Introduction
Horizontal features a robust design pressure of -0.1/0.25 MPa and a maximum working pressure of 0.23 MPa. It operates efficiently within a working temperature range of 105°C to 136°C and maintains exceptional temperature accuracy. It is equipped with advanced a control system, a color touch screen, and a built-in printer, ensuring user-friendly operation and accurate data recording. Its double-door structure enhances contamination control, while the included water tank and sterilization tray simplify workflow.
It uses high-temperature and high-pressure steam to achieve effective sterilization of laboratory equipment, media, and waste. The advanced control system ensures thorough sterilization while preventing overheating or pressure buildup.Applications
Our Horizontal Laboratory Autoclave is ideally suited for a wide range of sterilization needs in laboratories, hospitals, pharmaceutical industries, research institutions, and microbiology labs.
Specifications
| Capacity | 200 L |
| Design Pressure | -0.1 / 0.25 MPa |
| Max Working Pressure | 0.23 MPa |
| Design Temperature | 139°C |
| Working Temperature Range | 105°C to 136°C |
| Temperature Accuracy | ±0.1°C |
| Sterilization Time Range | 0 to 99 min |
| Drying Time Range | 0 to 99 min |
| Vacuum Rate | -0.081 MPa |
| Door Type | Double doors |
| Control System | + + Built-in Printer |
| Display | 7-inch color touch screen |
| Vacuum System | Pre-vacuum and post-vacuum |
| Steam Generator | Built-in steam generator |
| Loading Type | Sterilization tray |
| Water Tank | Included |
| Drying Function | Vacuum drying |
| Voltage | 380V, 50/60Hz |
| Power Consumption | 12 kW |
| Chamber Size | 200L / Ø515 × 1000 mm |
| Outer Dimensions | 1400 × 760 × 1750 mm |
| Packing Dimensions | 1560 × 910 × 1880 mm |
| Net Weight | 470 kg |
| Gross Weight | 560 kg |
Features
Large Capacity Chamber
Wide Temperature Range
High Temperature Accuracy
Strong Pressure Handling
Advanced Vacuum System
User-Friendly Interface
Efficient Drying Function
Built-in Steam Generator
Double-Door Safety Design
Sterilization and Drying Time Adjustment
Integrated Water Tank
High Power Performance
Durable and Compact Design
Easy Loading System
FAQs
1. What is the working temperature range of the Horizontal Laboratory Autoclave , and how does it impact sterilization efficiency?
The Horizontal Laboratory Autoclave operates within a precise temperature range of 105°C to 136°C, which is critical for effectively sterilizing a variety of laboratory, pharmaceutical, and hospital-grade instruments. This wide temperature range, paired with its ±0.1°C temperature accuracy, ensures that even heat-sensitive materials are sterilized without risk of under or over-processing. The ability to maintain this level of precision boosts sterilization reliability across different load types and volumes.
2. How does the double-door design of the Horizontal Laboratory Autoclave help prevent cross-contamination?
The autoclave features a double-door safety design, which serves a vital role in controlled environments like cleanrooms or labs. This design separates the "sterile" and "non-sterile" zones by allowing materials to enter through one side and exit through another after sterilization. Such a setup significantly reduces the risk of cross-contamination, especially in high-stakes environments like pharmaceutical production and hospital operating rooms.
3. What control and monitoring systems are integrated into the Horizontal Laboratory Autoclave for user-friendly operation?
The Horizontal Laboratory Autoclave is equipped with a control system integrated with an interface and a 7-inch color touchscreen. This intuitive control panel allows users to set, monitor, and adjust parameters like sterilization time, drying duration, and temperature with ease. Additionally, the built-in printer ensures that cycle data and sterilization logs are accurately recorded and documented for compliance and traceability.
4. How does the Horizontal Laboratory Autoclave achieve thorough drying after the sterilization process?
Drying is a crucial post-sterilization step, and the autoclave addresses this with its vacuum drying function, which removes residual moisture from instruments after steam sterilization. The advanced pre-vacuum and post-vacuum system enhances drying efficiency by evacuating air before sterilization and after the cycle ends, thus ensuring that instruments are sterile, dry, and ready for immediate use or packaging.
5. Is the Horizontal Laboratory Autoclave suitable for large-scale operations, and what is its capacity?
Yes, the Horizontal Laboratory Autoclave is designed to meet high-throughput sterilization demands. It features a large 200-liter chamber with dimensions of Ø515 × 1000 mm, making it ideal for sterilizing bulky instruments, glassware, or multiple loads simultaneously. This makes the unit a reliable choice for hospitals, pharmaceutical industries, research labs, and microbiology facilities that require consistent and large-scale sterilization.
Tips: For more details, quotes and customized solutions, please contact us anytime. We’re always ready to serve you professionally.

