Introduction
Horizontal operate within a temperature range of 105°C to 139°C, ensuring uniform and accurate sterilization. It features a user-friendly 7.0-inch color touchscreen display and a robust double-door to ensure optimal contamination control. Its powerful liquid ring vacuum pump supports both pre and post-vacuum phases, ensuring effective air removal. Its compact design makes it an ideal solution for modern sterile processing facilities.
It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.Applications
Our Horizontal Laboratory Autoclave is specifically designed for sterilizing items that can withstand high temperatures and pressures, including both unwrapped and wrapped instruments, surgical dressings, rubber materials, liquids, plant-in instruments, as well as porous and hollow items.
Specifications
| Chamber Capacity | 400 Liters |
| Door Type | Double Door |
| Control System | + + Built-in Printer |
| Display | 7.0-inch Color Touchscreen |
| Design Pressure | –0.1 / 0.5 MPa |
| Working Pressure Range | 0 to 0.25 MPa |
| Safety Valve Opening Pressure | 0.28 MPa |
| Design Temperature | 150°C |
| Working Temperature Range | 105°C to 139°C |
| Temperature Control Accuracy | ≤ ± 0.2°C |
| Temperature Display Accuracy | 0.1°C |
| Temperature Equilibrium | ≤ ± 0.5°C |
| Sterilization Time Range | 0 to 999 min |
| Drying Time Range | 0 to 999 min |
| Vacuum Rate | –97 kPa |
| Vacuum System | Liquid Ring Vacuum Pump (Pre & Post) |
| Steam Consumption per Cycle | 21 kg |
| Water Consumption per Cycle | 170 kg |
| Power Consumption | 32 kW |
| Chamber Size (W × D × H) | 652 × 690 × 850 mm |
| Outer Dimensions (W × D × H) | 1350 × 1950 × 1200 mm |
| Net Weight | 920 kg |
Features
Large Chamber Capacity
Double Door Design
Advanced Control System
User-Friendly Interface
Wide Temperature and Pressure Range
High Temperature Accuracy
Effective Vacuum System
Customizable Cycles
Efficient Resource Use
Durable and Compact Design
Built-in Safety Measures
FAQs
1. What makes the Horizontal Laboratory Autoclave suitable for high-capacity sterilization needs in modern laboratories and healthcare settings?
The Horizontal Laboratory Autoclave is specifically engineered to meet the high-capacity sterilization requirements of laboratories, CSSDs, pharmaceutical environments, and research institutions. With a 400-liter chamber, it can handle large volumes of items in a single cycle, improving throughput and efficiency. Its double-door design enhances contamination control by preventing cross-contamination between sterile and non-sterile areas. The unit also includes a powerful liquid ring vacuum pump for effective pre- and post-vacuum processes, which ensures complete air removal and thorough drying, even for complex loads like hollow instruments and porous materials.
2. How does the advanced vacuum system in the Horizontal Laboratory Autoclave improve sterilization outcomes?
The Horizontal Laboratory Autoclave features a liquid ring vacuum pump system that supports both pre- and post-vacuum phases. This dual-phase system ensures effective air removal before sterilization and efficient drying after sterilization, which is crucial for porous loads, wrapped instruments, and hollow items. By eliminating air pockets that can interfere with steam penetration, it guarantees uniform steam distribution, leading to reliable sterilization outcomes and compliance with high-standard sterilization protocols.
3. What are the key control and monitoring features of the Horizontal Laboratory Autoclave ?
The autoclave is equipped with an advanced + control system and a 7.0-inch color touchscreen that provides an intuitive and user-friendly interface. It allows users to customize and program sterilization and drying cycles based on specific requirements. The built-in printer offers real-time documentation of each cycle, ensuring traceability and compliance with regulatory standards. Additionally, the autoclave provides precise temperature control accuracy of ±0.2°C, display accuracy of 0.1°C, and temperature equilibrium of ±0.5°C, making it highly dependable for sensitive sterilization applications.
4. What types of materials and instruments can be sterilized using the Horizontal Laboratory Autoclave ?
The Horizontal Laboratory Autoclave is designed to sterilize a wide range of items that are resistant to high temperatures and pressures. These include: • Wrapped and unwrapped surgical instruments • Rubber items and surgical dressings • Liquids in appropriate containers • Porous materials and hollow instruments • Plant-in tools used in research or lab settings This versatility makes it ideal for medical, pharmaceutical, food testing, research laboratories, and other scientific institutions where diverse sterilization loads are common.
5. How energy-efficient and resource-conscious is the Horizontal Laboratory Autoclave during operation?
Despite its large capacity and high performance, the Horizontal Laboratory Autoclave is designed for efficient resource utilization. Each cycle consumes approximately 21 kg of steam and 170 kg of water, which is optimized for its 400-liter chamber size. Its 32 kW power consumption is balanced by its efficiency in completing comprehensive sterilization cycles in programmable time ranges (0 to 999 minutes). This helps institutions maintain operational efficiency while managing energy and water usage effectively.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.