Introduction

Analytical System deliver a flow rate range of 0.0000 to 12.0000 mL/min  ensuring precise solvent delivery for diverse analytical applications. The system offers a comprehensive detector range including UV, , , , and managed with intelligent control. It features obstacle protection and empty bottle detection to prevent needle damage and invalid sample injection. The system uses innovative technology to identify shoulder and small peaks in chromatographic analysis. Our Analytical is ideal for precise separation and detection of complex mixtures in pharmaceuticals, chemicals, and biotechnology research.

This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Analytical System is ideal for quantitative and qualitative analysis in pharmaceuticals, biotechnology, and chemical industries. It is widely used for purity testing, component identification, and trace compound detection in complex mixtures.

Specifications

Flow Rate Setting Range 0.0000 to 12.0000mL/min
Flow Rate Setting Increment 0.0001mL/min
Gradient Error Less than equal to 0.75%
Gradient Stability 0.2% (5% to 95%, 0.2 to 2.0mL/min)
Flow Rate Setting Value Error ± 0.20%
Flow Rate Stability Less than equal to 0.075%
Maximum Operating Pressure 62MPa /75MPa
Autosampler Linearity R ≥ 0.9999 (1.0μL to 50μL)
Autosampler Cross Contamination Less than equal to 0.002%
Number Of Injection Bits 108 bits (2 ×54, 2mLsample bottle)
Injection Mode flow to needle
Injection Volume 100μL, 200μL, 500μL, 1000μL, 1500μL, 2000 μL
Repeatability Less than 0.3 % (2μL to Max)
Less than 1.0 % (0.1μL to 1.9μL)
Linear Correlation Coefficient Greater than 0.9999
Number of Sample Position 108 (2×54, 2mL), 96-well plates
Temperature Setting Range 4 to 40 ℃ (optional refrigeration)
Temperature Setting Value Error ±0.5℃ (optional refrigeration)
Temperature Stability ±0.5℃ (optional refrigeration)
Column Oven Temperature Range 4℃ to 90℃
Column Oven Temperature Stability ± 0.03℃/h
Column Oven Temperature Setting Value Error ± 0.1℃
Power Supply 220V ±10%, 50–60Hz
Autosampler Dimension 930 × 520 × 570 mm
Column Oven Dimension 690 × 520 × 550 mm
Pump & Detector Dimension 830 × 520 × 430 mm
Fluorescence Detector Dimension 640 × 480 × 400 mm
Refractive Index Detector Dimension 640 × 470 × 400 mm
Electrochemical Detector Dimension 610 × 520 × 370 mm
Autosampler Weight 51 Kg
Column Oven Weight 32 Kg
Pump & Detector Weight 32.2 Kg
Fluorescence Detector Weight 37.5Kg
Refractive Index Detector Weight 29.5 Kg
Electrochemical Detector Weight 28.5 Kg
Total Weight 232 Kg

Features

Modular system design

Multiple detector options

Optimized needle cleaning

User-friendly workstation

Automated injection control

FAQs

1. What are the key factors to consider when selecting this analytical equipment for laboratory use?

When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this analytical equipment be calibrated to ensure accurate results?

It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this analytical equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the analytical equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.