Introduction

An ultrasonic homogenizer with the non-contact type is a homogenizer that processes the samples by the ultrasonic energy without the direct contact of the probe, and it is used in the biology, the pharmaceutical, the food, the research, and the many other applications. The non-contact ultrasonic homogenizer generates the ultrasonic waves, which are transmitted through the medium, such as the water, to the sample in the vessel, causing the cavitation and the disruption of the cells and the particles, without the probe touching the sample, and it reduces the cross-contamination; the non-contact ultrasonic homogenizer consists of an ultrasonic generator, a transducer, a coupling medium, a sample holder, and the controls, and it provides the homogenization, the lysis, and the dispersion, with features such as the adjustable power; the non-contact ultrasonic homogenizer is used for the cell lysis, for the homogenization of the samples, for the dispersion of the nanoparticles, for the extraction, for the preparation of the samples, and for many other applications, and it is an essential instrument for the sample processing. Non-contact ultrasonic homogenizers are used in the biology laboratories, in the pharmaceutical industry, in the food industry, in the research, and for many other applications. With their non-contact processing, non-contact ultrasonic homogenizers are essential for the contamination-free homogenization.

Ultrasonic Homogenizer (Non-T20ontact) LUHS-T2012

Ultrasonic Homogenizer (Non-T20ontact) LUHS-T2012



Ultrasonic Homogenizer (Non-contact) operates at a frequency of 19.5 to 20.5 KHz with automatic tracking. The device uses a Φ45mm probe horn for consistent and effective homogenization....
Ultrasonic Homogenizer (Non-T20ontact) LUHS-T2010

Ultrasonic Homogenizer (Non-T20ontact) LUHS-T2010



Ultrasonic Homogenizer (Non-contact) is a cup-form homogenizer with 700 ml disruption capacity. With 19.5 to 20.5 KHz operation frequency, it is used for disruption of cells, for emulsif...
Ultrasonic Homogenizer (Non-T20ontact) LUHS-T2011

Ultrasonic Homogenizer (Non-T20ontact) LUHS-T2011



Ultrasonic Homogenizer (Non-contact) is a cup-form homogenizer with 2 L disruption capacity. With 28 KHz ± 1 KHz operation frequency, it is used for disruption of cells, for emulsificat...

Standards

IEC 61010-2-051:2018-Particular requirements for laboratory equipment for mixing and stirring

Complies with the above standards, but is not limited to them.

Features

1. Non-contact ultrasonic homogenizer for indirect sample homogenization.

2. Ultrasonic energy transmitted through vessel wall without probe contact.

3. Suitable for biological, clinical, pharmaceutical, food and research laboratories.

4. Includes ultrasonic generator, transducer, sample holder, controller and manual.

5. Supports contamination-free homogenization, cell lysis and sample preparation.

FAQ

Q1: What testing scenarios is this homogenizer mainly applied to?

A: The non-contact ultrasonic homogenizer is used in biological research, clinical diagnostics, pharmaceutical development, food testing, environmental analysis and research laboratories to perform homogenization, cell lysis and sample preparation without direct probe contact, eliminating cross-contamination and enabling sterile processing. It supports microbial cell lysis for DNA/RNA extraction, clinical sample preparation for diagnostic testing, pharmaceutical sample homogenization in sterile containers, food sample preparation for analysis, environmental sample processing, and high-throughput sample preparation. The non-contact design transmits ultrasonic energy through the vessel wall, enabling contamination-free processing of multiple samples without probe cleaning between samples. It is essential for biological, clinical, pharmaceutical, food and research laboratories requiring non-contact ultrasonic homogenization for cell lysis, sample preparation, DNA/RNA extraction and contamination-free processing, where the indirect ultrasonic transmission through the vessel wall eliminates cross-contamination, enables sterile processing, supports high-throughput sample preparation, and reduces cleaning time in clinical, diagnostic, pharmaceutical and research applications requiring reliable, contamination-free sample homogenization and cell disruption.

Q2: What standards does the homogenizer comply with?

A: The non-contact ultrasonic homogenizer complies with relevant IEC 61010 laboratory electrical safety standards and applicable GB/T standards for laboratory equipment. Biological and clinical applications follow good laboratory practice and applicable biosafety guidelines. The instrument complies with relevant electromagnetic compatibility standards. Users should verify compatibility with their specific sample vessels and protocols.

Q3: What is the warranty period for the whole machine and key components?

A: The whole homogenizer is covered by a 12-month warranty. The ultrasonic generator, transducer, controller and housing are covered, while sample holders, vessels and fuses are consumables or accessories. Damage from improper use, incompatible vessels or unauthorized repair is excluded. Extended service contracts are available.

Q4: Is this device difficult to operate? Is professional training required?

A: Operation requires trained laboratory personnel familiar with ultrasonic homogenization, sample handling and biosafety. We provide operation manuals, training and application support. Proper vessel selection, parameter setting, sample handling and safety procedures are important for effective homogenization and safe operation.

Q5: What is the typical lead-time for order delivery?

A: Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

Q6: Is regular calibration required? What is the recommended calibration cycle?

A: Ultrasonic power and frequency verification recommended every 6-12 months. Transducer condition checked periodically. Sample holder compatibility verified. Routine cleaning recommended. Full system performance check annually. Sample vessel compatibility verified for new vessel types.

Q7: Are supporting consumables universal?

A: Sample vessels, holders and accessories are available from specialized suppliers, though compatibility with the homogenizer should be verified. Long-term consumable cost depends on sample volume and vessel type.

Q8: Can I customize parameters or supporting accessories?

A: Customization includes ultrasonic power, frequency, sample holder type, vessel compatibility, number of sample positions, control features and accessories. Additional holders and accessories can be ordered separately. Custom orders extend delivery lead-time.

Q9: Does the purchase include on-site installation and commissioning service?

A: Standard delivery includes the non-contact ultrasonic homogenizer and accessories with an operation manual. On-site installation, calibration and training are not included for standard orders but can be arranged for laboratory setup. Remote guidance is provided.

Q10: What types of samples are compatible with this equipment?

A: The non-contact ultrasonic homogenizer processes samples in compatible vessels (tubes, plates, vials) within the sample holder, power and frequency specification. The vessel material and thickness affect ultrasonic transmission; compatible vessels should be used. Different sample types (cells, tissues, chemicals) may require different parameters. Users should select compatible vessels for the holder, optimize parameters (power, time, pulse) for the sample type, follow proper biosafety procedures for biological samples, ensure proper sample volume in the vessel, and avoid overheating with pulse mode for heat-sensitive samples. The non-contact design eliminates probe contamination but may have lower energy efficiency than direct probe homogenizers, requiring longer processing times for some applications. For high-throughput use, proper vessel alignment and consistent sample volume are important for reproducible results. The instrument should be placed on a stable surface, and users should follow manufacturer guidelines for vessel compatibility to ensure effective ultrasonic transmission.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry