Mortuary Refrigerator is a high-capacity, stainless steel storage solution with 6 independent chambers. This mortuary refrigerator offers a 200kg load capacity per tray. It provides precise temperature control and is designed for long-term preservation. This features a 100 mm-thick urethane foam insulation for superior energy efficiency and temperature stability. Our monitors seven critical conditions to ensure uninterrupted operation and safety. Perfect for preserving remains with hygiene and security.
This medical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Mortuary Refrigerator is ideal for hospitals, morgues, and funeral homes, providing secure, hygienic storage for remains. Its stainless-steel construction and advanced alarm system ensure reliability for long-term preservation, making it suitable for both fixed installations and flexible use in emergency or temporary facilities.
Specifications
| Material | 304 Stainless Steel (201/216 optional) |
| Stainless Steel Thickness (Body Tray) | 3.0 mm |
| Stainless Steel Thickness (Exterior) | 1.0 mm |
| Compressor Location | Top-mounted |
| Compressor Type | Germany /Danfoss (optional) |
| Number of Compressors | 6 (independent per chamber) |
| Refrigerant | R404A |
| Temperature Range | Standard: 0°C to -10°C |
| Temperature Accuracy | ±1°C |
| Working Ambient Temp | 10°C to 38°C |
| Insulation Thickness | 100 mm (urethane foam) |
| Chamber Height | 460 mm |
| Number of Trays | 6 |
| Number of Doors | 6 |
| Body Tray Dimensions | 1940 mm × 360 mm |
| Tray Load Capacity | 200 kg per tray |
| Wheel Type | 5-inch universal (maintenance-free nylon rollers) |
| Alarm Types | 7 (high/low temp, power failure, sensor error, etc.) |
| Power Rating | 1369 W / 1.2 A |
| Voltage | 220-240V |
| Packing Dimensions | 2140 mm × 1450 mm × 2037 mm |
| Weight | 640 kg |
| Gross Weight | 680 Kg |
Features
High-Capacity Storage
Precision Temperature Control
Durable Construction
Top-Tier Cooling System
Advanced Safety Alarms
Secure & Mobile Design
FAQs
1. What are the key factors to consider when selecting this medical equipment for laboratory use?
When selecting this medical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this medical equipment be calibrated to ensure accurate results?
It is recommended to calibrate this medical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this medical equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this medical equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this medical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the medical equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.