Introduction
Shaking incubator is a laboratory instrument designed for simultaneous incubation and agitation of samples, commonly used in microbiology, molecular biology, and cell culture applications. It provides a controlled environment with adjustable temperature settings, typically ranging from ambient to 70°C, and various shaking modes, such as orbital or reciprocal motion, to ensure uniform mixing and optimal growth conditions for biological samples. Shaking incubators are equipped with digital controls, often featuring programmable protocols and alarms, which enable researchers to maintain precise and consistent experimental conditions.
Vertical Shaking Incubator T-SI-S2202
Vertical Shaking Incubator T-SI-S2201
Vertical Shaking Incubator T-SI-S2200
Vertical Shaking Incubator T-SI-S2301
Vertical Shaking Incubator T-SI-S2103
Vertical Shaking Incubator T-SI-S2102
Vertical Shaking Incubator T-SI-S2101
Vertical Shaking Incubator T-SI-S2100
Horizontal Shaking Incubator T-SI-L2203
Horizontal Shaking Incubator T-SI-L2202
Horizontal Shaking Incubator T-SI-L2201
Horizontal Shaking Incubator T-SI-L2103
Horizontal Shaking Incubator T-SI-L2200
Horizontal Shaking Incubator T-SI-L2102
Horizontal Shaking Incubator T-SI-L2101
Horizontal Shaking Incubator T-SI-L2100
Bench-top Shaking Incubator T-SI-C204
Bench-top Shaking Incubator T-SI-C203
Bench-top Shaking Incubator T-SI-C202
Bench-top Shaking Incubator T-SI-C201
Bench-top Shaking Incubator T-SI-C200
Bench-top Shaking Incubator T-SI-C102
Bench-top Shaking Incubator T-SI-C101
Bench-top Shaking Incubator T-SI-C100
Shaking Incubator T-S211SI
Shaking incubator is an integrated unit with orbital shaking motion and PID controller for optimized temperature control. It is equipped with built-in door lock functions and air circulat...
Shaking Incubator T-S210SI
Shaking incubator is an integrated unit with orbital shaking motion and PID controller for optimized temperature control. It is equipped with built-in door lock functions and air circulat...
Standards
ISO/TS 23565:2021-Biotechnology-Bioprocessing-General requirements and considerations for equipment used in the manufacturing of cells for therapeutic uses
Complies with the above standards, but is not limited to them.
Features
1. Timer and continuous modes support unattended operation.
2. Smooth chamber and removable platform simplify cleaning.
3. Refrigerated models allow below-ambient incubation.
4. Combined temperature control and orbital shaking in one compact unit.
5. Interchangeable platforms and clamps hold various flask sizes.
FAQ
What is the Shaking Incubator mainly used for?
The Shaking Incubator combines controlled incubation with orbital shaking, supporting cell culture, microbiology, solubility and expression work that needs both temperature control and aeration. It is used in biotechnology, pharmaceutical and research laboratories.
What standards does the Shaking Incubator comply with?
The unit is designed with reference to IEC 61010 electrical safety requirements and relevant GB/T standards for incubators and laboratory mixing equipment. Compliance documentation can be provided on request.
What warranty comes with the Shaking Incubator?
We provide a 12-month limited warranty on the instrument and its key working parts. Consumables, accessories and parts subject to normal wear are excluded, as is damage caused by incorrect operation or maintenance. An extended service plan is available on request.
Will staff need special training?
No advanced specialist skills are needed for standard operation, though correct sample handling and safety practice should be followed. We supply a detailed manual and start-up support. For multi-user or regulated sites, a short staff training session can be arranged.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
How often should the Shaking Incubator be calibrated?
Factory calibration is included, and routine verification is recommended every 6 to 12 months using suitable reference materials. Regulated sites may require more frequent checks and documented records. Calibration support and certificates can be provided on request.
Where do we get replacement parts?
No proprietary consumable contract is required; standard parts are available from us and common laboratory suppliers. Our service team can supply a recommended parts list for the model. Most routine spares are held for quick delivery.
Can it be adapted to our requirements?
Yes, common options include different ranges, voltages, accessories, interfaces and capacity or size configurations. We confirm feasibility, specifications and any delivery impact before order confirmation. Custom requirements are reviewed case by case.
Do you provide on-site installation?
Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.
What maintenance and safety points matter?
Do not run flammable or highly volatile media or overload the platform beyond the rated load. Secure flasks properly and balance the load. Follow laboratory safety rules.