Introduction

Thermal Shock Chamber is a two-zone chamber with a 42 range of +60 to +200°C for accurate heat exposure. The low-temperature range extends from 0 to -70°C, enabling rapid cooling simulations. Designed with a programmable controller and a color touch screen, it allows precise test control.  Suitable for evaluating material durability under extreme temperature variations in research and industrial applications.

This test equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Thermal Shock Chamber is designed for material stress testing, ensuring the reliability of electronic components and industrial products. It is widely used in aerospace, automotive, and semiconductor industries to simulate extreme temperature shifts.

Specifications

Capacity 42 L
High-Temperature Shock Range +60 to +200℃
Low-Temperature Shock Range 0 to -70℃
Hot Zone +60 to +200℃
Preheating Upper Limit 200℃
Heating Time R.T to +200℃ in 40 min
Cold Zone 0 to -70℃
Precooling Lower Limit -75℃
Cooling Time R.T to -70℃ in 60 min
Basket Temperature Range -65 to +150℃
Temperature Fluctuation less than or equal to 1℃
Temperature Deviation ±2℃ (-65℃ to +150℃)
Conversion Time less than or equal to 15s
Temperature Recovery Time less than or equal to 5 min
Shell Material Cold rolled sheet steel, spray plastics on surface
Internal Material SUS304 Stainless Steel
Thermal Insulation Material Glass wool or polyurethane foam
Refrigeration Mode Mechanical compression, two-stage refrigeration
Cooling Mode Air cooling/ water cooling
Controller Programmable controller, color touch screen
Communication Interface RS485, or interface (Optional)
Temperature Sensor Pt100
Power Supply AC380V±10%, 50±1Hz, three-phase four-wire + earth wire, ground resistance less than or equal to 4Ω
Basket Dimensions (D×W×H) 700×200×300 mm
External Dimensions (D×W×H) 2223×1125×2030 mm
Weight 1060 kg

Features

Stainless steel internal chamber

Glass wool insulation

Two-stage refrigeration system

Multiple communication interfaces

Two-zone thermal shock testing

Programmable temperature control

High-precision Pt100 sensor

FAQs

1. What are the key factors to consider when selecting this test equipment for laboratory use?

When selecting this test equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this test equipment be calibrated to ensure accurate results?

It is recommended to calibrate this test equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this test equipment?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this test equipment be used with different types of samples, and are there any compatibility considerations?

Yes, this test equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the test equipment malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.