photosynthesis studies, agricultural research and biological experiments requiring standardized environmental conditions in laboratory and research settings.

Q2: What standards does the incubator comply with?

A: The lighting incubator complies with relevant IEC 61010 laboratory electrical safety standards and applicable GB/T standards for plant growth and insect rearing equipment. Research applications follow good laboratory practice and applicable institutional guidelines. Temperature and light intensity should be calibrated periodically for experimental reproducibility.

Q3: What is the warranty period for the whole machine and key components?

A: The whole incubator is covered by a 12-month warranty. The temperature control, lighting system, fan and controller are covered, while bulbs, shelves and gaskets are consumables or accessories. Damage from improper use, water spillage or unauthorized repair is excluded.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires basic training in environmental control, plant/insect culture and programmable settings. We provide an operation manual and remote guidance. Proper temperature and light cycle programming, sample handling, watering and maintenance are important for successful culture and experiments.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Temperature calibration against a reference thermometer recommended every 6-12 months. Light intensity measurement and bulb replacement per usage or when dim. Photoperiod timer verification periodically. Fan and ventilation inspected regularly. Routine cleaning recommended, particularly for plant and insect culture.

Q7: Are supporting consumables universal?

A: Light bulbs, shelves, gaskets and growing supplies are available from multiple suppliers, though bulb type and spectrum should match the specification. Long-term consumable cost is low to moderate depending on usage.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes chamber capacity, temperature range, light type (fluorescent, LED), light spectrum, intensity control, photoperiod programming and shelving. Additional accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Standard delivery includes the incubator and accessories with an operation manual. On-site installation, calibration and training are not included for standard orders but can be arranged for research setup. Remote guidance is provided.

Q10: What types of organisms are compatible with this equipment?

A: The lighting incubator supports growth of plants, insects, algae and photosynthetic microorganisms within the temperature, light and humidity specification. Different species require specific temperature ranges, light spectra, intensities and photoperiods. Users should select appropriate light spectrum and intensity for the organism, program correct photoperiod and temperature cycles, ensure proper watering and humidity for plants, maintain cleanliness to prevent mold and pest contamination, calibrate temperature and light intensity regularly, and follow proper culture techniques for the specific organism. For insect rearing, proper containment and biosecurity measures should be followed to prevent escape. The incubator should be cleaned regularly between experiments to prevent cross-contamination.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry