Introduction

Calorimeter delivers high performance with its wide temperature range, to ensure precise measurements. They feature high thermal insulation to minimize heat loss during operation. Their software interface adapts seamlessly to user needs for enhanced efficiency. Their data logging capabilities provide accurate, real-time recording and analysis. Our Calorimeter analyzes the thermal stability and phase transitions of materials.

Differential Scanning Calorimeter T-DSC-L2102

Differential Scanning Calorimeter T-DSC-L2102

Differential Scanning Calorimeter features -170 to 600 ℃ temperature range. Its liquid nitrogen cooling system combined with dual temperature control enables ultra-low operations. Its h...
Differential Scanning Calorimeter T-DSC-L2101

Differential Scanning Calorimeter T-DSC-L2101

Differential Scanning Calorimeter is equipped with -40 to 600 ℃ temperature range. Its high-sensitivity dual sensors and multi-point calibration enable reliable thermal measurements acro...
Differential Scanning Calorimeter T-DSC-L2100

Differential Scanning Calorimeter T-DSC-L2100

Differential Scanning Calorimeter works between room temperature to 600 ℃. Its high-frequency processor and optimized PID algorithm ensure faster response and stable condition. Its high-...
Automatic Bomb Calorimeter T-S2BC-S2102

Automatic Bomb Calorimeter T-S2BC-S2102

Automatic Bomb Calorimeter offers measurement accuracy of ≤60J/g. It features high-efficiency oxygen bomb with an advanced ignition system. Integrated with an auto-calibration function fo...
Differential Scanning Calorimeter T-DSC-S2101

Differential Scanning Calorimeter T-DSC-S2101

Differential Scanning Calorimeter offers a DSC range from 0 to ± 600mW with high sensitivity. It provides adjustable heating rates from 0.1 to 100℃/min, catering to various experimental ...
Differential Scanning Calorimeter T-DSC-S2105

Differential Scanning Calorimeter T-DSC-S2105

Differential Scanning Calorimeter provides 0 to ±800 mW range for comprehensive thermal analysis. Integrated with mechanical cooling method supports efficient temperature regulation. It f...
Differential Scanning Calorimeter T-DSC-S2104

Differential Scanning Calorimeter T-DSC-S2104

Differential Scanning Calorimeter offers 0 to ±600mW range measuring both small and large thermal variations. Integrated with liquid nitrogen cooling for rapid temperature changes and sta...
Differential Scanning Calorimeter T-DSC-S2103

Differential Scanning Calorimeter T-DSC-S2103

Differential Scanning Calorimeter is newly designed to ensure high resolution and high base line stability in the temperature range of RT to 550 ° C. An imported e-couple sensor offers ex...
Differential Scanning Calorimeter T-DSC-S2102

Differential Scanning Calorimeter T-DSC-S2102

Differential Scanning Calorimeter offers 0 to ±600 mW range detects transitions like melting, crystallization, and glass change. Equipped with -100°C to 800°C enabling analysis from cry...
Differential Scanning Calorimeter T-DSC-S2100

Differential Scanning Calorimeter T-DSC-S2100

Differential Scanning Calorimeter provides 0 to ±600 mW range for detailed heat flow measurements. Built in sturdy construction ensures easy installation and seamless integration into lab...
Automatic Bomb Calorimeter T-S2BC-L2101

Automatic Bomb Calorimeter T-S2BC-L2101

Automatic Bomb Calorimeter It is engineered for the precise measurement of the calorific value of both solid and liquid combustible materials. Accommodating a bomb volume of 282 ml and tak...
Automatic Bomb Calorimeter T-S2BC-S2101

Automatic Bomb Calorimeter T-S2BC-S2101

Automatic Bomb Calorimeter measures calorific values from 5 to 40 MJ/kg of water-free petroleum products. It provides complete analysis in 15 minutes, including water stabilization and mai...
Automatic Bomb Calorimeter T-S2BC-L2100

Automatic Bomb Calorimeter T-S2BC-L2100

Automatic Bomb Calorimeter It is engineered for the precise measurement of the calorific value of both solid and liquid combustible materials. Accommodating a bomb volume of 250 ml takes j...
Automatic Bomb Calorimeter T-S2BC-S2100

Automatic Bomb Calorimeter T-S2BC-S2100

Automatic Bomb Calorimeter provides 5 to 40 MJ/kg calorific range facilitates diverse testing for combustible materials. It completes a 6-minute water balance phase followed by an 8-minute...
Differential Scanning Calorimeter SC2053

Differential Scanning Calorimeter SC2053


Differential Scanning Calorimeter a compact, fully automatic device with a temperature range of 150℃ to 600℃. It operates using the heat flow differential scanning method for thermal an...
Differential Scanning Calorimeter SC2051

Differential Scanning Calorimeter SC2051


Differential Scanning Calorimeter provides accurate thermal analysis with an RT to 800°C temperature range and ±0.1°C accuracy. It measures heat flow differences to identify melting, c...
Differential Scanning Calorimeter SC2052

Differential Scanning Calorimeter SC2052


Differential Scanning Calorimeter operates within a temperature range from RT to 600°C. It offers advanced heating system to ensure uniform temperature distribution. Equipped with thermo...

Standards

Complies with the above standards, but is not limited to them.

Features

1. Safety devices protect against over-pressure during firing.

2. Clear software or display calculates calorific results.

3. Data storage and export support fuel certificates.

4. Automatic ignition and water handling improve repeatability.

5. Cooling and temperature control stabilise the baseline.

FAQ

What are the main applications of the Calorimeter?

The Calorimeter is used to measure heat-related values such as the calorific value of fuels or the heat content of reactions. It supports fuel specification, energy accounting, material research and quality control.

What standards does the Calorimeter comply with?

The instrument is designed with reference to applicable ASTM, ISO and GB/T calorific-value methods and IEC 61010 electrical safety. Procedures must follow the relevant standard. Compliance documentation can be provided on request.

What does the warranty cover?

The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.

How easy is the Calorimeter to use?

Day-to-day use is simple, with clear prompts and pre-set functions reducing manual steps. New operators should review the manual and complete a short familiarisation. Our technical team offers remote support during the first runs.

How long does delivery usually take?

Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.

How often should the Calorimeter be calibrated?

Factory calibration is included, and routine verification is recommended every 6 to 12 months using suitable reference materials. Regulated sites may require more frequent checks and documented records. Calibration support and certificates can be provided on request.

Are consumables and spare parts easy to obtain?

Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.

Can it be adapted to our requirements?

Customisation is supported for many installations, including tailored parameters, connections and accessories. Our team reviews the requirement and confirms feasibility and lead time in advance. We avoid committing to options that cannot be delivered reliably.

How is the Calorimeter commissioned?

Standard installation is straightforward and supported by the manual and start-up documentation. Our technical team can guide staff remotely through checks and validation. On-site commissioning is available as a quoted service.

What maintenance and safety points matter?

Do not overcharge the vessel, use incompatible samples or bypass pressure and temperature limits. Handle oxygen charging and ignition carefully. Follow laboratory safety rules.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

Inquiry