Introduction
Single Beam UV-Visible Spectrophotometer features a wavelength resolution of 0.1 nm for analyzing complex samples or subtle spectral shifts with high precision. The spectrophotometer has tungsten and deuterium lamps, ensuring complete spectral coverage. It includes holographic diffraction grating for uniform spectral efficiency across the wavelength range. Our single beam UV-visible spectrophotometer offers three adjustable scanning speeds to balance scan duration and data quality.
This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Single Beam UV-Visible Spectrophotometer passes monochromatic light through a sample to determine chemical characteristics. It is applied in biochemical analysis, environmental monitoring and pharmaceutical industries in quality control.
Specifications
| Spectral Bandwidth | 4nm (optional 2nm) |
| Wavelength Range | 320 to 1100 nm |
| Optical System | Single beam path, holographic diffraction grating |
| Wavelength Accuracy | ± 0.8 nm |
| Wavelength Repeatability | 0.2 nm or less |
| Wavelength Setting | Automatic Wavelength Setting |
| Wavelength Resolution | 0.1 nm |
| Luminosity Range | 0 to 200% T, -0.3 to 3A, 0 to 9999 C, 0 to 9999 F |
| Photometric Accuracy | ±0.002A (0 to 0.5A), ±0.004A (0.5 to1A), ±0.3%T (0 to100%T) |
| Photometric Repeatability | ≤ 0.001A (0 to 0.5A), ≤0.002A (0.5 to 1A), ≤0.2%T (0 to 100%T) |
| Stray Light | ≤0.1%T (220/360nm) |
| Baseline Drift | ≤0.002A/ h (500nm,0A) |
| Noise | ± 0.2%T (0%T line) ±0.4%T (100%T line) ±0.001A (500nm) |
| Baseline Flatness | ±0.003A |
| Scan Speed | Three adjustable speeds: high, medium and low |
| Detector | Imported silicon photodiode |
| Light Source | Imported long-life tungsten and deuterium lamps |
| Display | 3-inch 128× 64 dot matrix display |
| Keyboard | Tap film keys |
| Data Interface | Port |
| Printout | Microprinter, PC (Optional) |
| Power Supply | AC 902 to50V, 50/60Hz |
| Overall Dimensions | 430 ×320 ×195mm |
| Weight | 10 kg |
Features
Wide Wavelength Range
Standard Curve Display
Silicon Photodiode Sensors
Dual Lamp Sources
Adjustable Scan Speed
FAQs
1. How does the Single Beam UV-Visible Spectrophotometer F12 reduce stray light effects at high absorbance?
Single Beam UV-Visible Spectrophotometer F12 Single Beam UV-Visible Spectrophotometer minimizes stray light—unwanted wavelengths that can distort measurements at absorbance over ~2?AU—by using high-grade holographic gratings and tight optical seals, ensuring more accurate results in high-concentration assays. Its stray light performance is validated using cutoff filters like sodium nitrite or potassium chloride, and should meet or exceed pharmacopeial standards for dynamic range. Proper external checks and maintenance ensure this capability remains intact over its service life.
2. How does the Single Beam UV-Visible Spectrophotometer F12 maintain wavelength accuracy and resolution over time?
Single Beam UV-Visible Spectrophotometer incorporates automated wavelength calibration using certified standards like mercury or holmium filters, allowing users to self-verify and adjust peak positioning within ±0.1?nm accuracy. Its high-resolution holographic diffraction grating further ensures crisp spectral resolution so closely spaced peaks remain identifiable. Routine performance checks help catch minimal drift early, maintaining consistent analytical precision for critical quantitative applications.
3. How can I troubleshoot ghost peaks or spectral anomalies on the Single Beam UV-Visible Spectrophotometer F12?
Single Beam UV-Visible Spectrophotometer may occasionally display ghost peaks due to internal reflections or diffraction from mirrors, gratings, or particles within the optical path. To combat this, clean and inspect all optics, ensure the monochromator slits are free from debris, and verify that internal surfaces remain well-aligned. Regular stray-light tests using cutoff filters can expose specific sources of unwanted signals, enabling precise corrective action.
4. What causes non-linear Beer Lambert behavior in the Single Beam UV-Visible Spectrophotometer F12, and how to correct it?
It supplies advanced Single Beam UV-Visible Spectrophotometer , deviations from linear absorbance arise when sample absorbance exceeds ~1?AU due to stray light, saturation, or chemical interactions like aggregation or refractive index shifts. To maintain Beer Lambert compliance, dilute samples, use shorter pathlength cuvettes, filter turbid solutions, and validate linearity with calibration curves. These strategies preserve quantitation integrity across concentration ranges.
5. How does the F12 manage lamp-switch artifacts in UV–Vis scans?
Single Beam UV-Visible Spectrophotometer transitions between deuterium and tungsten lamps around 320–360?nm; this switch can introduce artifacts if not synchronized well. To reduce crossover noise, the system delays data acquisition during lamp transitions, employs precise lamp alignment routines, and allows users to adjust the switch threshold in software. Periodic maintenance ensures smooth lamp toggling and continuity of spectra across the UV–Vis boundary.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.