Introduction
Spectrometer is a compact benchtop design that offers a spectral bandwidth of 755 to 1100 nm. It has an SMA905 optical fiber interface for efficient light signal transmission. The linear silicon-based detectors ensure reliable and consistent data collection. Its customizable silt option that supports 10, 25, 50, 100 and 200 µm slit, offering excellent resolution for detailed spectral measurements. Our Spectrometer is widely used for phosphor detection, fabric measurement and biological measurement.
This analytical equipment is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.Applications
Our Spectrometer is widely used across a variety of scientific and industrial applications. It plays a vital role in light source color analysis, concentration measurement, color measurement and analysis, as well as fabric testing. It is extensively applied in phosphor detection, solar panel inspection, and biochemical process monitoring. Additionally, it is also ideal for light analysis, chemical analysis and identification, biological measurement, and serves as an effective tool for evaluating optical component transmittance and reflectance.
Specifications
| Wavelength Range of the Spectroscope | 755 to 1100 nm |
| Detector Type | Linear silicon-based detector |
| Detector Dynamic Pixel | 3648 |
| Light Source Size | 8 µm × 200 µm |
| Working Temperature | -20℃ to -60℃ |
| Slit | 200 µm (customizable) |
| Optical Resolution of the Spectroscope | 1.25 nm (different resolution for slits) |
| Spectral Splitter Fiber Optic Connector | SMA905 |
| Stray Light | Up to 0.1% |
| Correction of Linearity | 99.80% |
| Data Interface | 2.0 |
| A/D Conversion | 16-bit high-precision height AD |
| Power Consumption | 160 mA at 5V |
| Power Supply | Computer power supply or external 5V power supply |
Features
High-resolution optical platform
Shortest integration time
Fixed grating
Miniature design
FAQs
1. What are the key factors to consider when selecting this analytical equipment for laboratory use?
When selecting this analytical equipment, key factors include: 1) The instrument's precision and accuracy to meet experimental requirements; 2) Compatibility with the types of samples and applications you will be working with; 3) Ease of use and maintenance requirements; 4) Safety features to protect operators and samples; 5) Calibration and certification requirements; 6) Cost-effectiveness and long-term reliability; 7) Technical support and service availability from the supplier. Evaluating these factors ensures that the instrument meets your laboratory's specific needs.
2. How often should this analytical equipment be calibrated to ensure accurate results?
It is recommended to calibrate this analytical equipment at least once every 6-12 months under normal usage conditions. More frequent calibration (every 3-6 months) may be necessary if: 1) The instrument is used continuously for extended periods; 2) It is exposed to harsh environmental conditions (temperature fluctuations, humidity, dust); 3) It is used for critical applications requiring high precision; 4) The instrument has been moved or subjected to physical shock; 5) Calibration checks indicate significant deviations from standard values. Always follow the manufacturer's calibration guidelines.
3. What are the common maintenance procedures required for this analytical equipment?
Common maintenance procedures include: 1) Regular cleaning of the instrument's exterior and sample contact surfaces to prevent contamination and ensure proper operation; 2) Inspection of moving parts (if applicable) for wear and lubrication as recommended by the manufacturer; 3) Replacement of consumable parts (filters, bulbs, reagents) according to usage guidelines; 4) Verification of performance parameters (temperature, pressure, voltage) regularly; 5) Storage of the instrument in a clean, dry environment when not in use; 6) Keeping a maintenance log to track service activities and identify potential issues early; 7) Following the manufacturer's specific maintenance schedule for optimal performance and longevity.
4. Can this analytical equipment be used with different types of samples, and are there any compatibility considerations?
Yes, this analytical equipment can be used with a variety of sample types, but compatibility considerations are important: 1) Check if the instrument's materials are compatible with the chemical composition of your samples (avoid corrosive or reactive substances that may damage the instrument); 2) Ensure that the sample volume and concentration are within the instrument's recommended range; 3) For biological samples, consider sterility requirements and potential cross-contamination risks; 4) For volatile or hazardous samples, ensure proper ventilation and safety precautions are in place; 5) Consult the manufacturer's documentation for specific sample compatibility guidelines, and perform compatibility tests with new sample types before regular use.
5. What should be done if the analytical equipment malfunctions or produces inconsistent results?
If malfunctions or inconsistent results occur: 1) First, check the instrument's user manual for troubleshooting guidelines specific to the issue; 2) Verify that the instrument is properly calibrated and within its calibration period; 3) Inspect for obvious issues such as loose connections, damaged parts, or incorrect settings; 4) Clean the instrument thoroughly to remove any contamination that may affect results; 5) Repeat the experiment with a known standard sample to determine if the issue is with the instrument or the sample; 6) If the problem persists, discontinue use of the instrument to prevent further damage or inaccurate results; 7) Contact technical support or a qualified service technician for diagnosis and repair, providing details of the issue and any troubleshooting steps already performed.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.