Introduction

Ultrapure Water System operates on a dual voltage of 110V/220V ±10%, ensuring compatibility with various power supplies. It features an ergonomic remote dispenser with a 25 cm dispensing radius for convenient usage. The system supports multiple installation options, including wall mounting. It delivers high-purity water for sensitive applications. Our Ultrapure Water System is ideal for molecular biology, cell and tissue culture, and / analysis, and protein purification.

This water purification system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Ultrapure Water System is ideal for analytical chemistry, , protein purification, and instrument feed water applications, providing reliable, consistent, and contaminant-free results essential for high-precision laboratory operations.

Specifications

Source Tap water
Conductivity < 2000 us/cm
Hardness < 450 ppm as CaCO3
Water Temperature 5 ℃ to 40 ℃
Water Pressure 0.05 to 0.5 MPa
Class I Resistivity (25 ºC) 18.2 MΩ.cm
Class I Water Conductivity (25 ºC) 0.055 us/cm
Class I Water Total Organic Carbon Level 1 to 5 ppb
Class I Particulate Matter < 1 pc/ml
Manual Dispense Flow Rate 1.5 to 2.0 L/min
Automatic Dispense Volume 100-25000 ml
Electrical Voltage 110 V/220 V±10%
Electrical Frequency 50 HZ/60 HZ
External Dimension (Main Units) 315 × 520 × 560 mm
External Dimension (Water Tank) 380 × 380 × 595 mm
Net Weight (Main Units) 26 Kg
Net Weight (Water Tank) 7 Kg

Features

Removable dispensing pistol

Advanced Electrode ionization () features

Chemical-Free Operation

Reduced Wastewater Generation

Low Heat Rejection

FAQs

1. What type of water quality does the Ultrapure Water System deliver, and how is it suitable for sensitive laboratory applications?

The Ultrapure Water System delivers ultrapure water with a resistivity of up to 18.2 M?·cm and levels as low as 1–5 ppb. It also ensures RNase-, DNase-, and endotoxin-free water, which is crucial for molecular biology and -based experiments. This high level of purity prevents contamination that could compromise sensitive assays. The system uses advanced purification technologies, including reverse osmosis, electrode ionization (), UV sterilization, and 0.22 µm filtration. This makes it ideal for applications such as / sequencing, cell culture, and protein purification. The water meets or exceeds Type I standards, supporting even the most critical lab processes.

2. How does the Ultrapure Water System maintain consistent water quality over time?

The Ultrapure Water System is equipped with real-time conductivity and temperature sensors that continuously monitor output water quality. It uses a multi-stage purification system that includes RO membranes, UV lamps for reduction, and a final point-of-use filter to ensure the highest purity. A built-in recirculation loop keeps the water moving, which prevents microbial growth and reduces stagnation. Electrode ionization modules maintain ion removal efficiency without the need for chemical regeneration. Additionally, the automatic flushing feature helps extend the life of the internal components. These integrated technologies work together to ensure stable and consistent ultrapure water output.

3. Can the Ultrapure Water System be integrated into existing laboratory setups, and what are the installation options?

Yes, the Ultrapure Water System offers flexible installation options including benchtop, wall-mounted, or under-bench configurations. Its compact design allows easy integration into laboratories with limited space. The system supports remote dispensing, which provides further flexibility in placing the unit. Inlet water connections are compatible with various lab plumbing standards, and setup is straightforward with clear installation guidance. It also supports dual-voltage operation (typically 110V/220V ±10%), making it adaptable to global power requirements. These features make it an excellent choice for both new and existing lab environments.

4. How does the Ultrapure Water System ensure microbial control and prevent contamination during operation?

The Ultrapure Water System is equipped with multiple features to ensure superior microbial control. It includes a built-in UV sterilization lamp (typically 185/254 nm) that continuously eliminates organic contaminants and suppresses microbial growth. The recirculation loop design ensures that water doesn’t stagnate, which further reduces the risk of microbial buildup. Additionally, the final 0.22 µm filter at the point of use provides an additional barrier against bacteria and particulates. The system automatically performs flushing cycles to maintain hygiene in the internal lines. These measures collectively ensure that the water remains RNase-free, DNase-free, and endotoxin-free, ideal for critical applications like and cell culture.

5. What type of display and user interface is used in the Ultrapure Water System ?

The Ultrapure Water System features a modern, digital touchscreen interface that allows intuitive control and monitoring of all system parameters. Users can easily view key metrics such as water quality (resistivity/conductivity), temperature, tank level, and dispensing volume. The interface supports setting programmable volume dispensing with high precision, allowing users to automate repetitive tasks. It also provides visual and audible alerts for cartridge replacement, low pressure, leakage, or UV lamp faults. The menu is password-protected to prevent unauthorized changes to system settings. Its user-friendly design makes it suitable for researchers and lab technicians of all experience levels.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.