Introduction
Laboratory Fume Hood offers variation of Ducted, Ductless, PP Spray and Walk-In Fume Hoods. They are constructed with durable materials for corrosion resistance. These hoods come with a movable window that acts as physical barrier and controls the airflow. They are equipped with LED lighting for proper visibility. Our Laboratory Fume Hood provides a critical layer of protection for safe and efficient operations.
Stainless Steel Fume Hood SF2062
Stainless Steel Fume Hood with durable construction enhances longevity and resistance to corrosion. It features a work surface height of 800mm, offering ergonomic convenience. Equipped wi...
Stainless Steel Fume Hood SF2063
Stainless Steel Fume Hood with a work surface height of 800mm offers comfortable access to experiments. Equipped with an LED lamp, it ensures optimal visibility while working with sensiti...
Stainless Steel Fume Hood SF20620
Stainless Steel Fume Hood features an 800 mm work surface height for comfortable and efficient operation. Integrated air filtration system efficiently eliminates airborne contaminants. In...
Ducted Fume Hood FH2062
Ducted Fume Hood delivers optimal vertical surface for experiments with a maximum opening of 500 mm. It is constructed with high-quality steel plates for long-term use. Equipped with PP c...
Ductless Fume Hood DF2065
Ductless Fume Hood provides effective ventilation with an air velocity range of 0.4 to 0.6 m/s. It offers touch screen controls for easy and precise control. Integrated sensors continuous...
Ductless Fume Hood DF2063
Ductless Fume Hood is designed to maintain a safe working environment with a high airflow volume of 432 m³/h. It features an automatic airflow alarm system that promptly alerts users to ...
Ductless Fume Hood DF2064
Ductless Fume Hood provides a maximum opening of 650 mm, facilitating easy access to the work area. It maintains an air velocity between 0.4 to 0.6 m/s, providing consistent airflow. Inte...
Ductless Fume Hood DF2062
Ductless Fume Hood is designed to efficiently contain fumes with an airflow volume of 250 m³/h. It maintains a steady air velocity of 0.4 to 0.6 m/s, ensuring a consistent flow of air ac...
Walk-In Fume Hood WF2062
Walk-In Fume Hood is intended for large-apparatus applications with a maximum opening of 1300 mm. It is a large enclosure designed to isolate fumes, dust, gases, odours, and other harmful...
Walk-In Fume Hood WF2063
Walk-In Fume Hood is intended for large-apparatus applications with a maximum opening of 1300 mm. It is a large enclosure designed to isolate fumes, dust, gases, odours, and other harmful...
Walk-In Fume Hood WF20620
Walk-In Fume Hood is intended for large-apparatus applications with a maximum opening of 1300 mm. It is a large enclosure designed to isolate fumes, dust, gases, odours, and other harmful...
PP Spray Fume Hood PF2064
PP Spray Fume Hood is a custom-made fume hood with an exhaust volume of 1130m3/h designed to reduce perchloric acid residues. The inside of the deflector has a spray system that can neutr...
PP Spray Fume Hood PF2062
PP Spray Fume Hood is a custom-made fume hood with an exhaust volume of 700m3/h designed to reduce perchloric acid residues. The inside of the deflector has a spray system that can neutra...
PP Spray Fume Hood PF2063
PP Spray Fume Hood is a custom-made fume hood with an exhaust volume of 920m3/h designed to reduce perchloric acid residues. The inside of the deflector has a spray system that can neutra...
PP Spray Fume Hood PF20620
PP Spray Fume Hood is a custom-made fume hood with an exhaust volume of 560m3/h designed to reduce perchloric acid residues. The inside of the deflector has a spray system that can neutra...
Standards
ASHRAE 110-Method of Testing Performance of Laboratory Fume Hoods
Complies with the above standards, but is not limited to them.
Features
1. Airflow monitor or alarm indicates filter and fan status.
2. Low-noise fan supports comfortable working conditions.
3. HEPA filtration provides clean, controlled airflow over the work area.
4. Quiet fan and soft lighting support extended work sessions.
5. Filter condition indicators prompt planned replacement.
FAQ
What is the Laboratory Fume Hood mainly used for?
The Laboratory Fume Hood is used to provide clean or controlled airflow for handling samples, powders or operations that need protection from contamination or airborne exposure. It supports pharmaceutical, microbiological, analytical and electronics work.
What standards does the Laboratory Fume Hood comply with?
The unit is designed with reference to IEC 61010 electrical safety, applicable clean-air and containment standards and relevant GB/T methods. Filters and airflow should be tested periodically. Compliance documentation can be provided on request.
What warranty comes with the Laboratory Fume Hood?
The system is covered for 12 months after shipment, including the main mechanism and electrical controls. Replaceable consumables and routine service items are not part of the warranty. Faults caused by improper installation outside the manual or unauthorised modification are not covered.
Will staff need special training?
Routine operation is straightforward and is covered in the user manual, including setup, daily use and basic maintenance. Staff with basic laboratory experience can run it after a short familiarisation. We provide remote guidance and can arrange on-site training where required.
How long does delivery usually take?
Standard models require 7-30 working days. In-stock units can ship within 3-7 working days. Custom configurations or large built-to-order systems may require additional time, and we confirm the exact schedule before order confirmation.
Does the Laboratory Fume Hood need calibration or verification?
Factory calibration is included, and routine verification is recommended every 6 to 12 months using suitable reference materials. Regulated sites may require more frequent checks and documented records. Calibration support and certificates can be provided on request.
Are the consumables universal or proprietary?
Filters, seals, probes and similar items are standard and can be supplied through our channel. Customers may also source equivalent items that meet the specification. Provide the model and serial number to confirm compatibility before ordering.
Are options or configurations available?
Customisation is supported for many installations, including tailored parameters, connections and accessories. Our team reviews the requirement and confirms feasibility and lead time in advance. We avoid committing to options that cannot be delivered reliably.
Is installation and commissioning included?
Benchtop and standard units typically require only placement and connection before use, while larger systems may need professional commissioning. We confirm the installation requirements at order stage. On-site service and training can be provided if needed.
What maintenance and safety points matter?
Do not handle highly toxic or pathogenic agents beyond the containment class, block the face opening or rely on expired filters. Verify airflow and filter integrity. Follow laboratory safety rules.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.