Introduction

Microwave Digestion System operates at working temperature from 0 to 40°C ensuring optimal performance and reliability. Includes specialized, high-pressure (Teflon) digestion vessels to withstand aggressive acids and safely processing various sample types. Equipped with advanced thermal and pressure control for accurate digestion results. Offers an easy-to-use touchscreen interface for effortless method programming and monitoring. Built-in safety features ensure secure operation, preventing any overpressure or overheating incidents.

This microwave digestion system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Our Microwave Digestion System ensures precise sample preparation for Food, Feeds, Fertilizers, Water, Wastewater, Soil, Sludge, Filters, Pharmaceuticals, Vitamins, and Edible Oils, enhancing analytical accuracy.

Specifications

Microwave Source 2450MHz, Dual magnetron, high-energy emission
Microwave Cavity 65L, 316L stainless steel with multi-layer Teflon coating
Temperature Control Dual ZG system, real-time temperature detection, and curve display for all tanks
Pressure Control G-pressure monitoring automatic overpressure adjustment and alarm (range: 0 to 2000psig)
Pressure Measurement Piezoelectric pressure sensor
0 to 20M Pa (2500 psi)
Pressure Display Accuracy ±0.1M Pa
Temperature Measurement Optical fiber sensor
-50 to 320°C
Temperature Control Accuracy ±0.1°C
Temperature Display Accuracy ±1°C
Full Tank Temperature ZG infrared detection
0 to 320°C
Control Accuracy ±0.1°C
External Interface ,
Sample Reaction Outer Tank Aerospace composite fiber, explosion-proof
Furnace Exhaust System High-power axial flow fan, turbulent high-efficiency air cooling, 15 minutes from 200°C to 60°C
Working Environment 0 to 40°C, 15 to 80% RH
Batch Volume 40
Magnetic Stirring
Inner Tank Material
Outer Tank Material Explosion proof G-Fiber
Rotor Frame High-strength alloy turntable integrated frame
Reaction Tank Volume 10ml, 30ml, 55ml, 100ml
Maximum Pressure 16M Pa
Maximum Temperature 310°C
Display Screen Large 7-inch touch display
Software System chip, operating system, 3-level user management, audit trail
Power Consumption 3200W
Microwave: 2200W
Power Supply 220-240 50/60Hz 15A
Dimension 580mm×680mm×720mm
Packaging Dimension 660mm×690mm×1000mm
Net Weight 65kg
Gross Weight 70kg

Features

Built-in method library

Self-contained control screen

Stainless steel construction

Contactless temperature sensors

Exhaust and cooling system

Continuous cavity monitoring

Magnetron event detection

Automatic pressure relief

Internal video camera for tank monitoring

Eight-layer steel, self-ejection explosion-proof design

FAQs

1. What are the key factors to consider when selecting this microwave digestion system for laboratory use?

When selecting this microwave digestion system, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this microwave digestion system be calibrated to ensure accurate results?

It is recommended to calibrate this microwave digestion system at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this microwave digestion system?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this microwave digestion system be used with different types of samples, and are there any compatibility considerations?

Yes, this microwave digestion system can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the microwave digestion system malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.