Introduction
Mini Centrifuge maximum speed of 12000 rpm, ensuring efficient sample processing. It features precise time settings for accurate results. The design allows for easy sample loading. Its quick-stop braking system ensures safety. Our mini centrifuge has high-strength rotor material for durability.
It utilizes high-speed rotation to separate components of different densities, widely used in biological, medical, and chemical laboratories. The unit is equipped with safety protection systems to ensure operator safety during high-speed operation.Applications
Mini Centrifuge Mini Centrifuge is a compact, portable centrifuge designed for quick spin-downs and micro-sample separation. It is ideal for small labs, educational use, and routine tasks like tube centrifugation and sample clarification.
Specifications
| Maximum Speed | 12000 rpm |
| Maximum | 5800 g |
| Capacity | 8 × 2.0 ml/1.5 ml/0.5ml/0.2ml 2 × 8 × 0.2 ml tube |
| Noise | ≤ 45 dB |
| Voltage | AC 220/110 50 Hz /60 Hz |
| Power Consumption | 30 W |
| Dimensions (L × W × H) | 161 × 175 × 121 mm |
Features
Low vibration design
Chemical-resistant housing
Ventilated motor system
Precision speed regulation
Noise-reduction technology
FAQs
1. What is the maximum sample volume that can be processed in the centrifuge?
The maximum sample volume depends on the type of rotor used with the centrifuge. Typical rotors can accommodate sample volumes ranging from 0.2 mL (microcentrifuge tubes) to 50 mL (conical tubes) or larger for specialized rotors. It is important to check the centrifuge's specifications and rotor compatibility to ensure that the sample volume does not exceed the recommended limits, which could affect centrifugation efficiency and safety.
2. How to balance the centrifuge before operation?
Proper balancing is critical for safe and effective centrifuge operation: 1) Ensure that all sample tubes have the same volume and weight; 2) Place the tubes symmetrically in the rotor, opposite each other; 3) For odd numbers of samples, use a balance tube filled with the same volume of appropriate solution; 4) Check that the rotor is properly seated and secured in the centrifuge; 5) Avoid overloading the rotor beyond its maximum capacity.
3. What is the difference between relative centrifugal force (RCF) and revolutions per minute (RPM)?
RCF is a measure of the centrifugal force applied to the sample, expressed in multiples of gravity (x g), and depends on both the RPM and the radius of the rotor. RPM is a measure of the rotor's rotation speed in revolutions per minute. The relationship between RCF and RPM is given by the formula: RCF = 1.118 × 10^-5 × r × RPM² (where r is the rotor radius in centimeters). For most applications, RCF is the preferred parameter as it directly relates to the separation efficiency, regardless of rotor size.
4. How to maintain the centrifuge to ensure long service life?
Regular maintenance includes: 1) Cleaning the rotor and chamber after each use to remove sample spills and debris; 2) Inspecting the rotor for cracks, corrosion, or wear before each use; 3) Lubricating moving parts according to the manufacturer's recommendations; 4) Calibrating the speed and temperature controls annually or after major service; 5) Ensuring proper ventilation around the centrifuge to prevent overheating; 6) Storing the centrifuge in a clean, dry environment when not in use.
5. What safety precautions should be taken when using the centrifuge?
Important safety precautions include: 1) Always balance the sample tubes properly before operation; 2) Ensure the rotor is correctly installed and secured; 3) Do not open the centrifuge lid while the rotor is still spinning; 4) Use appropriate personal protective equipment (gloves, goggles) when handling samples and cleaning the equipment; 5) Avoid overloading the centrifuge beyond its maximum capacity; 6) Regularly inspect the centrifuge for any signs of damage or malfunction and discontinue use if any issues are found.
1. What is the Mini Centrifuge used for?
The It Mini Centrifuge is a compact and efficient laboratory device primarily used for rapid centrifugation of small-volume biological samples. It's ideal for quick spin-downs of microtubes, microfiltration processes, and sample collection after vortexing or thawing. With its small footprint, it's especially suited for personal workstations, allowing researchers to conduct essential sample preparation steps efficiently. The ensures reliable performance for routine tasks like / isolation, protein separation, and buffer exchanges. It's also a favored choice in clinical, educational, and field laboratories due to its user-friendly operation. The model supports fast acceleration and deceleration to streamline workflows. It has designed this unit with the versatility and convenience needed for modern lab routines. Its portability and efficiency make it a daily-use essential for molecular and clinical labs.
2. What are the typical speed and capacity specifications of the Mini Centrifuge ?
The It Mini Centrifuge typically operates at fixed speeds ranging between 4000 and 7000 , depending on the configuration, which allows for rapid separation of small biological samples. It generally accommodates 6 to 8 microcentrifuge tubes, supporting volumes such as 1.5 mL or 2.0 mL. Some versions also include adapters for 0.5 mL tubes or strip tubes, increasing its versatility. Despite its compact size, the provides a significant centrifugal force ideal for routine laboratory protocols. Its rotor is balanced for minimal vibration, enhancing safety and consistency. It ensures that even with limited capacity, the centrifuge delivers high efficiency in spin-down tasks. It is perfect for researchers needing quick separation without the bulk of a full-sized centrifuge. The fixed-speed operation reduces complexity and makes it user-friendly for new users. Overall, the combines speed, safety, and space-saving benefits for small sample processing.
3. Is the Mini Centrifuge safe for everyday laboratory use?
Yes, It Mini Centrifuge is built with multiple safety features to ensure secure operation in laboratory environments. It features a lid-locking system that prevents the rotor from spinning unless the lid is securely closed. When the lid is opened, the centrifuge halts immediately to avoid user injury. The unit also includes imbalance detection, which stops the device from operating under uneven load conditions, thereby protecting the motor and samples. Anti-slip feet provide additional stability during operation. It constructs the outer casing from high-strength materials to resist wear and minor spills. The device operates with minimal noise, contributing to a more comfortable workspace. These safety features are particularly beneficial in educational settings, where multiple users may handle the device. focus on intuitive design and robust safety makes the a reliable and safe tool for routine lab work.
4. Can different rotor types be used with the Mini Centrifuge ?
Yes, It Mini Centrifuge offers compatibility with various rotor types to accommodate different experimental needs. Users can easily switch between rotors designed for microcentrifuge tubes, strip tubes, and smaller tube adapters without using tools. This modularity allows labs to perform a wide range of protocols using a single instrument. The rotors are designed for easy insertion and removal, ensuring a seamless user experience. It ensures that all compatible rotors maintain balance and rotational safety. Some rotors are autoclavable, allowing for easy sterilization between uses. This rotor flexibility helps the serve multiple departments or research teams within a single lab. Users should always follow the manual instructions when swapping rotors to maintain optimal performance. With engineering, the rotor system in maintains both flexibility and mechanical stability.