Introduction

is an advanced floor standing high speed refrigerated centrifuge. It is an efficient, safe and reliable instrument that provides high-throughput sample processing. With its wide acceleration and deceleration range, protection device, it offers exceptional performance satisfying the emerging medical and research laboratory applications.

It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.

Applications

It finds wide application in food processing industries, cell culture and cell separation in biopharmaceutical/ biotech industries. It is also used in blood banks and research and clinical laboratories.

Specifications

Max. Speed 22,000 rpm
Max. 57,358 x g
Max. Capacity 4 x 1000 ml
Temp. Range -10°C to 40°C
Acceleration/ Deceleration profiles 10
Timer Range 99 hrs. 59 min. 59 sec.
Power Supply 220 V / 60 Hz
Dimension (H x W x D) 668.7 x 800.6 x 891.3 mm
Net Weight 230 kg

Features

display

Wide acceleration and deceleration range

Advanced microprocessor-chip ensuring superior performance

Automatic / conversion

Extensive choice of versatile rotors

Easy user interface

Automatic rotor identification and imbalance shut off to protect each rotor and sample from unsafe operating speeds

Noise less operation

High torque drive system by AC induction motor

Less turnaround time

Program memory can store up to 100 programs

Reliable in use

FAQs

1. What is the maximum sample volume that can be processed in the centrifuge?

The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.

2. How to balance the centrifuge before operation?

Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.

3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?

RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.

4. How to maintain the centrifuge to ensure long service life?

Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.

5. What safety precautions should be taken when using the centrifuge?

Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.