Introduction

Single Stage Rotary Vane Vacuum Pump delivers reliable vacuum generation with efficient and steady operation. They operate with oil-sealed mechanisms that maintain stable airflow and consistent performance. These pumps feature compact bodies, low noise levels, and effective heat dissipation systems. Their streamlined structure and minimal maintenance requirements ensure long-term usability. Vacuum Pump offers durable construction, smooth functioning, and supports standard vacuum processes.

Single Stage Rotary Vane Vacuum Pump T-SVP-S2107

Single Stage Rotary Vane Vacuum Pump T-SVP-S2107

Single Stage Rotary Vane Vacuum Pump 20 m³/h pumping speed for reliable performance. Built with rotary vane mechanism to support seamless evacuation across demanding setups. Works at ste...
Single Stage Rotary Vane Vacuum Pump T-SVP-S2106

Single Stage Rotary Vane Vacuum Pump T-SVP-S2106

Single Stage Rotary Vane Vacuum Pump delivers 10CFM displacement for maintaining optimal vacuum. Constructed with reinforced mechanics to sustain prolonged functional cycles without perfor...
Single Stage Rotary Vane Vacuum Pump T-SVP-S2105

Single Stage Rotary Vane Vacuum Pump T-SVP-S2105

Single Stage Rotary Vane Vacuum Pump delivers 8.0 CFM free air displacement. Built with durable internal components that support long-term continuous vacuum generation. Incorporates high-c...
Single Stage Rotary Vane Vacuum Pump T-SVP-S2104

Single Stage Rotary Vane Vacuum Pump T-SVP-S2104

Single Stage Rotary Vane Vacuum Pump delivers 6.0 CFM displacement, ensuring steady airflow output. Equipped with 1/2HP motor enabling smooth and balanced performance. Built to run at cons...
Single Stage Rotary Vane Vacuum Pump T-SVP-S2103

Single Stage Rotary Vane Vacuum Pump T-SVP-S2103

Single Stage Rotary Vane Vacuum Pump delivers higher displacement rate of 4.5CFM. Designed with single-stage configuration, it enables air compression in one step, simplifying functionalit...
Single Stage Rotary Vane Vacuum Pump T-SVP-S2102

Single Stage Rotary Vane Vacuum Pump T-SVP-S2102

Single Stage Rotary Vane Vacuum Pump features 3.5 CFM free air displacement and 1/3HP motor. Rotates at steady speed of 1440 RPM for stable flow output. Built with tightly sealed chamber t...
Single Stage Rotary Vane Vacuum Pump T-SVP-S2100

Single Stage Rotary Vane Vacuum Pump T-SVP-S2100

Single Stage Rotary Vane Vacuum Pump offers air displacement rate of 1.8CFM. Delivers deep vacuum down to 5 Pa, ensuring consistent extraction in sealed systems. Built with high-speed moto...
Single Stage Rotary Vane Vacuum Pump T-SVP-S2101

Single Stage Rotary Vane Vacuum Pump T-SVP-S2101

Single Stage Rotary Vane Vacuum Pump delivers 2.5 CFM air displacement with 1440 RPM rotation. Achieves 5 Pa vacuum pressure, ensuring consistent and stable performance. Built with oil-sea...

Standards

ISO 21360-1:2020-Vacuum technology-Standard methods for measuring vacuum-pump performance-Part 1: General description

GB/T 40344.1-2021-Vacuum technology-Standard methods for measuring vacuum-pump performance-Part 1: General description

Complies with the above standards, but is not limited to them.

Features

1. Diaphragm, peristaltic and rotary models suit different media.

2. Quiet motor and vibration damping improve comfort.

3. Gauge and regulator allow clear control of output.

4. Stable flow or vacuum supports repeatable processes.

5. Quick-release fittings speed tubing changes.

FAQ

What are the main applications of the Single Stage Rotary Vane Vacuum Pump?

The Single Stage Rotary Vane Vacuum Pump is used to move, evacuate or transfer fluids and gases in laboratory and process work. It supports filtration, vacuum drying, aspiration, chromatography and sample handling.

What standards does the Single Stage Rotary Vane Vacuum Pump comply with?

The pump is designed with reference to IEC 61010 electrical safety and relevant GB/T standards for laboratory pumps. Vacuum and pressure ratings should match the application. Compliance documentation can be provided on request.

What warranty comes with the Single Stage Rotary Vane Vacuum Pump?

The complete unit carries a 12-month warranty from delivery, covering the main body, core components and controller against manufacturing defects. Consumables and wearing parts such as filters, seals and probes are not covered. Damage from misuse, improper power or unauthorised repair is excluded, and extended warranty can be quoted.

Will staff need special training?

Routine operation is straightforward and is covered in the user manual, including setup, daily use and basic maintenance. Staff with basic laboratory experience can run it after a short familiarisation. We provide remote guidance and can arrange on-site training where required.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Is calibration included?

Factory calibration is included, and routine verification is recommended every 6 to 12 months using suitable reference materials. Regulated sites may require more frequent checks and documented records. Calibration support and certificates can be provided on request.

Where do we get replacement parts?

Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.

Can the Single Stage Rotary Vane Vacuum Pump be customised?

A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.

Is installation and commissioning included?

The unit is delivered ready for set-up, with clear commissioning steps in the manual. We provide remote technical support during installation. For larger or regulated systems, a factory-trained engineer can attend on site on request.

What should be avoided when using the Single Stage Rotary Vane Vacuum Pump?

Do not pump incompatible, corrosive or particulate media without protection, run dry or block exhaust. Use traps and inlet filtration. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.