Introduction

Horizontal operates within a temperature range of 105°C to 139°C. With a design pressure of –0.1/0.5 MPa, it provides safe and reliable performance. It features a robust single-door design and a fully automated control system integrated for real-time monitoring. Its liquid ring vacuum pump supports both pre and post vacuum cycles, ensuring deep sterilization. It is designed with a spacious chamber, combining durability with advanced sterilization performance.

It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.

Applications

Our Horizontal Laboratory Autoclave is specifically designed for the sterilization of items that can withstand high temperatures and pressures. This includes both unwrapped and wrapped instruments, surgical dressings, rubber materials, liquids, implantable instruments, as well as porous and hollow items. 

Specifications

Chamber Capacity 200 Liters
Door Type Single Door
Control System + + Built-in Printer
Display 7.0-inch Color Touchscreen
Design Pressure –0.1 / 0.5 MPa
Working Pressure Range 0 to 0.25 MPa
Safety Valve Opening Pressure 0.28 MPa
Design Temperature 150°C
Working Temperature Range 105°C to 139°C
Temperature Control Accuracy ≤ ± 0.2°C
Temperature Display Accuracy 0.1°C
Temperature Equilibrium ≤ ± 0.5°C
Sterilization Time Range 0 to 999 min
Drying Time Range 0 to 999 min
Vacuum Rate –97 kPa
Vacuum System Liquid Ring Vacuum Pump (Pre & Post)
Steam Consumption per Cycle 14 kg
Water Consumption per Cycle 110 kg
Power Consumption 22 kW
Chamber Size (W × D × H) 550 × 550 × 750 mm
Outer Dimensions (W × D × H) 1290 × 1850 × 1200 mm
Net Weight 650 kg

Features

Large Chamber Capacity

Advanced + Control System

User-Friendly Touchscreen Display

High Temperature and Pressure Accuracy

Adjustable Sterilization and Drying Times

Efficient Liquid Ring Vacuum System

Low Steam and Water Consumption per Cycle

High Power Efficiency 

Robust Single-Door Design

Built-in Printer 

Durable Construction

Enhanced Safety Features

FAQs

1. What are the key features that distinguish the Horizontal Laboratory Autoclave from other laboratory autoclaves?

The Horizontal Laboratory Autoclave stands out due to its integration of a highly advanced + control system, which enables automated real-time monitoring and precise control over sterilization parameters. It operates within a temperature range of 105°C to 139°C with a high degree of accuracy (less than equal to ± 0.2°C) and supports customizable sterilization and drying times. The 7.0-inch color touchscreen provides intuitive interaction, and the liquid ring vacuum system ensures effective pre- and post-vacuum processes for deep sterilization. Its single-door design, durable stainless-steel construction, low resource consumption per cycle, and built-in safety features further enhance its reliability and performance.

2. How does the Horizontal Laboratory Autoclave ensure safety during high-pressure and high-temperature operations?

Safety is a central design element in the Horizontal Laboratory Autoclave . The system includes a safety valve with an opening pressure of 0.28 MPa to release excess pressure automatically. Additionally, the autoclave is equipped with precise temperature and pressure control mechanisms to avoid system overloading. The temperature equilibrium is maintained within ± 0.5°C, ensuring consistent sterilization conditions. A robust and secure single-door mechanism helps maintain chamber integrity, while built-in alarms and interlocks protect against improper operation or unsafe conditions during use.

3. What types of materials or instruments can be sterilized using the Horizontal Laboratory Autoclave ?

The Horizontal Laboratory Autoclave is designed to sterilize a broad range of items that are resistant to high temperatures and pressures. This includes wrapped and unwrapped surgical instruments, medical dressings, rubber products, liquids in sealed or open containers, implantable devices, porous loads, and hollow instruments. It is suitable for demanding applications across medical, pharmaceutical, research, and industrial laboratories, where thorough sterilization is critical.

4. How does the liquid ring vacuum system in the Horizontal Laboratory Autoclave enhance sterilization performance?

The integrated liquid ring vacuum pump in the Horizontal Laboratory Autoclave supports both pre-vacuum and post-vacuum phases. During pre-vacuum, it removes air from the chamber to enable better steam penetration, especially in porous or hollow loads. Post-vacuum helps eliminate remaining steam and moisture after sterilization, significantly improving drying efficiency. With a vacuum rate of –97 kPa, the system ensures complete air evacuation and deep sterilization, which is particularly crucial for instruments with complex geometries.

5. What are the installation space requirements for the Horizontal Laboratory Autoclave ?

To accommodate the Horizontal Laboratory Autoclave , users should consider its outer dimensions of 1290 × 1850 × 1200 mm (W × D × H). The chamber size is 550 × 550 × 750 mm, providing a capacity of 200 liters, which is ample for high-throughput sterilization cycles. Additionally, provisions for power supply (22 kW), steam and water connections, and proper ventilation are essential to ensure safe and optimal operation. It weighs 650 kg, so proper flooring and transport access must be factored in during planning.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.