Introduction

A UV spectrometer measures ultraviolet absorption of samples. It is widely used in chemical and biological analysis. The system ensures optical precision. It solves subjective measurement errors. By providing spectral detection, it supports research accuracy.

UV Spectrometer LUVSP-T2011

UV Spectrometer LUVSP-T2011



UV Spectrometer offers a lightweight design that covers the ultraviolet region with a wavelength range of 200 to 535 nm. It features a stable grating and supports a customizable slit, en...
UV Spectrometer LUVSP-T2010

UV Spectrometer LUVSP-T2010



UV Spectrometer offers a compact design with a spectral range of 200 to 425 nm. It has a high-resolution linear detector and supports fast data acquisition via 2.0 connectivity. The ligh...

Standards

European Pharmacopoeia 2.2.25-Spectrophotometry, ultraviolet and visible

ASTM E275-08(2022)-Standard Practice for Describing and Measuring Performance of Ultraviolet, Visible, and Near-Infrared Spectrophotometers

Complies with the above standards, but is not limited to them.

Features

1. Cuvette holders and accessories suit different sample types.

2. Low stray-light design supports accurate absorbance readings.

3. USB, RS232 or printer options export results and reports.

4. Diffraction grating or monochromator provides precise wavelength selection.

5. Software tools support spectral scans, standard curves and kinetics.

FAQ

What are the main applications of the UV Spectrometer?

The UV Spectrometer is used to measure absorbance, transmittance or concentration of samples across a defined wavelength range. It supports quantitative analysis, purity checks, kinetics and quality control in chemistry, biology, pharmaceutical and environmental laboratories.

Which standards and regulations apply to the UV Spectrometer?

The instrument is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for spectrophotometers, including wavelength and photometric accuracy. Procedures should follow applicable standard methods. Compliance documentation can be provided on request.

What does the warranty cover?

We provide a 12-month limited warranty on the instrument and its key working parts. Consumables, accessories and parts subject to normal wear are excluded, as is damage caused by incorrect operation or maintenance. An extended service plan is available on request.

Is the UV Spectrometer difficult to operate?

Routine operation is straightforward and is covered in the user manual, including setup, daily use and basic maintenance. Staff with basic laboratory experience can run it after a short familiarisation. We provide remote guidance and can arrange on-site training where required.

How long does delivery usually take?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Is calibration included?

To protect result reliability, periodic verification should be performed, typically once or twice a year. The instrument arrives factory-calibrated, and self-check routines help spot drift. We offer traceable calibration service if the site needs it.

Where do we get replacement parts?

No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.

Can the UV Spectrometer be customised?

Customisation is supported for many installations, including tailored parameters, connections and accessories. Our team reviews the requirement and confirms feasibility and lead time in advance. We avoid committing to options that cannot be delivered reliably.

Do you provide on-site installation?

Most models can be commissioned by following the manual, including positioning, connections, checks and a first test run. Remote guidance is available during start-up. On-site installation, commissioning and training can be arranged separately where required.

What maintenance and safety points matter?

Do not measure highly corrosive or incompatible samples, use dirty cuvettes or skip blank correction. Verify wavelength and photometric accuracy periodically. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry