Introduction

Horizontal offers a working temperature range from 105°C to 136°C and precise temperature control with ±0.1°C accuracy. Its double-door design enhances workflow, while its 7-inch and post-vacuum systems, and vacuum drying functionality, ensures thorough sterilization and drying of instruments. This autoclave is compact yet powerful, combining high performance, user-friendly operation, and advanced sterilization technology in a durable design.

It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.

Applications

Our Horizontal Laboratory Autoclave is ideal for a wide range of sterilization needs in medical, pharmaceutical, research, and laboratory settings. Its double-door design makes it especially valuable in cleanroom environments where contamination control is critical.

Specifications

Capacity 300 L
Design Pressure -0.1 / 0.25 MPa
Max Working Pressure 0.23 MPa
Design Temperature 139°C
Working Temperature Range 105°C to 136°C
Temperature Accuracy ±0.1°C
Sterilization Time Range 0 to 99 min
Drying Time Range 0 to 99 min
Vacuum Rate -0.081 MPa
Door Type Double doors
Control System + + Built-in Printer
Display 7-inch color touch screen
Vacuum System Pre-vacuum and post-vacuum
Steam Generator Built-in steam generator
Loading Type Sterilization tray
Water Tank Included
Drying Function Vacuum drying
Voltage 380V, 50/60Hz
Power Consumption 15 kW
Chamber Size 300L / Ø600 × 1080 mm
Outer Dimensions 1520 × 850 × 1850 mm
Packing Dimensions 1680 × 1080 × 2100 mm
Net Weight 580 kg
Gross Weight 680 kg

Features

Large Sterilization Chamber

Double-Door Design 

Pre-Vacuum and Post-Vacuum System

Built-in Steam Generator

Vacuum Drying Function

Touch Screen Display

+ Control System 

Built-in Printer

Wide Working Temperature Range 

High Temperature Accuracy 

Adjustable Sterilization and Drying Time 

Integrated Water Tank

Efficient Power Consumption 

Sterilization Tray Loading Type

Strong Vacuum Rate 

FAQs

1. What is the working temperature range and temperature accuracy of the Horizontal Laboratory Autoclave ?

The Horizontal Laboratory Autoclave operates within a wide working temperature range of 105°C to 136°C, ensuring compatibility with a variety of sterilization protocols. It offers exceptional temperature accuracy of ±0.1°C, which is critical for sensitive laboratory instruments and pharmaceutical applications. This precision ensures reliable and repeatable sterilization outcomes.

2. How does the double-door design of the Horizontal Laboratory Autoclave benefit cleanroom or controlled environments?

The double-door design of the is specifically engineered for pass-through sterilization, allowing one side of the autoclave to open into the sterile environment while the other opens into a non-sterile area. This design prevents cross-contamination, making it ideal for cleanrooms, pharmaceutical production areas, and laboratories that require strict contamination control protocols.

3. What types of sterilization cycles and drying capabilities does the Horizontal Laboratory Autoclave support?

The Horizontal Laboratory Autoclave supports adjustable sterilization and drying times, each ranging from 0 to 99 minutes, offering flexibility for diverse sterilization needs. It features pre-vacuum and post-vacuum systems to eliminate air pockets and enhance steam penetration, followed by a vacuum drying function that ensures thoroughly dried instruments after each cycle. These systems work together to deliver superior sterilization efficiency and complete drying, particularly for porous loads and wrapped items.

4. What are the control and monitoring features of the Horizontal Laboratory Autoclave ?

The is equipped with a (Programmable Logic Controller) and (Human-Machine Interface) system for intelligent automation and precise control of each sterilization phase. The autoclave also includes a 7-inch color touchscreen for intuitive user operation and real-time cycle monitoring. Additionally, it comes with a built-in printer to provide automated documentation of sterilization parameters, supporting traceability and regulatory compliance.

5. How large is the chamber in the Horizontal Laboratory Autoclave , and what type of loading system does it use?

The features a high-capacity 300-liter chamber with dimensions of Ø600 × 1080 mm, making it ideal for sterilizing large loads or bulky instruments. It uses a sterilization tray loading type, which allows easy organization and optimal use of space within the chamber. The generous capacity, combined with efficient sterilization cycles, makes the suitable for high-throughput environments such as hospitals, pharmaceutical production, and research laboratories.

Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.