Introduction
Microwave Digestion System has a fully enclosed high-pressure digestion technology for improved recovery rates. Outer vessel is made of high-strength aerospace composite fiber. It provides both mechanical strength and anti-corrosion ability. The system has a safety bolt design for quantitative and safe pressure relief. Optical fiber and IR temperature measurement system ensures precise temperature regulation.
This microwave digestion system is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Microwave Digestion System is ideal for heavy metal analysis, organic pollutant extraction, and material synthesis across industries such as environmental testing laboratories, pharmaceutical research, chemical analysis, material synthesis, and quality control laboratories.
Specifications
| Vessel Quantity | 6 (Batch capacity can extend up to 8 vessels) |
| Temperature Monitoring System | Full vessel IR temperature control system |
| Working conditions | 0 to 40 °C, 15 to 80% RH |
| Temperature Controlling Range | - 40 to 305 °C |
| Temperature Accuracy | ± 0.1 ℃ |
| Pressure Monitoring System | High-precision semiconductor pressure sensor |
| Pressure Controlling Range | 0 to 15 MPa |
| Pressure Accuracy | ±0.01 MPa |
| Vessel Volume | 100 ml |
| Designed temperature of vessel | 300 °C |
| Designed pressure of vessel | 15 MPa |
| Sample Vessel Material | Imported |
| Protection Vessel Material | Aerospace composite fiber |
| Rotor frame type | Single frame type |
| Display | 7-inch Touch Screen |
| Microwave Tank | 316 L stainless steel tank with multi-layer corrosion-resistant Teflon |
| Air Exhaust | High-power corrosion-resistant turbo fan |
| Passive protection system | real-time abnormality monitoring system |
| Communication | and internet |
| Power supply | AC 220V to 240 , 50/60 Hz 20 A |
| Maximum output power | 1000 W |
| Power | 1800 W |
| Dimension (W × D × H) | 480 × 560 × 575 mm |
| Weight | 45 kg |
Features
touchscreen displays digestion status
Real time display of technical parameters
Supports microwave digestion, extraction and synthesis
Can be equipped with organic solvent leakage sensor
Cloud service function guarantees unlimited data storage
High durability with better flexibility
FAQs
1. What are the key factors to consider when selecting this microwave digestion system for laboratory use?
When selecting this microwave digestion system, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this microwave digestion system be calibrated to ensure accurate results?
It is recommended to calibrate this microwave digestion system at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this microwave digestion system?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this microwave digestion system be used with different types of samples, and are there any compatibility considerations?
Yes, this microwave digestion system can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the microwave digestion system malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.