Introduction
Low Speed Centrifuge features a maximum speed of 5000 rpm with an accuracy of ± 10 rpm. It features a chamber made of 304 stainless steel that is resistant to corrosion, thereby enhancing the longevity of the centrifuge. The centrifuge is capable of operating for 24 blood tubes, each with a capacity of 10 mL. Its screen displays / and time for precise settings and a reliable operation. Our centrifuge is used in various clinical settings and laboratories for blood centrifugation processes.
It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.Applications
Our Low Speed Centrifuge is ideal for use in hospitals, test laboratories, blood banks, and diagnostic clinics. It is suitable for centrifugation of blood samples.
Specifications
| Max Speed | 4200 rpm |
| Speed Accuracy | ± 20 rpm |
| Max | 2680 × g |
| Capacity | 24 × 10 mL (Blood Tube) |
| Blood Tube Size | 13 mm and 16 mm |
| Display | |
| Timing Range | 1 min to 99 min |
| Noise | Up to 60 dB (A) |
| / Rates | 20 rates |
| Programs | Up to 100 |
| Power Consumption | 250 W |
| Dimension | 410 × 300 × 350 mm |
| Net Weight | 17 kg |
Features
Aluminum alloy fixed angle rotor
Parameter setting during operation
Timer function with adjustable timing range
Durable and sturdy structure
FAQs
1. What is the maximum sample volume that can be processed in the centrifuge?
The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.
2. How to balance the centrifuge before operation?
Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.
3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?
RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.
4. How to maintain the centrifuge to ensure long service life?
Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.
5. What safety precautions should be taken when using the centrifuge?
Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.
1. What makes the Low Speed Centrifuge particularly suitable for blood sample processing?
Low Speed Centrifuge is engineered specifically for blood separation applications. With its dedicated 24 × 10 mL tube capacity, it is ideal for clinical diagnostics, pathology labs, and blood banks. The rotor is optimized for 13 mm and 16 mm diameter blood tubes, ensuring proper balancing and consistent sedimentation of blood components like plasma, red cells, and buffy coat. This targeted configuration makes it a reliable tool for routine hematological workflows.
2. What role does the fixed-angle rotor play in the operation of the Low Speed Centrifuge ?
Low Speed Centrifuge includes a robust aluminum alloy fixed-angle rotor that enhances performance by providing a stable and even centrifugal force during rotation. Fixed-angle rotors are particularly effective for sedimentation because they direct particles to the bottom of the tube at a shallow angle, reducing sample disturbance. The aluminum alloy build not only provides excellent strength-to-weight ratio but also supports long-term durability and corrosion resistance.
3. How does the Low Speed Centrifuge help ensure user-friendly and accurate operation?
This Low Speed Centrifuge features an intuitive display that shows real-time values for (or ) and remaining time, making it easy for users to monitor each run precisely. The ability to adjust operational parameters during centrifugation provides flexibility in real-time lab scenarios, and the built-in timer allows runs from 1 to 99 minutes. This blend of convenience and precision is essential for minimizing human error in high-throughput or time-sensitive environments.
4. What safety and structural features contribute to the reliability of the Low Speed Centrifuge ?
Designed with daily clinical use in mind, our Low Speed Centrifuge features a corrosion-resistant 304 stainless-steel chamber that stands up to frequent cleaning and exposure to biological materials. Its compact, 17 kg structure ensures stability during operation and portability for mobile or space-constrained lab environments. Additionally, it operates quietly, reducing auditory fatigue and enabling placement in patient-facing or multi-device labs.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.