Introduction
Automatic Film Processor offers 5-roll capacity for fast and precise development of industrial X-ray and films. It provides automatic film detection for efficient processing in high-demand workflows. Integrated temperature control ensures stable chemical performance for consistent results. Built-in non-contact feeding protects films during transport for smooth operation. Our Automatic Film Processor ensures reliable film handling for accurate development used in industrial inspection environments.
This test equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Automatic Film Processor is used for developing and X-ray films in testing workflows where precise, consistent film processing is required.
Specifications
| Roll Film Capacity | Processes Up to 5 Rolls Simultaneously |
| Processing Speed | 4 to12 Minutes ( cycle time) |
| Optimal Processing Time | 8 Minutes Per Batch |
| Processing Capacity | 240 Sheets / Hour (80 × 360 mm) |
| Developing Temperature | Adjustable from 24 to 36 °C |
| Water Consumption | Approximately 3 L / min |
| Minimum Film Size | 60 × 100 mm |
| Maximum Film Size | 432 mm width × unlimited length |
| Roll Film Width | Compatible with 60 to 100 mm rolls |
| Film Feeding System | Photoelectric Induction Mechanism |
| Automatic Film Detection | Detects Film Entry Automatically |
| Feeding Type | Non-Contact, Scratch-Free Film Feeding |
| Developer Tank Capacity | 16 Liters |
| Fixer Tank Capacity | 16 Liters |
| Washing Tank Capacity | 16 Liters |
| Chemical Replenishment | Automatic Replenishment System |
| Construction | Corrosion- and Heat-Resistant Build |
| Standby Mode | Energy-Saving Automatic Standby |
| Power Consumption | Less than 2.5 kW |
| Power Supply | AC 220 V, 50 / 60 Hz |
| Dimensions | 1300 × 840 × 1320 mm |
| Net Weight | 125 kg |
| Gross Weight | 150 kg |
Features
Stable film transport
Automatic film detection
Non-contact feeding
Corrosion-resistant construction
FAQs
1. What are the key factors to consider when selecting this test equipment for laboratory use?
When selecting this test equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this test equipment be calibrated to ensure accurate results?
It is recommended to calibrate this test equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this test equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this test equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this test equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the test equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.