Introduction

Differential Scanning Calorimeter works between room temperature to 600 ℃. Its high-frequency processor and optimized PID algorithm ensure faster response and stable condition. Its high-sensitivity dual sensors enable simultaneous monitoring of furnace and sample temperature. It features independent atmosphere control with automatic air path switching for enhanced efficiency. Differential Scanning Calorimeter is ideal for process optimization, quality control and failure analysis of materials.

Manufactured under strict quality control processes, complying with international laboratory equipment standards. Provides 1-year warranty for main components and lifetime technical support.

Applications

Differential Scanning Calorimeter measures heat-related physical and chemical changes like glass transition, melting point, crystallization, oxidation induction, reaction kinetics, and specific heat in research and quality control processes.

Specifications

DSC Range 0 to ±2000 mW
Temperature Range Room temperature to 600 ℃
Sampling Rate 1 to 10 Hz (Programmable)
Toggle Rate 16.6 Hz
Heating Rate 0.1 to 100 ℃/min
Temperature Resolution 0.001 ℃ / 0.01 ℃
Temperature Fluctuation ±0.01 ℃
Temperature Repeatability ±0.01 ℃
Program Temperature Control 12-stage
Temperature Control Type Heating, constant temperature, cooling
Scan Type Heating, cooling, isothermal scanning
DSC Noise 0.001 mW
DSC Resolution 0.01 µW
DSC Accuracy 0.001 mW
DSC Sensitivity 0.001 mW
Gas flow rate 0 to 200mL/min
Gas pressure 0.2MPa
Power Supply 220V ,50 Hz
Dimension 490 × 390 × 215 mm
Gross Weight 35 Kg

Features

7-inch LCD touchscreen

Multi-Point Calibration 

Dual Experimental Modes 

Baseline Deduction Function

Auto Data Plotting

USB Bidirectional Communication

Standard Accessories

Model No

Accessory

Unit

Quantity

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:5.0cm;">

DSC System Host

Set

1

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;height:14.45pt;padding:0cm 5.4pt;vertical-align:top;width:5.0cm;">

Power Cord

Each

1

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:5.0cm;">

System Software USB

Each

1

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:5.0cm;">

Data Cable

Each

1

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:5.0cm;">

Aluminum Crucible

Each

100

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:5.0cm;">

Tweezers

Each

1

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:5.0cm;">

Fuses

Each

5

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:5.0cm;">

Trachea

Each

2

style="border-bottom:1.0pt solid windowtext;border-left-style:none;border-right:1.0pt solid windowtext;border-top-style:none;padding:0cm 5.4pt;vertical-align:top;width:5.0cm;">

Sample Spoon

Each

1

FAQs

1. What is a Differential Scanning Calorimeter?

A Differential Scanning Calorimeter is an apparatus designed to measure heat flow differences between a sample and a reference to analyze thermal transitions.

2. How does a Differential Scanning Calorimeter work?

It works by heating or cooling a sample and comparing its heat flow to that of a reference material to detect thermal events.

3. What materials can be analyzed using Differential Scanning Calorimeter?

It can analyze a wide range of materials, including polymers, metals, pharmaceuticals and liquids.

4. Can Differential Scanning Calorimeter analyze chemical reactions?

It can analyze chemical reactions by measuring the heat released or absorbed during the reaction.

5. Can Differential Scanning Calorimeter be used to study pharmaceutical formulations?

It is used to investigate the thermal behavior of pharmaceutical compounds, including melting points, stability and interactions between active ingredients and excipients.

6. Can Differential Scanning Calorimeter be used for biodegradable material research?

It is used to study the thermal properties of biodegradable materials, helping in the development of eco-friendly materials with specific thermal behaviors.

7. Can Differential Scanning Calorimeter be used in environmental studies?

It is used to analyze the thermal properties of materials in environmental applications, such as evaluating the thermal degradation of pollutants or studying biopolymer stability.

8. Can Differential Scanning Calorimeter be used to evaluate textile materials?

It is used to analyze the thermal behavior of textile materials, including their melting points and heat resistance.

9. Can Differential Scanning Calorimeter be used to study nanocomposites?

It is used to study the thermal properties of nanocomposites, such as their melting points, glass transitions, and curing behaviors.

10. What is the role of Differential Scanning Calorimeter in studying food packaging materials?

It is used to study the thermal behavior of food packaging materials, such as their melting and crystallization points, in order to ensure that they maintain food quality and prevent spoilage.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.