Introduction
Ultrapure Water System produces Class pure water with ionic rejection rates over 95%. Its one-piece thermal molding design ensures safety and leak-free performance. A high-recovery composite membrane provides extended service life. The pressure-resistant structure further prevents leakage during operation. Our Ultrapure Water system is ideal for molecular biology applications such as , cell and tissue culture, and electrophoresis, where contamination-free water is essential.
This water purification system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Ultrapure Water System supports applications like nanoparticle synthesis, immunohistochemistry, flow cytometry, toxicology studies, and veterinary diagnostics, offering ideal and consistent water quality for highly sensitive and cross-disciplinary experimental requirements.
Specifications
| Source | Tap water |
| Conductivity | < 2000 us/cm |
| Hardness | < 450 ppm as CaCO3 |
| Water Temperature | 5 ℃ to 40 ℃ |
| Water Pressure | 0.05 to 0.5 MPa |
| Class I Resistivity (25 ºC) | 18.2 MΩ.cm |
| Class I Water Conductivity (25 ºC) | 0.055 us/cm |
| Class I Water Total Organic Carbon Level | 1 to 5 ppb |
| Class I Particulate Matter | < 1 pc/ml |
| Manual Dispense Flow Rate | 1.5 to 2.0 L/min |
| Automatic Dispense Volume | 100 to 60000 ml |
| Electrical Voltage | 110 V/220 V±10% |
| Electrical Frequency | 50 HZ/60 HZ |
| External Dimension (Main Units) | 315 × 525 × 570 mm |
| External Dimension (Water Tank) | 380 × 380 × 595 mm |
| Net Weight (Main Units) | 24 Kg |
| Net Weight (Water Tank) | 7 Kg |
Features
Tap Water Compatibility
Inlet Pressure Monitoring
Dual Dispensing & Recirculation
Adjustable Dispenser Height
Endotoxin Removal Filter
FAQs
1. Does the Ultrapure Water System support data logging or connectivity features?
The Ultrapure Water System is designed with a RS232 interface that enables data logging and integration with lab monitoring systems. This feature allows users to track water usage, quality metrics, and maintenance records digitally. Data can be exported for compliance documentation or internal audits. This makes it easier to maintain quality control, especially in regulated lab environments like , , or -certified laboratories. Advanced models may offer additional connectivity options depending on configuration. This improves traceability and ensures adherence to laboratory best practices.
2. How does Ultrapure Water System maintain water purity during idle periods?
During periods of inactivity, water inside the system may become stagnant and prone to microbial growth. The Ultrapure Water System minimizes this risk through auto-flush functions, which periodically circulate water through the purification loop. This helps keep the internal system clean and reduces biofilm formation. Users are also advised to dispense a small amount of water after long idle periods to flush out stagnant water. For extended shutdowns, it's recommended to perform a manual sanitization cycle or drain the system as per the user manual. These built-in features and best practices help ensure water quality is maintained even when not in regular use.
3. Can the Ultrapure Water System be upgraded with additional purification modules?
Yes, the Ultrapure Water System is designed with a modular architecture, allowing it to be customized or upgraded with optional components like ultrafiltration (UF) modules, units, or additional UV/ reduction stages. This flexibility makes it ideal for labs that may expand their research scope in the future. Adding modules can improve microbial control, reduce endotoxins, or further lower depending on lab needs. The upgrade process is generally straightforward and can often be done without replacing the entire system. This extendable design makes it a long-term investment for growing labs.
4. How does the Ultrapure Water System ensure the accuracy of its water quality readings?
The Ultrapure Water System uses high-precision sensors to monitor resistivity and conductivity continuously during water production. These sensors are factory-calibrated and located at the final water outlet to ensure readings reflect the actual water being dispensed. The system’s microprocessor performs self-checks and alerts users if a sensor is malfunctioning or if values fall outside of acceptable ranges. Regular calibration checks are recommended for labs with strict quality control needs. By placing the sensors in-line and after the purification process, the system delivers accurate, real-time water quality data. This gives users confidence in the reliability of their experimental results.
5. Can the Ultrapure Water System be used with external storage tanks?
Yes, the Ultrapure Water System can be connected to an external storage tank, which allows users to maintain a larger reserve of purified water. This is especially useful during peak usage periods or in shared lab environments. The system includes level detection sensors to prevent overfilling and ensure safety. It can also automatically refill the tank when levels drop below a preset threshold. This compatibility makes the unit suitable for labs with fluctuating water demands. External tanks with UV protection and sterile vent filters are recommended to maintain water quality during storage.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.