Introduction
Heated features a block temperature setting range of -10℃ to 100℃ for versatile thermal applications. The high-definition 5-inch full-touch screen enables quick protocol editing and real-time display of temperature curves and status. It offers dual-mode hot lid temperature control for independent or relative temperature settings. Our Dry Bath Incubator is ideal for temperature control in molecular and clinical lab procedures.
It provides a stable and controlled environment for cell culture, microbial growth, and other biological experiments. The precise temperature and humidity control ensure consistent experimental conditions and reliable results.Applications
Heated Lid Dry Bath Incubator is designed for precise temperature control in molecular biology, clinical diagnostics, and biochemical research. It is ideal for applications like , , nucleic acid denaturation, enzyme reactions, and sample preservation.
Specifications
| Block Temperature Setting Range | - 10℃ to 100℃ |
| Block Temperature Control Range | (R.T.-25℃) to 100℃ |
| Temperature Maximum Decrease | R.T. decreases 25℃ at R.T. 26℃ |
| Hot Lid Temperature Setting Range | 0 to 105℃ / Block+(0 to 105℃) |
| Hot Lid Temperature Control Range | R.T.+5℃ to 105℃ |
| Time Range | 1s to 99m59S / 0 is infinite |
| Maximum Number of Steps | 10 |
| Maximum Number of Cycles | 99 |
| Block Temperature Control Accuracy | ±0.5℃ |
| Hot Lid Temperature Accuracy | ±1.0℃ |
| Block Temperature Uniformity | ±0.5℃ |
| Display Accuracy | 0.1℃ |
| Heating Time (R.T.25℃) | 37℃ to 100℃ greater than or equal to 7℃/min |
| Cooling Time | 100℃ to 37℃ greater than or equal to 8℃/min |
| Dimensions (W×D×H) | 185 × 280 × 160 mm |
| Weight | 3.2 kg |
Features
10 programmable memory groups
High temperature control accuracy
Supports infinite time hold
Built-in refrigeration capability
Automatic lid height adaptation
FAQs
1. What safety features are included in the Heated Lid Dry Bath Incubator for lab use?
Heated Lid Dry Bath Incubator is equipped with several safety features to ensure reliable operation. It uses low-voltage semiconductor technology, which reduces electrical risk. The device includes an elastic heated lid that applies gentle pressure, preventing spills or lid overheating. Built-in sensors ensure thermal cut-off in case of over-temperature conditions. Additionally, real-time monitoring on the display helps detect anomalies. The chemically resistant body protects against common lab spills. These features make it safe for continuous and unattended use in labs.
2. Can the Heated Lid Dry Bath Incubator operate continuously for long-term reactions?
Yes, the Heated Lid Dry Bath Incubator supports continuous operation through its time setting feature. Users can set the timer to "0" to enable infinite run mode, which is ideal for extended reactions or overnight incubations. This is particularly useful for enzyme kinetics, long reactions, or sample preservation tasks. The incubator maintains a precise and stable temperature throughout, ensuring no deviation over time. Its durable build and cooling system allow it to operate safely for prolonged periods.
3. How is the Heated Lid Dry Bath Incubator different from a traditional dry bath incubator?
Heated Lid Dry Bath Incubator offers advanced features that set it apart from traditional dry baths. It includes a heated lid that prevents condensation and enhances reaction efficiency, especially in molecular assays. Unlike basic models, it has programmable multi-step cycles, real-time temperature graphs, and a touch-screen interface. Its cooling capability down to -10°C and dual-mode lid settings offer flexibility for various workflows. These features make it more versatile for research, diagnostics, and advanced testing applications.
4. What types of tubes or vessels are compatible with the Heated Lid Dry Bath Incubator ?
Designed for versatility, the Heated Lid Dry Bath Incubator supports a wide range of vessels through its interchangeable block system. It accommodates microcentrifuge tubes (0.2 mL, 0.5 mL, 1.5 mL, 2.0 mL), tubes, strip tubes, and other specialized lab formats. Users can easily choose and install blocks tailored to their specific needs, with tool-free block exchange enhancing convenience. This flexibility makes the incubator suitable for diverse protocols in molecular biology, biochemistry, and clinical laboratory workflows. The precise fit of each block ensures uniform heat distribution across all samples. Its compact, modular design also makes it easy to transport and reconfigure for different experimental setups.
5. Does the Heated Lid Dry Bath Incubator provide visual feedback for monitoring experiments?
Yes, the Heated Lid Dry Bath Incubator is equipped with a 5-inch full-colour touchscreen that provides real-time visual feedback. The screen displays the temperature curve, step progress, and operating mode. Users can track heating, holding, or cooling phases at a glance. It also shows lid temperature, remaining time, and cycle count. This live visual interface makes it easy to monitor experiments without interrupting the incubation process, helping ensure better control and reproducibility.
6. What is the heating and cooling performance of the Heated Lid Dry Bath Incubator ?
Heated Lid Dry Bath Incubator is engineered for rapid temperature changes to enhance lab efficiency. It can heat from 37°C to 100°C at a rate of ?7°C per minute and cool from 100°C to 37°C at a rate of ?8°C per minute. This fast performance is powered by semiconductor technology and controlled by a algorithm. Such rapid transitions are ideal for labs needing quick turnaround in protocols like enzyme reactions, denaturation, or thermal cycling. The consistent ramp rates help reduce total protocol time while maintaining temperature accuracy. This makes it a valuable tool for time-sensitive and high-throughput laboratory workflows.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.