Introduction

Galvanostat enables current-controlled electrochemical testing essential for battery evaluation, corrosion studies, and deposition processes. These offer programmable current profiles, data logging features, and modular channels for multielectrode systems. They include high-speed response, stable current output, and integrated control software to support diverse protocols. These support methods such as chronoamperometry, chronopotentiometry, and cyclic voltammetry in advanced research. Galvanostat supports electrochemical experimentation across energy storage, surface coating, and material interface analysis.

Galvanostat T-GAT-S2100

Galvanostat T-GAT-S2100

Galvanostat offers potential control range of ±10V and current control range of ±2.0A. Equipped with high control accuracy of 0.1% full scale reading for both potential and current. Inco...

Standards

IEC 60746-1:2003-Expression of performance of electrochemical analyzers-Part 1: General

Complies with the above standards, but is not limited to them.

Features

1. Automatic temperature compensation reduces measurement error.

2. Water-resistant, portable design suits field and bench use.

3. Multiple measurement modes cover a range of applications.

4. Data hold, logging and export support records and reports.

5. Multi-parameter capability consolidates several bench measurements.

FAQ

What are the main applications of the Galvanostat?

The Galvanostat is used to measure electrochemical properties such as pH, conductivity, dissolved oxygen or ion concentration. It supports water treatment, environmental monitoring, chemical, pharmaceutical, food and research laboratories.

Which standards and regulations apply to the Galvanostat?

The meter is designed with reference to IEC 61010 electrical safety and relevant GB/T standards for electrochemical measurement, with procedures following applicable standard methods and buffer systems. Compliance documentation can be provided on request.

What warranty comes with the Galvanostat?

The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.

How easy is the Galvanostat to use?

The controls are designed for regular laboratory use, so most users become confident after a brief introduction. The manual walks through each step, and common settings can be saved for repeat work. Online or on-site training is available if the site requires it.

How long does delivery usually take?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Is calibration included?

Regular calibration keeps measurements within the stated accuracy; an annual check is typical, with shorter intervals for heavy or regulated use. Reference standards and procedures are described in the manual. We can quote calibration with certificates.

Where do we get replacement parts?

Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.

Can the Galvanostat be customised?

Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.

Is installation and commissioning included?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What should be avoided when using the Galvanostat?

Do not let the electrode dry out, measure outside the rated range or store probes incorrectly. Rinse and condition electrodes and calibrate regularly. Follow the operating instructions.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.