Introduction
Type II RO Water Purification System operates efficiently with a feed water conductivity of less than 2000 µS/cm. It features fully automatic microcomputer control for reliable operation. The system includes an automatic membrane cleaning function for longer membrane life. It is equipped with advanced a cylindrical, multi-functional water tank for laboratory needs. Our Type II RO water purification system is ideal for sample dilution, standard solution preparation, and microbiological media formulation.
This water purification system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Type II RO water purification system is ideal for sample dilution, standard solution preparation, microbiological media formulation, glassware cleaning, autoclave supply, and as feed water for ultrapure systems.
Specifications
| Type | Benchtop System |
| Water Requirements | Tap Water |
| Feed Water Conductivity | < 2000 µS/cm |
| Feed Water Hardness | < 450 ppm as CaCO3 |
| Feed Water Temperature | 5°C to 40°C |
| Water Inlet Pressure | 0.05 to 0.5 MPa |
| Ion Rejection Rate | > 95% |
| Bacterial Rejection | > 99% |
| Water Conductivity | < 1 to 20 µS/cm |
| Productivity Rate | 30 L/h |
| Power Supply | 110 V to 220 V / 50 HZ to 60 HZ ± 10% |
| Dimensions (Main Unit) | 315 × 525 × 570 mm |
| Dimensions (Water Tank) | 380 × 380 × 595 mm |
| Packaging Dimensions (Main Unit) | 525 × 610 × 770mm |
| Packaging Dimensions (Water Tank) | 520 × 440 × 615mm |
| Net Weight (Main Unit) | 21 Kg |
| Net Weight (Water Tank) | 5 Kg |
| Gross Weight (Main Unit) | 34 kgs |
| Gross Weight (Water Tank) | 15 kgs |
Features
Advanced Pretreatment Design
Integrated Filling Technology
Premium RO Membrane
Tool-Free Cartridge Replacement
Durable Build Quality
FAQs
1. What makes the Type II RO Water Purification System easy to install?
The Type II RO Water Purification System is designed as a plug-and-play solution that integrates easily into laboratory setups. Its compact benchtop form eliminates the need for large dedicated spaces or complex infrastructure modifications. Standard connections for water inlet and outlet simplify installation, allowing the system to be operational with minimal setup time. The unit is compatible with common electrical supply standards, further easing integration. Clear documentation and user guides help operators get started quickly and confidently. This ease of installation makes it an accessible solution for both new and existing laboratories.
2. What key features does the Type II RO Water Purification System offer?
The Type II RO Water Purification System offers advanced reverse osmosis purification with high ionic and bacterial rejection. It includes automatic membrane cleaning, which helps extend membrane life and maintain performance. The system features a user-friendly interface for simple operation and monitoring. A multi-functional cylindrical tank provides convenient water storage and dispensing. Its compact benchtop design saves valuable laboratory space. The robust build ensures durability and consistent operation over time.
3. How does the Type II RO Water Purification System ensure water quality?
The Type II RO Water Purification System uses a premium reverse osmosis membrane with flow limitation design to achieve high rejection rates. Every drop of water passes through activated carbon and advanced pretreatment stages. The system effectively removes residual chlorine, organic contaminants, and particulates. Real-time monitoring of key parameters ensures water consistently meets Type II standards. Automatic cleaning cycles help prevent membrane fouling and maintain performance. Together, these features provide consistent and dependable water purity for lab needs.
4. How does the Type II RO Water Purification System support eco-friendly practices?
The Type II RO Water Purification System is engineered to reduce water and energy consumption during operation. Its membrane cleaning function reduces waste by maintaining membrane efficiency over time. The system’s design minimizes reject water generation where possible. Low power consumption components contribute to more sustainable lab operations. Compact design means reduced material use during manufacturing. All these factors help labs align with green lab initiatives.
5. Is the Type II RO Water Purification System suitable for space-limited labs?
The Type II RO Water Purification System is well-suited for labs where space is at a premium. Its compact benchtop design allows it to fit easily onto standard work surfaces without requiring dedicated floor space. The system combines water production and storage in a single unit, further saving space. Its cylindrical water tank design optimizes capacity while minimizing footprint. Simple connections and minimal external components contribute to its efficient use of space. This makes it ideal for both large labs and smaller facilities with limited room.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.