Melting Point Apparatus offers a processing capacity of four-sample batches for simultaneous processing up to 4 capillary tube samples per run. The system has an integrated visual monitoring system, featuring high-resolution optics to precisely observe melting transitions. It is equipped with advanced a bright sample chamber illumination, ensuring visible observation of samples throughout the melting process. Our melting point apparatus is constructed from high-quality stainless steel and aluminum, delivering precise thermal conductivity.

This melting point apparatus is designed to meet the rigorous requirements of modern laboratory operations, ensuring high precision, reliability, and ease of use for various experimental applications.

Applications

Melting Point Apparatus observes the precise temperature range at which it transitions from solid to liquid. It is widely used in forensics, pharmaceuticals, and chemical industries for identifying unknown solids by comparing their melting behavior.

Specifications

Temperature Range RT to 350°C
Detection Method Fully automatic
Processing Capacity 4 / batch
Temperature Resolution 0.1°C
Warming Rate 0.1°C to 20°C
Temperature Control Mode temperature control furnace body fully sealed design
Heating Mode Conduction fluid heating or hot block air heating
Accuracy ± 0.3°C (< 200° C)
± 0.5°C (>200° C)
Repeatability ± 0.1°C at 0.1°C / Min
Video Function Take pictures and Videos
Video Playback Have a time watermark
Magnification 20
User Management >60
Data Storage 32 Hard Drive, 2GB Memory
Experimental Method Storage 300 sets
Display Mode 8’HD Color Screen
Data Interface , network wifi interface, RS 232
Standard Capillary Size Outer diameter 1.4mm, inner diameter 41.0 mm
Power Supply 110 to 220 V 50 Hz / 60 Hz
Power Consumption 120 W

Features

Capillary Tube Sample Holders

High-Precision Temperature Sensors

Automated Melt Detection

Optical / Magnification System

High- Speed Preheating Mode

FAQs

1. What are the most common causes of melting point errors and how can they be resolved in ?

It supplies advanced models of melting point apparatus . Misleading results often stem from sample impurities (which depress melting points), overly rapid heating (masking true melting behaviour), blocked light paths or dirty optical systems, or faulty temperature sensors. Troubleshooting involves inspecting and cleaning optics, verifying sensor calibration, replacing defective capillaries, and comparing sample readings with known references to isolate sample issues.

2. What environmental and operational precautions improve measurement consistency in ?

It supplies advanced models of melting point apparatus . To maintain instrument longevity and accuracy, keep the device in a dry, dust-free, and well-ventilated environment. Clean the sample holder and optical window before each run to prevent buildup. Use only approved capillaries and avoid inserting damaged or contaminated tubes. After use, power down and allow the block to cool safely before removing samples or cleaning, protecting both equipment and user.

3. How should samples be prepared to ensure accurate melting point results in melting point apparatus ?

It supplies advanced models of melting point apparatus . Effective sample preparation starts by grinding your substance to a fine, dry powder to achieve uniform particle size, ensuring consistent thermal behaviour. The powder should be carefully packed into a clean capillary tube, avoiding air gaps and external residue that could impact heat transfer or contaminate the instrument. Gently tapping the tube helps settle the sample at the bottom of the capillary, promoting precise melting transitions and reducing variability caused by uneven packing or moisture.

4. What are common causes of melting point discrepancies and how are they identified in melting point apparatus ?

It supplies premium melting point apparatus . Deviations from expected values may arise from impurities (which lower and broaden the range), overheating (from too-fast heating), and poor capillary packing. Calibration errors or a failing temperature sensor can also cause anomalies in readings. Use two samples-one known and one unknown-to isolate whether the problem is the sample or the instrument. Troubleshooting by reviewing prep, settings, and system performance ensures reliable outcomes.

5. How do optical or video detection systems enhance melting point analysis in melting point apparatus ?

advanced melting point apparatus instruments include built-in cameras that record videos or capture images of the melting tube. This allows software to automatically detect the start and end of melting, reducing operator subjectivity and improving precision. Video playback on a touchscreen offers visual confirmation and auditability. Multichannel systems can simultaneously analyse several samples. These features support compliance requirements like 21??11 with timestamped data and user logs, and streamline workflows in high-throughput or regulated labs.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.