Ultrapure Water System operates efficiently on electrical voltages of 110V or 220V. It uses Reverse Osmosis (RO) and Electrode ionization () in a multi-stage system for high-quality water purification. The system supports remote control functionality via an RS232 interface. It delivers Type II water suitable for critical laboratory applications. Our ultrapure water system is ideal for microbiological analysis, pH measurement, and histology.

This water purification system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Ultrapure Water System is ideal for scientific processes such as atomic absorption spectrophotometry ( and ), spectrophotometry, electrophysiology, and other applications requiring high-purity water and precision.

Specifications

Source Tap water
Conductivity < 2000 us/cm
Hardness < 450 ppm as CaCO3
Water Temperature 5 ℃ to 40 ℃
Water Pressure 0.05 to 0.5 MPa
Class II Water Resistivity (25ºC) 10 MΩ.cm
Class II Water Total Organic Carbon Level < 30 ppb
Class II Dissolved Organic < 0.1 ppm
Class II Productivity Rate 15 L/h
Electrical Voltage 110 V/220 V ±10%
Electrical Frequency 50 HZ/60 HZ
External Dimension (Main Units) 314 × 525 × 570 mm
External Dimension (Water Tank) 380 × 380 × 595 mm
Net Weight (Main Units) 32 Kg
Net Weight (Water Tank) 7 Kg

Features

Advanced Technology

User-Friendly Design

Superior Purification Performance

One-click sanitization function

Automatic Monitoring System

FAQs

1. Can the Ultrapure Water System be used for microbiological analysis and histology?

Yes, the Ultrapure Water System is well-suited for applications such as microbiological analysis and histological procedures. The water produced is free from RNase, DNase, and endotoxins, making it safe for delicate biological work. Its consistent water quality minimizes the risk of contamination, which is critical for accurate staining, sample preservation, and microbial culture growth. The system's multi-stage filtration ensures removal of bacteria and organic residues that could interfere with biological observations or results. Laboratories focused on tissue processing, slide preparation, or microbial testing will benefit from the high reliability of the water output. Additionally, the system includes features like automatic sanitization and remote monitoring to maintain purity levels over time. This makes it a dependable solution for daily lab workflows requiring sterile and high-purity water.

2. What filtration technologies are used in the Ultrapure Water System ?

The Ultrapure Water System incorporates a multi-stage purification system that includes Reverse Osmosis (RO) and Electrodeionization () technologies. RO removes up to 99% of dissolved salts, organic material, and particles, serving as the primary filtration stage. Following this, continuously polishes the RO water by removing residual ions without the need for chemical regenerants. This combination ensures a steady supply of high-purity water while reducing operational costs and downtime. The module also provides consistent quality without interruptions, making it ideal for laboratories that operate around the clock. Additionally, optional UV sterilizers and final filters are available to target microbial contaminants and (Total Organic Carbon) levels. This layered approach guarantees both chemical and biological purity in every drop of water.

3. Is remote monitoring available with this Ultrapure Water System ?

Yes, Ultrapure Water System supports remote monitoring capabilities via an RS232 interface. This allows users to connect the system to a computer or laboratory management system for data logging, alerts, and real-time status updates. With this feature, labs can maintain operational oversight even when the unit is placed in restricted or low-access areas. The system continuously tracks key parameters such as resistivity, conductivity, and flow rate to ensure stable performance. Remote access reduces the need for manual checks and helps identify any anomalies early, preventing disruptions in lab processes. Additionally, software integration can assist with audit trails or regulatory compliance for labs that require documentation. It’s a user-friendly feature that enhances convenience, especially in high-throughput or multi-user environments.

4. What is the water output capacity and how does it impact lab performance?

The Ultrapure Water System typically delivers purified water at a flow rate of up to 30 liters per hour, which is suitable for medium to large laboratory operations. This capacity supports continuous water availability for processes like glassware rinsing, reagent preparation, and sample analysis. The system ensures that water production meets demand without the need for additional storage tanks or manual refills. Stable output prevents workflow delays, especially during peak lab hours. Consistent flow also helps in maintaining water quality since stagnant water can lead to microbial growth. The system's integrated monitoring helps regulate output to match consumption, ensuring efficiency and minimal waste. This output capacity makes the Deluxe-E Series a practical and scalable solution for dynamic laboratory environments.

5. How does the one-click sanitization function help maintain water purity?

The one-click sanitization function simplifies system hygiene by initiating a complete internal cleaning cycle at the press of a button. This automated process disinfects the internal water lines, removing microbial growth, biofilm, and other contaminants that could affect water purity. It significantly reduces manual cleaning efforts, helping users maintain consistent performance and extend component lifespan. Routine use of this function prevents system fouling and supports compliance with laboratory cleanliness standards. The feature is especially useful in shared lab environments or high-throughput settings where hygiene control is essential. It enhances the reliability of water quality without requiring deep technical knowledge from the operator. With this function, maintaining high-purity water becomes both efficient and user-friendly.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.