Introduction
Horizontal features a 200-liter capacity and is equipped with advanced a robust double-door design to prevent cross-contamination. It maintains a working pressure range of 0 to 0.25 MPa and a design temperature of 150°C. It supports a flexible sterilization and drying time range, ensuring adaptability across a variety of load types. Its spacious chamber and sturdy build ensure reliable performance, making it ideal for high-demand sterilization environments.
It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.Applications
Our Horizontal Laboratory Autoclave effectively sterilizes a wide range of materials including unwrapped or wrapped instruments, glassware, rubber products, liquids, porous loads, and hollow instruments.
Specifications
| Chamber Capacity | 200 Liters |
| Door Type | Double Door |
| Control System | + + Built-in Printer |
| Display | 7.0-inch Color Touchscreen |
| Design Pressure | –0.1 / 0.5 MPa |
| Working Pressure Range | 0 to 0.25 MPa |
| Safety Valve Opening Pressure | 0.28 MPa |
| Design Temperature | 150°C |
| Working Temperature Range | 105°C to 139°C |
| Temperature Control Accuracy | ≤ ± 0.2°C |
| Temperature Display Accuracy | 0.1°C |
| Temperature Equilibrium | ≤ ± 0.5°C |
| Sterilization Time Range | 0 to 999 min |
| Drying Time Range | 0 to 999 min |
| Vacuum Rate | –97 kPa |
| Vacuum System | Liquid Ring Vacuum Pump (Pre & Post) |
| Steam Consumption per Cycle | 14 kg |
| Water Consumption per Cycle | 110 kg |
| Power Consumption | 22 kW |
| Chamber Size (W × D × H) | 550 × 550 × 750 mm |
| Outer Dimensions (W × D × H) | 1290 × 1850 × 1200 mm |
| Net Weight | 650 kg |
Features
Double Door Contamination Control
Intelligent + System
Touchscreen Interface
High-Precision Temperature Regulation
Adjustable Sterilization & Drying Time
Advanced Vacuum System
Built-in Safety Mechanisms
Efficient Resource Consumption
Heavy-Duty Durable Construction
FAQs
1. What are the key features that make the Horizontal Laboratory Autoclave suitable for high-demand sterilization tasks?
The Horizontal Laboratory Autoclave is engineered to handle intensive sterilization workloads efficiently. Its 200-liter chamber capacity allows large batch processing, while its robust double-door design minimizes the risk of cross-contamination—making it ideal for environments like hospitals, pharmaceutical labs, and research institutions. With a design temperature of 150°C and a working range of 105°C to 139°C, it ensures effective sterilization. The + system and 7.0-inch touchscreen provide intuitive control and real-time monitoring. Additionally, its liquid ring vacuum pump supports both pre and post-vacuum cycles, ensuring thorough steam penetration and drying for complex loads.
2. How does the + control system in the Horizontal Laboratory Autoclave enhance user experience and sterilization accuracy?
The intelligent + control system in the provides a seamless interface for managing sterilization parameters. The 7.0-inch color touchscreen allows operators to easily program and monitor sterilization cycles, adjust temperature, pressure, and time settings, and track real-time performance data. The built-in printer supports documentation, which is essential for maintaining sterilization logs in medical, research, and industrial settings. The system also includes safety interlocks and error alerts to ensure safe and uninterrupted operation.
3. What safety features are integrated into the Horizontal Laboratory Autoclave to ensure secure operation?
Safety is a top priority in the design of the Horizontal Laboratory Autoclave . It comes with built-in safety mechanisms, including a safety valve that opens at 0.28 MPa to relieve excess pressure. The temperature control accuracy of ±0.2°C and a display accuracy of 0.1°C ensure precise monitoring. The temperature equilibrium is maintained at less than equal to ± 0.5°C, preventing temperature spikes. Additionally, the double-door system is engineered to prevent accidental opening during cycles, reducing contamination and injury risks.
4. How does the vacuum system in the Horizontal Laboratory Autoclave improve sterilization efficiency?
The features a liquid ring vacuum pump capable of executing both pre-vacuum and post-vacuum functions. The vacuum rate reaches –97 kPa, allowing the autoclave to remove air effectively before steam injection, which is essential for sterilizing hollow and porous items. Post-vacuum cycles facilitate enhanced drying, making the equipment especially suitable for wrapped instruments and materials where moisture retention must be minimized.
5. In what types of environments is the Horizontal Laboratory Autoclave most effectively used?
Thanks to its high-capacity chamber, advanced sterilization control, and robust safety features, the Horizontal Laboratory Autoclave is perfect for use in research laboratories, pharmaceutical manufacturing units, clinical hospitals, universities, and food or chemical testing facilities. It is ideal for sterilizing instruments, labware, rubber, glass, liquids, porous materials, and more. The double-door design makes it especially suitable for controlled environments such as cleanrooms or central sterile services departments ().
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.