Introduction

Microscopic Camera is adopted with digital 16M/MN34120(C), 1/2.33 inch (6.18×4.66) color sensor having dimension of 1.335 µm to 1.335 µm, 16 MP resolution, used to improve low light performance and obtain high resolution images. The exposure period of the sample to camera is 0.2 ms to 2000 ms and the 3.0 digital camera data interface is used with the spectral range of 380 to 650 nm with IR-filter to improve the quality of the image. This microscope is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Microscopic Camera used for high precision image analysis of low light, bright field, dark field, fluorescence in life science and industrial applications and so on.

Specifications

Sensor Model 16M/MN34120(C), 1/2.33 inch (6.18×4.66) color sensor
Sensor Dimension 1.335×1.335 µm pixels
Resolution 16 MP
G Sensitivity Dynamic Range SN Ratio R: 2453LSB Gr: 2444LSB Gb: 1054LSB B: 996LSB
Frame Rate 6.0 fps @4632×3488 15.0 fps @2320×1740 26.0 fps @1536×1160
Binning 1×1,2×2,3×3
Exposure 0.2 ms to 2000 ms
Data Interface 3.0
Spectral Range 380 to 650 nm (with IR Cut-filter)
White Balance White Balance / Manual Temperature-Tint Adjustment/ NA for Monochromatic Sensor
Color Rendering Technique Ultra Fine Color Engine/ NA for Monochromatic Sensor
Capture / Control Windows/Linux/macOS/Android Multiple Platform (Native C/C++, C#/VB., Python, Java, DirectShow, Twain, etc.)
Recording System Still Picture and Movie
Cooling System Natural
Operating Environment
Operating Temperature -10 to 50°C
Storage Temperature -20 to 60°C
Operating Humidity 30 to 80 % RH
Storage Humidity 10 to 60 % RH
Power Supply DC 5V over PC Port
Software Environment
Operating System Microsoft® Windows® XP / Vista / 7 / 8 /10 (32 & 64 bit) OSx(Mac OS X) Linux
PC Requirement : Equal to Intel Core 2 2.8 GHz or Higher, Memory:2 GB or More, Port:USB3.0 High-speed Port, Display:17inches or Larger, CD-

Features

Sensor Model: 16M/MN34120(C), 1/2.33 inch (6.18×4.66) color sensor

Adopted ultra-high performance sensor as the image-picking device

White Balance / Manual Temperature-Tint Adjustment

Ultra Fine Color Engine technique

3.0 Digital Camera data interface

aluminium alloy housing

With advanced video & image processing application ToupView

Providing Windows/Linux/Mac OS multiple platforms

Spectral Range: 380 to 650 nm with IR Cut-filter

Exposure period of sample is 0.2 ms to 2000 ms

Natural cooling system

FAQs

1. What are the key factors to consider when selecting this microscope for laboratory use?

When selecting this microscope, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.

2. How often should this microscope be calibrated to ensure accurate results?

It is recommended to calibrate this microscope at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.

3. What are the common maintenance procedures required for this microscope?

Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.

4. Can this microscope be used with different types of samples, and are there any compatibility considerations?

Yes, this microscope can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.

5. What should be done if the microscope malfunctions or produces inconsistent results?

If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.