Introduction

Heated is a compact design with a temperature range of -10 °C to 100 °C. It features a multi-point operation mode for enhanced precision and efficiency. The incubator incorporates an adjustable heating lid, which ensures uniform heat distribution and prevents sample evaporation. Its integrated temperature sensor and heating/cooling function deliver rapid and accurate temperature control. Our Incubator is widely used for sample incubation, nucleic acid denaturation, enzyme reactions, and preparation.

It provides a stable and controlled environment for cell culture, microbial growth, and other biological experiments. The precise temperature and humidity control ensure consistent experimental conditions and reliable results.

Applications

Our Heated Lid Dry Bath Incubator is ideal for sample incubation, nucleic acid denaturation, enzyme reactions, and preparation. The integrated heating lid makes it especially suitable for processes involving tubes and microplates, minimizing condensation and improving reaction stability. Its interchangeable block compatibility makes it a flexible tool for molecular biology, clinical diagnostics, and biochemical laboratories.

Specifications

Temperature Setting Range -10 °C to 100 °C
Temperature Control Range RT -25 ℃ to 100 ℃
Temperature Accuracy Up to ±0.3 ℃ at 37 ℃
Temperature Uniformity Up to ±0.3 ℃ at 37 ℃
Heating Time Up to 12 min (from 25 ℃ to 100 ℃)
Cooling Time Up to 12 min (from 100 ℃ to 25 ℃)
Up to 25 min (from RT to RT -25 ℃)
Timing Range 1 sec to 99 h 59 min/ ∞
Heating Lid Temperature Setting Range to +10 ℃
Heating Lid Temperature Accuracy Up to ±0.5 ℃
Heating Lid Heating Time Up to 10 min (from 25 ℃ to 100 ℃)
Multi-point Running Yes (max 5 points)
Multi Cycle Yes (max 99 times)
Storage at 4 ℃ Yes
Auto Running Yes
Auto Resume To Run Yes
Auto Heating Yes
Power Requirements AC 220 V or AC 100 V/ 50 to 60 Hz, 150 W
Fuse 250 V 3A Ф5 × 20
Dimensions 300 × 200 × 210 mm
Net Weight 4.7 Kg

Features

display

Semiconductor-controlled technology

Automatic temperature regulation

Extended timing range

Adjustable heating lid

FAQs

1. How does the Heated Lid Dry Bath Incubator ensure efficient and high-precision incubation?

Heated Lid Dry Bath Incubator Series Dry Bath Incubator ensures ultra-precise temperature control with its advanced semiconductor heating and cooling functions. It is equipped with high-speed thermal feedback and independent block temperature sensors, ensuring that each sample experiences uniform and accurate incubation. The adjustable heating lid not only prevents evaporation but also maintains a stable microenvironment, especially important for and enzymatic reactions. Moreover, it offers better cooling performance, supporting low-temperature protocols down to -10?°C. This makes it ideal for both high-sensitivity reactions and complex thermal cycling applications.

2. What automatic features enhance usability in the Heated Lid Dry Bath Incubator ?

Heated Lid Dry Bath Incubator introduces advanced automatic features such as auto-start, auto-heating/cooling, and auto-resume after power interruption. It also supports multi-point temperature programming (up to 5 points) and multi-cycle operation up to 99 cycles, allowing full automation of complex protocols. The inclusion of automatic lid heating control adds another layer of temperature stability. Real-time information is displayed through an interactive interface, giving users a clear and customizable experience. These intelligent features minimize manual oversight and improve overall lab efficiency.

3. What safety features are included in the Heated Lid Dry Bath Incubator ?

Heated Lid Dry Bath Incubator emphasizes safety with built-in over-temperature protection, auto-restart after power failure, and fault alarms. It provides independent block temperature monitoring to detect abnormalities early and prevent damage to samples. The incubator’s cooling and heating elements are isolated to avoid thermal interference, further ensuring safe operation. The adjustable lid also prevents sample loss due to evaporation, reducing contamination risk. Altogether, this Incubator ensures secure, worry-free operation for sensitive and long-duration procedures.

4. Can long-duration experiments be scheduled on the Heated Lid Dry Bath Incubator ?

Yes, the Heated Lid Dry Bath Incubator supports extended timing operations from 1 second up to 99 hours and 59 minutes, ideal for both rapid and long-term protocols. Whether you're running a short denaturation step or an overnight enzyme reaction, this incubator delivers consistent performance throughout. It supports multi-step programs with programmable timing and temperature changes at each stage. This flexibility is particularly useful for researchers working on sequential or staged incubations. Combined with its robust temperature control, it ensures precision for every experiment over any duration.

5. What built-in features make the Heated Lid Dry Bath Incubator distinct from others?

The Heated Lid Dry Bath Incubator offers a range of enhanced features, such as programmable multi-point temperature control, multi-cycle operations, and cooling capability down to -10?°C. It includes a heated lid with independent control, customizable blocks, and a compact design that fits crowded lab benches without compromising function. Real-time display, auto-resume, and safety alerts add to its intelligent operation. Each block is embedded with its own thermoelectric module, ensuring individual precision for multiple simultaneous experiments. These innovations make it a superior solution for labs requiring high performance and flexibility.

6. What cooling capabilities does the Heated Lid Dry Bath Incubator offer?

One of the standout features of the Heated Lid Dry Bath Incubator is its advanced semiconductor-based cooling function, which enables temperature control from as low as -10?°C to 100?°C. Unlike traditional models that offer only heating, the incubator supports precise active cooling, making it suitable for temperature-sensitive protocols such as cold enzyme reactions or pre- cooling. Each block in the unit operates with an independent cooling module, ensuring consistent and uniform cooling across all samples. It responds rapidly to temperature shifts, reducing waiting time between cycles or programs. This built-in cooling capability greatly expands its usability across molecular biology, clinical diagnostics, and other temperature-critical applications.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.