Introduction
Temperature and Humidity Test Chamber features a user-friendly 7-inch touchscreen controller for easy operation. It offers efficient drainage that guides water smoothly through the drainage port. A high-efficiency fan with a stainless-steel shaft is powered by an externally mounted motor. It includes a long-axis induction motor with low voltage and high-temperature resistance. Our chamber is ideal for electronics, automotive, aerospace, and renewable energy testing.
This test equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our chamber is ideal for testing electronics, automotive components, aerospace materials, and renewable energy equipment, ensuring reliable performance under controlled temperature and humidity conditions across various industrial applications.
Specifications
| Capacity | 225 L |
| Temperature Range | - 40 ℃ to + 150 ℃ (Optional + 180 ℃) |
| Temperature Uniformity | ± 2.0 °C |
| Temperature Fluctuation | ± 0.5 ℃ |
| Temperature Deviation | ± 2.0℃ |
| Temperature Resolution | + 0.1 ℃ |
| Heating Rate | - 40 ℃ to + 100 ℃ |
| Cooling Rate | + 20 ℃ to – 40 ℃ |
| Humidity Range | 20 % to 98 % R.H |
| Humidity Uniformity | ± 3 % R.H |
| Humidity Fluctuation | ± 2.0 % R.H |
| Humidity Deviation | ±3.0 % / 5.0 % R.H |
| Humidity Resolution | + 0.1 % |
| Ambient Temperature | 5 °C to 35 °C |
| Humidifier Type | Stainless-steel electric heating humidifier |
| Compressor | Copeland or Tecumseh or Sanyo compressor |
| Controller | 7-inch touch screen controller |
| Centrifugal Blower | Multi-wings centrifugal blowers with aluminum alloy blades |
| Display Type | 7-inch touch screen |
| Communication Interface | , , and (Optional) |
| Evaporator | High efficiency multi-stage fin type evaporator |
| Refrigeration System | Single stage refrigeration system with R404A refrigerant |
| Drainage Port | φ10 mm soft silicone drain pipe |
| Noise | ≦ 75 (dB) |
| Exterior Chamber Material | High-quality carbon steel with painting |
| Interior Chamber Material | SUS304 matte stainless-steel plate |
| Insulation Material | Rigid polyurethane foam insulation, flame retardant grade B2 |
| Power Consumption | 5 KW |
| Power supply | AC 380V ±10% 50Hz / AC 220V ±10% 50Hz |
| Internal Dimensions | 700 × 700 × 480 mm |
| External Dimensions | 900 × 1735 × 1505 mm |
| Package Dimensions | 1110 × 2100 × 1750 mm |
| Net Weight | 430 Kg |
| Gross Weight | 580 Kg |
Features
Dual Stage Air Circulation Fans
Touch Lock Screen Protection
Anti-Vibration Construction
Wide Operating Range
Uniform Temperature Distribution
FAQs
1. What types of products can be tested in a Temperature And Humidity Test Chamber ?
A wide range of products from different industries can be tested using the Temperature And Humidity Test Chamber . These include electronic components, medical devices, automotive parts, plastics, and textiles. It is also commonly used for testing batteries, solar panels, and aerospace materials. Any product that may be affected by environmental changes is suitable for such testing. The chamber helps determine how materials react to prolonged exposure to heat, cold, and moisture. This information is crucial for design optimization and regulatory certification. It ensures the product performs reliably under the conditions it will face during storage, shipping, or usage.
2. How is humidity generated and regulated in the Temperature And Humidity Test Chamber ?
Humidity in the Temperature And Humidity Test Chamber is typically controlled using a water-based humidification system. This system either uses steam injection or an ultrasonic humidifier to add moisture into the air. Dehumidification occurs through cooling coils that condense moisture when lower humidity is required. The humidity levels are measured by precision sensors and managed by the controller. The chamber maintains a consistent relative humidity range to match testing needs. High-purity water is usually recommended to prevent scaling and ensure sensor longevity. This mechanism allows precise moisture control for sensitive testing protocols.
3. How does the Temperature And Humidity Test Chamber ensure safety during operation?
The Temperature And Humidity Test Chamber is equipped with several safety features to protect users and test samples. These include over-temperature and over-current protection systems that shut down the chamber if limits are exceeded. The chamber also features door interlocks to prevent opening during operation, avoiding injury and contamination. Automatic shutdown systems activate during power failure or system malfunction. Leak detection systems and circuit breakers add additional layers of safety. Built-in alarms notify operators of deviations or potential faults. These safety protocols ensure secure and uninterrupted testing operations.
4. Why is uniform airflow important in the Temperature And Humidity Test Chamber ?
Uniform airflow ensures that temperature and humidity are evenly distributed throughout the test space. Without it, certain areas of the chamber might experience hot or cold spots, which could lead to inconsistent test results. High-performance chambers include specially designed airflow circulation fans and duct systems to eliminate this issue. Even airflow is particularly critical for tests requiring strict environmental uniformity, such as in aerospace or pharmaceutical validation. Proper airflow helps maintain the accuracy of stress simulations across all sample positions. It also enhances the repeatability of results across multiple test cycles. This ensures that every specimen, regardless of placement, receives identical exposure conditions.
5. How does the Temperature And Humidity Test Chamber maintain stable environmental conditions over long test durations?
Temperature And Humidity Test Chamber is equipped with advanced control systems that use real-time feedback from precision sensors. These sensors constantly monitor internal conditions and send data to a programmable logic controller (). The automatically adjusts heating, cooling, humidification, or dehumidification functions to maintain target setpoints. High-quality insulation materials help reduce heat loss or gain from external sources. The use of (Proportional-Integral-Derivative) algorithms ensures fine-tuned corrections, avoiding sudden fluctuations. The internal airflow design ensures uniform distribution of temperature and humidity to every part of the chamber. This integrated system allows for extended-duration testing with high consistency and minimal deviation from the set parameters.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.