Introduction
A non refrigerated incubator is a laboratory incubator without the refrigeration, used for the cultivation and the incubation of the microorganisms, the cells, and the biological samples at the temperatures above the ambient, and it is used in the microbiology, the biology, the clinical, the food, and the many other laboratories. The non refrigerated incubator consists of an insulated chamber, a heating system, a temperature control system, a fan or the convection for the air circulation, and the shelves, and it provides the controlled temperature in the chamber, which is above the ambient temperature, with features such as the digital temperature control, the timer, and the over-temperature protection; the non refrigerated incubator is used for the cultivation of the bacteria, the yeast, the molds, and the cells, for the incubation of the samples, for the BOD (biochemical oxygen demand) tests, for the storage of the cultures, for the microbial tests, and for many other applications, and it is available in various sizes, from the bench-top models to the large floor-standing models; the non refrigerated incubator provides a stable and a uniform temperature for the incubation, and it is an essential instrument in the laboratory. Non refrigerated incubators are used in the microbiology laboratories, in the biology laboratories, in the clinical laboratories, in the food industry, and for many other applications. With their heating, non refrigerated incubators are essential for the incubation.
Non-refrigerated Incubator T-S292NRI
Non-refrigerated Incubator is designed with a high precision microprocessor controller which maintains specific temperature control within the range of ambient +5 °C to 65 °C with an ...
Non-refrigerated Incubator T-S293NRI
Non-refrigerated Incubator is designed with a high precision microprocessor controller which maintains specific temperature control within the range of ambient +5 °C to 65 °C with an ...
Non-refrigerated Incubator T-S294NRI
Non-refrigerated Incubator is designed with a high precision microprocessor controller which maintains specific temperature control within the range of ambient +5 °C to 65 °C with an ...
Non-refrigerated Incubator T-S290NRI
Non-refrigerated Incubator is designed with a high precision microprocessor controller which maintains specific temperature control within the range of ambient +5 °C to 65 °C with an ...
Non-refrigerated Incubator T-S291NRI
Non-refrigerated Incubator is designed with a high precision microprocessor controller which maintains specific temperature control within the range of ambient +5 °C to 65 °C with an ...
Standards
ISO 11133:2014-Microbiology of food, animal feed and water-Preparation, production, storage and performance testing of culture media
Complies with the above standards, but is not limited to them.
Features
1. Benchtop non-refrigerated incubator for temperature-controlled incubation above ambient.
2. PID temperature control with digital display provides stable and uniform chamber temperature.
3. Natural or forced air convection options ensure consistent temperature distribution.
4. Suitable for microbiology, cell culture, biochemical and general laboratory incubation applications.
5. Adjustable shelving and transparent door allow sample organization and observation without heat loss.
FAQ
Q1: What testing scenarios is this incubator mainly applied to?
A: The non-refrigerated incubator is used in microbiology, molecular biology, biochemistry and general research laboratories for incubation of bacterial cultures, yeast cultures, biochemical reactions and sample conditioning at temperatures above ambient. It supports microbial culture growth, enzyme reaction incubation, antibody staining, sample preheating and general laboratory incubation where below-ambient temperature is not required. The stable temperature environment ensures reproducible culture growth and reaction kinetics.
Q2: What standards does the incubator comply with?
A: The incubator is designed with reference to IEC 61010 laboratory electrical safety standards and relevant GB/T standards for laboratory incubators. Specific applications follow their own culture or test protocols. Users should verify temperature uniformity and accuracy for critical applications.
Q3: What is the warranty period for the whole machine and key components?
A: The whole incubator is covered by a 12-month warranty. The heating element, controller, fan and temperature sensor are covered, while shelves and door gaskets are accessories. Damage from overheating, liquid spillage or unauthorized repair is excluded.
Q4: Is this device difficult to operate? Is professional training required?
A: Operation is simple: set the target temperature, allow stabilization and place samples inside. No professional training is required. Users should follow proper incubation protocols, avoid overcrowding the chamber and periodically verify temperature with a calibrated thermometer.
Q5: What is the typical lead-time for order delivery?
A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Q6: Is regular calibration required? What is the recommended calibration cycle?
A: Temperature calibration against a calibrated reference thermometer is recommended every 6-12 months, and more frequently for critical culture work. Temperature mapping of the chamber is recommended at installation and after relocation or maintenance to identify hot or cold spots.
Q7: Are supporting consumables universal? What about the long-term procurement cost?
A: There are no recurring consumables. Shelves and gaskets are standard accessories. Long-term ownership cost is low, with electricity being the main operational expense.
Q8: Can I customize parameters or supporting accessories?
A: Customization includes chamber capacity, temperature range, convection type and shelving configuration. Additional shelves, data loggers and access ports can be ordered separately. Custom orders extend delivery lead-time.
Q9: Does the purchase include on-site installation and commissioning service?
A: Standard delivery includes the incubator and shelves with an operation manual. No installation is required beyond placement and power connection. Remote commissioning guidance is provided. On-site service is not included for standard orders.
Q10: What types of samples are compatible with this equipment?
A: The incubator handles cultures, reagents and samples within the temperature range and chamber capacity. Volatile or flammable materials should not be incubated in a standard non-explosion-proof unit. Highly corrosive samples may damage the interior and require special lining. Users should ensure proper container sealing to prevent cross-contamination between samples.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.