Introduction
Benchtop Dissolved Oxygen Meter measures dissolved oxygen from 0.00 to 20 mg/L. It supports temperature compensation from 0 to 100°C, ensuring accuracy under varying thermal conditions. Salinity compensation ranges from 0.0 to 50.0 g/L for versatile sample analysis. It includes a responsive electrode, touchscreen display, and intelligent functions like data storage and self-diagnostics. Suitable for water analysis in environmental labs, aquaculture, and wastewater treatment facilities.
This dissolved oxygen meter is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Benchtop Dissolved Oxygen Meter is ideal for water quality testing in environmental monitoring labs. It supports reliable DO measurements in aquaculture, wastewater management, and scientific research settings.
Specifications
| Dissolved Oxygen Range | 0.00 to 20 mg/L |
| Dissolved Oxygen Resolution | 0.01 / 0.1 |
| Dissolved Oxygen Accuracy | ±0.4 mg/L, ±0.3% |
| Dissolved Oxygen Saturation Range | 0.0 to 200% |
| Dissolved Oxygen Saturation Resolution | 0.1% |
| Dissolved Oxygen Saturation Accuracy | ±2.0% FS |
| Temperature Range | -10 to 110°C |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ±0.1°C |
| Temperature Compensation Range | 0 to 100°C (auto) |
| Salinity Compensation Range | 0.0 to 50.0 g/L |
| Air Pressure Compensation Range | 80 to 105 kPa (auto) |
| Air Pressure Resolution | 1 |
| Air Pressure Accuracy | ±2% |
| Stability | ±0.07 mg/L per hour |
| Response Time | ≤30 seconds at 25°C, 90% response |
| Display | 7-inch capacitive touch screen |
| Data Storage | 1000 sets |
| Communication Interfaces | , Bluetooth |
| Working Temperature | 5 to 40°C |
| Working Humidity | 5 to 85% |
| Power Requirements | 12V 1A (with adapter) |
| Dimensions | 240 × 170 × 70 mm |
| Net Weight | 0.8 kg |
Features
7-inch capacitive touchscreen
Bluetooth wireless printing
Real-time Android data transfer
Clock and function setup
IP54-rated waterproof design
Adjustable screen brightness
data export
Large internal memory
FAQs
1. What is the application of the Benchtop Dissolved Oxygen Meter in environmental labs?
The Benchtop Dissolved Oxygen Meter is ideal for measuring oxygen levels in water samples, which is essential for assessing water quality in environmental labs. It helps in monitoring the health of aquatic ecosystems by detecting dissolved oxygen levels. The meter provides highly accurate measurements even in challenging environments. This makes it invaluable for precise environmental monitoring and water quality analysis.
2. How does the temperature compensation feature work in the Benchtop Dissolved Oxygen Meter?
Benchtop Dissolved Oxygen Meter automatically compensates for temperature variations from 0 to 100°C, ensuring accurate dissolved oxygen readings regardless of thermal fluctuations. This feature is critical when testing water samples that experience temperature changes. By adjusting readings in real-time, it ensures optimal reliability. This makes the meter highly effective in diverse environmental conditions.
3. What is the maximum salinity compensation supported by the Benchtop Dissolved Oxygen Meter?
The Benchtop Dissolved Oxygen Meter offers salinity compensation from 0.0 to 50.0 g/L, allowing for accurate dissolved oxygen readings even in saline environments. This feature is particularly beneficial for marine research, aquaculture, and other water testing in coastal areas. The ability to adjust for salinity ensures the meter’s versatility and reliability across various water samples. This makes it ideal for diverse testing scenarios.
4. What maintenance is required for the Benchtop Dissolved Oxygen Meter to ensure long-lasting performance?
The Benchtop Dissolved Oxygen Meter requires minimal maintenance to keep it functioning effectively. Regularly clean the probe to prevent contamination, and calibrate the device periodically for accurate measurements. It’s also important to store the meter in a dry, cool place when not in use. These simple maintenance steps help prolong the life of the meter and maintain its performance.
5. How reliable is the Laboratory Bench Dissolved Oxygen Meter for use in environments with water exposure or dust?
Laboratory Bench Dissolved Oxygen Meter is built with an IP54-rated enclosure to ensure safe and consistent performance in environments where moisture and dust are present. This level of protection guards the internal components against limited dust ingress and splashing water, making it highly suitable for applications such as aquaculture, wastewater analysis, and environmental field monitoring. Although it is not designed for full water immersion, the IP54 rating enhances its durability when used on lab benches or semi-industrial workstations with humid or wet conditions.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.