Introduction
Ultrapure Water System is designed to operate using tap water with a conductivity below 2000 µs/cm. It removes particulates, ions, organics, and microbes. A user-friendly display shows real-time system and water quality status. Its compact design ensures space efficiency and reliable use. Our Ultrapure Water System delivers pyrogen-free ultrapure water for cell culture, protein work, , , and electrophoresis.
This water purification system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Ultrapure Water System supports , IC, GC, molecular biology, , / analysis, cell culture, protein purification, diagnostics, and reagent preparation with ultra-low , ensuring reliable, contamination-free results.
Specifications
| RO Production Rate | 15 L/h |
| Source | Tap water |
| Conductivity | < 2000 us/cm |
| Hardness | < 450 ppm as CaCO3 |
| Water Temperature | 5 ℃ to 40 ℃ |
| Water Pressure | 0.05 to 0.5 MPa |
| Class Ionic Rejection | > 95% |
| Class Bacteria Rejection | > 99% |
| Class I Resistivity (25 ºC) | 18.2 MΩ.cm |
| Class I Water Conductivity (25 ºC) | 0.055 us/cm |
| Class I Particulate Matter | < 1 pc/ml |
| Class I Water Total Organic Carbon Level | 1 to 5 ppb |
| Manual Dispense Flow Rate | 1.2 to 1.5 L/min |
| Automatic Dispense Volume | 100 to 60000 ml |
| Electrical Voltage | 110 V/220 V±10% |
| Electrical Frequency | 50 HZ/60 HZ |
| External Dimension (Main Units) | 315 × 525 × 570 mm |
| Packaging Dimensions | 610 × 525 × 745mm |
| Net Weight (Main Units) | 32 kg |
Features
-Protected Settings
Dual Cartridge System
Leak-Proof Design
Quick-Connect Cartridge Replacement
Customized Pre-Filtration Option
FAQs
1. Is Ultrapure Water System wall-mounted?
Yes, Ultrapure Water System is structurally designed for wall mounting, making it ideal for compact and efficient laboratory installations.
2. Does Ultrapure Water System have protective and safety features?
Yes, Ultrapure Water System complies with 61010-1 safety standards and the Directive 2014/30/EU, ensuring reliable operational safety in laboratory environments.
3. Does Ultrapure Water System have a water sensor that shuts off supply in case of leakage?
Yes, Ultrapure Water System is equipped with a water leakage sensor that automatically shuts off the feed water in case of floor-level leakage detection.
4. Does Ultrapure Water System have a tank level sensor to control water production?
Yes, Ultrapure Water System features an internal 6.5-liter tank with three programmable water levels to control production based on user-defined settings.
5. Does Ultrapure Water System include an air block mechanism to prevent air entry?
Yes, Ultrapure Water System uses a point-of-use filter that serves as an air block mechanism, preventing air intrusion into ultrapure water lines.
6. Are accessories like ion-exchange resins and cleaning reagents included?
Yes, Ultrapure Water System is supplied with a full set of pre-installed consumables, including cartridges and reagents. User can connect the power and water for direct usage.
7. How does the Ultrapure Water System help ensure accurate chemical solution preparation?
Accurate solution preparation requires consistent water purity, free of contaminants that may alter solute concentration or pH. The Ultrapure Water System provides stable water quality with continuously monitored parameters such as resistivity and . Its integrated purification stages ensure low ionic and organic content, making it ideal for standard and volumetric solution preparation. Consistency in water quality minimizes variation across experimental batches. The system also reduces the risk of introducing background interference in analytical techniques like titration, spectrophotometry, or chromatography. This level of purity is vital for reproducible results and proper calibration.
8. Can ultrapure water from Ultrapure Water System be used in trace analysis or elemental detection?
Yes, the ultrapure water produced by Ultrapure Water System is well-suited for trace metal analysis and elemental detection techniques like , -, or -MS. These applications require extremely low background contamination, especially from trace metals or organics. The system’s multi-stage purification process, including advanced ion exchange and membrane technologies ensures the removal of interfering substances. Its high-purity output supports sensitive detection at parts-per-trillion levels. Additionally, closed-circuit design minimizes recontamination during dispensing.
9. How does the Ultrapure Water System support consistency in reagent and standard solution preparation over time?
Consistency in reagent and standard solution preparation relies heavily on water quality remaining stable over time. The Ultrapure Water System includes real-time monitoring and alarms to notify users of any deviations in water parameters. Automated flushing and self-cleaning mechanisms help preserve performance and extend component life. High-capacity cartridges reduce the frequency of maintenance and reduce variability in water output. This results in uniform water quality that supports reliable preparation from one batch to the next. Consistent purity is essential for calibration standards, buffer preparation, and reproducible lab results.
10. What role does ultrapure water play in minimizing contamination during laboratory workflows?
Ultrapure water acts as a baseline solvent and rinse medium in many lab workflows, making its purity directly tied to contamination control. Using substandard water can introduce particles or biological agents that compromise experimental integrity. Genius-Lite minimizes this risk by eliminating bacteria, organics, ions, and particulates through a layered purification approach. It supports clean rinsing of labware and tools, preventing residue buildup or cross-contamination between experiments. For sensitive workflows like nucleic acid handling or protein purification, such high purity is essential. This results in higher success rates and reproducible outcomes.
11. How does ultrapure water improve the accuracy of pH-sensitive reagent preparation?
Ultrapure water ensures that there are no interfering ions or buffer residues that could alter the pH of prepared solutions. For pH-sensitive reagents or buffers, even small traces of acid/base contaminants can shift the pH value significantly. The Genius-Lite system delivers consistent high-purity water with minimal ionic content, providing a stable base for pH calibration and formulation. This allows lab technicians to achieve the desired pH without compensating for unknown impurities. Additionally, the system’s real-time conductivity monitoring helps verify that water quality is suitable for such precise preparations. Accurate pH formulation is critical for enzymatic reactions, cell culture buffers, and analytical reagents.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.