Introduction

High Speed Centrifuge operates at a high-speed range of 500 to 15,000 rpm for efficient sample separation. It includes adjustable timer settings from 1 second to 99 minutes for versatile use. With acceleration and deceleration rates of ≤ 30 ± 5 seconds and 60 ± 5 seconds, it optimizes performance. Its compact design is suitable for various laboratory applications, complemented by a unique air duct that minimizes sample temperature rise. Our centrifuge is perfect for precise separation and temperature-sensitive sample handling in pharmaceutical labs and educational environments. It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.

Applications

Our Mini Centrifuge ensures rapid and precise sample separation with reliable performance and user-friendly operation. Its compact design makes it an excellent choice for clinical analysis, biological research, and quality assurance in various laboratory settings.

Specifications

Speed 500 to 15000rpm (100rpm increments)
Max. 100 to 15000×g (100×g increments)
Capacity 12 × 1.5/2.0ml
Timer 1s to 99m59s
Max. Rotor Radius 60mm
Soft Brake Function Yes
Liquid Temperature Rise ≤ 10℃
Noise Level ≤ 60dB
Acceleration/Deceleration Rate (Fast) Yes
Acceleration/Deceleration Rate (Slow) ≤ 30±5s
Max. Sample Density 60±5s
Voltage 1.2g/ml
Power DC24V 5A
Dimension 100W

Features

Whisper-Quiet Operation ≤ 60 dB

Gentle Brake Preserves sample integrity

Sterilizable durable aluminum alloy rotor

Quick button for instant centrifugation

Electronic Lock Prevents accidental openings

Automatic imbalance detection for safety

FAQs

1. What is the maximum sample volume that can be processed in the centrifuge?

The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.

2. How to balance the centrifuge before operation?

Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.

3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?

RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.

4. How to maintain the centrifuge to ensure long service life?

Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.

5. What safety precautions should be taken when using the centrifuge?

Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.