Introduction

Ozone meter delivers precise ozone measurements for air quality and safety. They employ UV absorption, electrochemical sensors, or fluorescence methods for accurate gas detection. They offer real-time readings for continuous monitoring and safety compliance. They are provided with long battery life and external power options. ozone meter applied in industrial emissions, environmental research, occupational health, meteorology, agriculture and air quality.

Ozone Meter T-OZM-S2100

Ozone Meter T-OZM-S2100

Ozone Meter uses the Beer-Lambert Law for monitoring low concentrations of ozone using UV absorption. With a flow rate of 1.5L/min, they operate continuously, providing real-time data. It ...

Standards

ISO 13964:1998-Air quality-Determination of ozone in ambient air-Ultraviolet photometric method

ISO 10313:1993-Ambient air-Determination of the mass concentration of ozone-Chemiluminescence method

ISO 6143:2001-Gas analysis-Comparison methods for determining and checking the composition of calibration gas mixtures

Complies with the above standards, but is not limited to them.

Features

1. Ships with a start-up kit and traceable factory test record.

2. Calibration and self-check functions support accuracy.

3. Easy cleaning and maintenance extend service life.

4. Rugged, field-tested construction holds up under daily laboratory use.

5. Data output or recording supports traceable records.

FAQ

What are the main applications of the Ozone Meter?

The Ozone Meter is used for a defined laboratory measurement, preparation or processing task. It supports analytical, quality-control, research, clinical or industrial work where consistent, repeatable results are required.

Which standards and regulations apply to the Ozone Meter?

The instrument is designed with reference to IEC 61010 electrical safety, the applicable international standard for the measurement or process and relevant GB/T standards. Procedures should follow the relevant method. Compliance documentation can be provided on request.

How long is the warranty period?

The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.

Is the Ozone Meter difficult to operate?

The controls are designed for regular laboratory use, so most users become confident after a brief introduction. The manual walks through each step, and common settings can be saved for repeat work. Online or on-site training is available if the site requires it.

What is the typical lead time for order delivery?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

How often should the Ozone Meter be calibrated?

Factory calibration is included, and routine verification is recommended every 6 to 12 months using suitable reference materials. Regulated sites may require more frequent checks and documented records. Calibration support and certificates can be provided on request.

Are the consumables universal or proprietary?

Common consumables and standard spare parts are available through our service channel and are not locked to proprietary formats. Quote the model and serial number when ordering so the correct items are supplied. Lead time for standard parts is usually short.

Are options or configurations available?

A range of options is available to match the application, such as alternative settings, fittings, data outputs or power supply. We confirm each option and its effect on price and schedule up front. Larger custom builds can be discussed.

Do you provide on-site installation?

Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.

What should be avoided when using the Ozone Meter?

Do not use the instrument outside its rated range or intended samples, skip calibration or ignore safety and maintenance instructions. Follow the operating manual and laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry