Introduction
Gas Chromatography operates reliably between room temperature +15 °C and 399 °C. Microprocessor-based control circuit with large memory ensures reliable and secure data storage. Automated gas extraction and injection reduce manual handling, ensuring consistent analytical performance. Efficiently separates dissolved gases from transformer oil samples using vacuum or headspace techniques. Ideal for fault diagnosis in power transformers, insulation quality monitoring and quality assurance of transformers and oils.
This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Gas Chromatography functions as a transformer oil dissolved gas chromatograph for fault diagnosis in power transformers, insulation quality monitoring, life assessment of transformer assets and quality assurance of transformers and oils.
Specifications
| Column chamber temperature range | Room temperature +15°C to 399°C |
| Conversion furnace temperature range | Room temperature +30°C to 399°C |
| Thermal conductivity detector temperature range | Room temperature +30°C to 399°C |
| Thermal conductivity noise | Less than or equal to 0.05mv |
| Thermal conductivity drift | Less than or equal to 0.15mv/30min |
| Hydrogen flame detector temperature range | Room temperature +30°C to 399°C |
| Hydrogen flame detector noise | Less than or equal to 0.05mv |
| Hydrogen flame detector drift | Less than or equal to 0.15mv/30min |
| Minimum detectable concentration of hydrocarbon | Less than or equal to 5μl/L |
| Temperature control precision | ±0.1°C |
| Machine start-up time | Less than 3 hours |
| Program heating rate | 0.1ºC to 40ºC |
| Constant temperature holding time of each stage | 0.1 to 9999.9min |
| Power consumption | 2kW |
| Power supply | AC 220V±10% 50HZ |
| Column temperature box volume | 260mm × 260mm × 248mm |
| External dimension | 660mm × 460mm × 465mm |
| Packaging dimension | 700mm × 500mm × 500mm |
| Net Wight | 55 kg |
| Gross weight | 58kg |
Features
Multi-Gas Detection Capability
Flame Ionization Detectors
Rapid Analysis Time
High-Precision Thermal Conductivity
Temperature-Stable Chromatography Oven
FAQs
1. What are the key factors to consider when selecting this analytical equipment for laboratory use?
When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this analytical equipment be calibrated to ensure accurate results?
It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this analytical equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the analytical equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.