Introduction

Horizontal operates within a working temperature range of 105°C to 139°C, ensuring precise sterilization. With a sturdy chamber design pressure of –0.1/0.5 MPa, this autoclave guarantees durability and safety. Its advanced and control system offers intuitive operation and real-time monitoring. It allows programmable sterilization and drying times, providing flexibility across various load types. It is ideal for modern laboratory settings requiring reliable and high-capacity sterilization.

It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.

Applications

Our Horizontal Laboratory Autoclave is suitable for sterilizing high temperature- and high pressure-resisting items, including unwrapped or wrapped instruments, dressings, rubber materials, liquids, implantable instruments, porous items, and hollow instruments.

Specifications

Chamber Capacity 450 Liters
Door Type Double Door
Control System + + Built-in Printer
Display 7.0-inch Color Touchscreen
Design Pressure –0.1 / 0.5 MPa
Working Pressure Range 0 to 0.25 MPa
Safety Valve Opening Pressure 0.28 MPa
Design Temperature 150°C
Working Temperature Range 105°C to 139°C
Temperature Control Accuracy ≤ ± 0.2°C
Temperature Display Accuracy 0.1°C
Temperature Equilibrium ≤ ± 0.5°C
Sterilization Time Range 0 to 999 min
Drying Time Range 0 to 999 min
Vacuum Rate –97 kPa
Vacuum System Liquid Ring Vacuum Pump (Pre & Post)
Steam Consumption per Cycle 22 kg
Water Consumption per Cycle 180 kg
Power Consumption 32 kW
Chamber Size (W × D × H) 652 × 690 × 1000 mm
Outer Dimensions (W × D × H) 1350 × 1950 × 1350 mm
Net Weight 950 kg

Features

Large Chamber Capacity

Double Door Design

Advanced Control System

User-Friendly Interface

Precise Temperature Control

Reliable Pressure System

Efficient Vacuum System

Programmable Cycles

Optimized Resource Use

Durable Construction

Compact Footprint

Heavy-Duty Build

FAQs

1. What is the working temperature range of the Horizontal Laboratory Autoclave , and why is it important for sterilization?

The Horizontal Laboratory Autoclave operates within a temperature range of 105°C to 139°C, with a design temperature of 150°C. This broad range ensures that it can efficiently sterilize various load types, ranging from wrapped and unwrapped instruments to rubber, porous items, liquids, and implantable medical devices. The precise temperature control accuracy (less than equal to ± 0.2°C) and equilibrium (less than equal to ± 0.5°C) ensure uniform heat distribution, which is critical for reliable and repeatable sterilization outcomes in laboratory and clinical environments.

2. What advanced control features does the Horizontal Laboratory Autoclave offer for optimized sterilization processes?

The Horizontal Laboratory Autoclave is equipped with a + control system and a 7.0-inch color touchscreen display, offering intuitive operation and real-time monitoring. Users can easily program sterilization and drying cycles (from 0 to 999 minutes), allowing customization based on specific sterilization needs. The built-in printer ensures proper documentation and traceability of sterilization records, which is essential for compliance in medical, pharmaceutical, and research environments.

3. How does the Horizontal Laboratory Autoclave ensure effective air removal and drying during the sterilization cycle?

The Horizontal Laboratory Autoclave features a powerful liquid ring vacuum pump system that supports both pre-vacuum and post-vacuum phases. This dual-phase vacuum process ensures the complete removal of air before steam injection, which enhances steam penetration in porous and hollow instruments. The post-vacuum phase contributes to effective drying, especially for wrapped instruments, ensuring sterility and readiness for immediate use or packaging.

4. Is the Horizontal Laboratory Autoclave suitable for sterilizing delicate or sensitive materials?

Yes, the Horizontal Laboratory Autoclave is ideal for sterilizing both delicate and high-resistance materials. The programmable temperature and pressure settings, along with accurate control and gentle vacuum cycles, make it suitable for a variety of sensitive items such as implantable devices, rubber components, and liquids. The temperature display accuracy of 0.1°C and the vacuum rate of –97 kPa provide the precise environment needed to ensure safety and integrity during sterilization.

5. What makes the Horizontal Laboratory Autoclave a reliable choice for high-volume laboratory or clinical use?

The Horizontal Laboratory Autoclave has a lar ge 450-liter chamber capacity and a double-door design for contamination control in pass-through applications such as CSSDs (Central Sterile Supply Departments) or cleanrooms. Its durable stainless-steel construction, compact footprint, and heavy-duty build make it robust enough for continuous operation. With a steam consumption of 22 kg per cycle and water usage of 180 kg, it is engineered to balance performance with resource efficiency. Additionally, its power consumption of 32 kW supports high-throughput sterilization without compromising precision.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.